4.4

WHAT IF THE APPLIANCE IS DUE ITS ANNUAL
SERVICE
Advice for tenants only
Your landlord should arrange for servicing.
Advice for homeowners
Please contact Vokera Customer Service (0870
333 0220 (UK) or 05655057 (ROI)
 if you would
prefer a Vokera service engineer or agent to
service your appliance. Alternatively your local
CORGI registered engineer may be able to service
the appliance for you.

4.5

WHAT IF I NEED TO CALL AN ENGINEER
If you think your boiler may have developed a fault,
please contact your installer or Vokera Customer
Services (0870 333 0220 (UK) or 05655057 (ROI)
have all your details to hand including full address
and postcode, relevant contact numbers, and your
completed appliance log book.

WHAT IF...

4.1

WHAT IF I SUSPECT A GAS LEAK
If you suspect a gas leak, turn off the gas supply
at the gas meter and contact your installer or local
gas supplier. If you require further advice please
contact your nearest Vokera office.

4.2

WHAT IF I HAVE FREQUENTLY TO TOP-UP
THE SYSTEM
If the system regularly requires topping-up, it may
be indicative of a leak. Please contact your in-
staller and ask him to inspect the system.

4.3

WHAT IF THE RESET LIGHT IS ON
If the Red LED light is illuminated, it indicates that
the boiler has failed to ignite or has detected a
possible fault. When this happens the boiler auto-
matically shuts down and requires to be reset
manually (see 3.2).

SETTING THE VOKERA...

5.1

SETTING THE VOKERA MECHANICAL CLOCK
If your boiler has been installed with the Vokera
mechanical clock, it can be used  and adjusted as
follows:

Setting the time
The time of day can be set by grasping the outer edge of the
black dial and turning it in a clockwise direction until the cor-
rect time is in line with the white pointer.

Setting the “switching times”
The “ON” periods are set by sliding the black tappets, adja-
cent to the time periods required, to the outer edge of the dial.

The tappets that remain at the centre of the dial will be the
“OFF” periods.

The smallest switching time (ON or OFF) is 15 minutes.

To select “AUTO” mode move the selector switch in central
position.

To select “ON” mode move the selector switch in the bottom
position.

To select “OFF” mode move the selector switch in the upper
position.

5.2

THE VOKERA DIGITAL PROGRAMMER
If your boiler has been installed with the Vokera
twin channel programmer, it can be used and
adjusted as follows:

FEATURES

Backlight display

Built-in standard programme

7-day battery back-up

Manual over-ride

2-ON/2-OFF periods for each channel (Heating/
Hot water).

5.2.1

SETTING THE DAY & TIME

Press and hold the 

 button for 4-seconds or

until the clock display flashes.

Press either the + or - button to increase or
decrease the displayed value of minutes to the

correct (actual) time and press 

 to confirm.

Press either the + or - button to increase or
decrease the displayed value of hours to the

correct (actual) time and press 

 to confirm.

Press either the + or - button to increase or
decrease the displayed day to the correct (ac-

tual) day of the week and press 

 to confirm.

5.2.2

CLOCK CHANGE
To accommodate any change from summer time
to winter time, simply press and hold either the +
or - button to advance or retard the hours value by
one hour.

AUTO

ON

OFF

Содержание Mynute HE

Страница 1: ...INSTRUCTIONS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK M...

Страница 2: ...erson responsible for the property in which the appliance is located installed A replacement copy can be obtained from Vokera customer services Contents Introduction Page Dear customer 2 Do s and don...

Страница 3: ...ated water to your radiators and hot water tank The central heating and hot water is controlled via a time clock or programmer and any thermo stats that your installer may have fitted The boiler will...

Страница 4: ...temperature of the boiler however in certain circumstances a fault code or specific characters will be displayed to indicate that the appliance is performing a specific func tion 1 Pressuregauge 2 Mo...

Страница 5: ...ndardCH systems and between 20 C 45 C under floor CH systems The 2 digit LED display normally shows the operatingtemperatureoftheappliance howeverit can also display additional characters or flashing...

Страница 6: ...re occurs AL21 Reset appliance Call engineer if fault re occurs AL26 Reset appliance Call engineer if fault re occurs AL28 Reset appliance Call engineer if fault re occurs AL34 Reset appliance Call e...

Страница 7: ...he Vokera mechanical clock it can be used and adjusted as follows Setting the time The time of day can be set by grasping the outer edge of the black dial and turning it in a clockwise direction until...

Страница 8: ...for C1 Toadjustorre programmethedefaultprogramme please proceed as follows Press and hold the P button for 3 seconds the displaywillshowPROfor1 secondtosignalthat the programmer is now ready to be re...

Страница 9: ...Supplied By www heating spares co Tel 0161 620 6677 9...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 12: ...ries vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 099 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve t...

Отзывы: