5.2.3

SETTING THE VOKERA MECHANICAL CLOCK
The programmer is supplied with a built-in default
programme that can be stored/used for conven-
ience.
To store the default programme, simply press and
hold both the + and - buttons for 3-seconds.

Day 1

HTG

HW

ON1

6:30

6:30

OFF1

8:30

8:30

ON2

16:30

16:30

OFF2

22:30

22:30

Day 2

HTG

HW

ON1

6:30

6:30

OFF1

8:30

8:30

ON2

16:30

16:30

OFF2

22:30

22:30

Day 3

HTG

HW

ON1

6:30

6:30

OFF1

8:30

8:30

ON2

16:30

16:30

OFF2

22:30

22:30

Day 4

HTG

HW

ON1

6:30

6:30

OFF1

8:30

8:30

ON2

16:30

16:30

OFF2

22:30

22:30

Day 5

HTG

HW

ON1

6:30

6:30

OFF1

8:30

8:30

ON2

16:30

16:30

OFF2

22:30

22:30

Day 6

HTG

HW

ON1

6:30

6:30

OFF1

9:00

9:00

ON2

16:00

16:00

OFF2

22:30

22:30

Day 7

HTG

HW

ON1

6:30

6:30

OFF1

9:00

9:00

ON2

16:00

16:00

OFF2

22:30

22:30

DEFAULT PROGRAMME

5.2.4

PROGRAMMING PROCEDURE
For each channel (C1 & C2) there are 2 timed ON
settings, and 2 timed OFF settings for each day of
the week. The programming sequence for each
channel is as follows:

programme the C1 channel (heating) 1

st

 ON then

1

st

 OFF, then 2

nd

 ON and then 2

nd

 OFF for each

day of the week starting from day 1 (Monday).
The same procedure will be carried out for the
remaining subsequent days (day 2 till day 7)

after the final OFF (2

nd

 OFF, day-7) setting has

been programmed on C1, the display will move
to show the programming icons on channel C2
(hot water).  C2 can then be programmed in the
same sequence as detailed for C1.

To adjust or re-programme the default programme,
please proceed as follows:

Press and hold the 

P button for 3-seconds, the

display will show 

PRO for 1-second to signal that

the programmer is now ready to be re-pro-
grammed/adjusted (programming mode).

The first day of the week will blink on the display,
followed by the HTG ‘ON’ icon, then followed by
the stored value (time).

To adjust the current – stored – value, press
either the + or - button to increase or decrease
the displayed value to the desired setting.

Press 

P to confirm and store the new value.

Use the same (above) sequence for the subse-
quent ON/OFF settings and subsequent days.

Once the programming of C1 (heating) channel
has been completed, the programmer sequence
will automatically move on to C2 (hot water).

NOTE
If no buttons are pressed within a 10-second pe-
riod, the programmer will exit the programming
mode and revert to the normal display.
To review the current stored programmes, press
and release the 

P button whereby the display will

scroll through the current stored programmes. To
exit and return to the current operating mode, press
and release the 

P button.

5.2.5

OPERATING MODES
Each channel (C1 & C2) has 3-different modes of
operation:

Automatic: using the stored ON/OFF settings

ON: 24-hours each day

OFF: 24-hours each day.

To change the operating mode, press either C1 or
C2 (depending on your preference) and select the
desired mode of operation.

Manual operation - OFF

1 2 3 4 5 6 7

MAN

AUTO

MAN
AUTO

12:34

OFF

ON

OFF
ON

Manual operation - ON

1 2 3 4 5 6 7

MAN

AUTO

MAN
AUTO

12:34

OFF

ON

OFF
ON

Automatic (programmed settings)

1 2 3 4 5 6 7

MAN

AUTO

MAN
AUTO

17:34

OFF

ON

OFF
ON

1 2 3 4 5 6 7

MAN

AUTO

MAN
AUTO

15:22

OFF

ON

OFF
ON

Содержание Mynute HE

Страница 1: ...INSTRUCTIONS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK M...

Страница 2: ...erson responsible for the property in which the appliance is located installed A replacement copy can be obtained from Vokera customer services Contents Introduction Page Dear customer 2 Do s and don...

Страница 3: ...ated water to your radiators and hot water tank The central heating and hot water is controlled via a time clock or programmer and any thermo stats that your installer may have fitted The boiler will...

Страница 4: ...temperature of the boiler however in certain circumstances a fault code or specific characters will be displayed to indicate that the appliance is performing a specific func tion 1 Pressuregauge 2 Mo...

Страница 5: ...ndardCH systems and between 20 C 45 C under floor CH systems The 2 digit LED display normally shows the operatingtemperatureoftheappliance howeverit can also display additional characters or flashing...

Страница 6: ...re occurs AL21 Reset appliance Call engineer if fault re occurs AL26 Reset appliance Call engineer if fault re occurs AL28 Reset appliance Call engineer if fault re occurs AL34 Reset appliance Call e...

Страница 7: ...he Vokera mechanical clock it can be used and adjusted as follows Setting the time The time of day can be set by grasping the outer edge of the black dial and turning it in a clockwise direction until...

Страница 8: ...for C1 Toadjustorre programmethedefaultprogramme please proceed as follows Press and hold the P button for 3 seconds the displaywillshowPROfor1 secondtosignalthat the programmer is now ready to be re...

Страница 9: ...Supplied By www heating spares co Tel 0161 620 6677 9...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 12: ...ries vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 099 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve t...

Отзывы: