HOW TO...

3.1

HOW TO TOP-UP THE SYSTEM PRESSURE
(fig. 3 & 4)
The system pressure must be checked periodi-
cally to ensure the correct operation of the boiler.
The needle on the gauge should be reading be-
tween 1 and 1.5 BAR when the boiler is in an off
position and has cooled to room temperature. If
the pressure requires ‘topping-up’ use the follow-
ing instructions as a guide.

Locate the filling valve connections (usually
beneath the boiler, see fig. 3).

Attach the filling loop to both connections.

Open the filling valve slowly until you hear water
entering the system.

Close the filling valve when the pressure gauge
(on the boiler) reads between 1 and 1.5 BAR.

Remove the filling loop from the connections.

3.2

HOW TO RESET THE APPLIANCE
When the red fault LED is illuminated, the appli-
ance will require to be reset manually. Before
resetting the boiler, check what action is required
to be taken, using the information on the fault code
table below. Allow a period of two minutes to
elapse before rotate the status mode knob. To
reset the alarm the status mode knob has to cross
the OFF position.

Fig. 4

flow/return

pipe

control

valve

temporary

connection

control

valve

supply

pipe

double

check valve

Fig. 3

CODE

ACTION REQUIRED

AL10

Reset appliance. Call engineer if fault re-occurs

AL20

Reset appliance. Call engineer if fault re-occurs

AL21

Reset appliance. Call engineer if fault re-occurs

AL26

Reset appliance. Call engineer if fault re-occurs

AL28

Reset appliance. Call engineer if fault re-occurs

AL34

Reset appliance. Call engineer if fault re-occurs

AL40

Check system pressure and refill if necessary.
Reset appliance. Call engineer if fault re-occurs

AL41

Check system pressure and refill if necessary.
Call engineer if fault re-occurs

AL52

Call engineer

AL55

Call engineer

AL60

Call engineer

AL71

Call engineer if fault re-occurs

AL73

Call engineer if fault re-occurs

AL74

Reset appliance. Call engineer if fault re-occurs

AL79

Reset appliance. Call engineer if fault re-occurs

APPLIANCE FAULT CODES

IMPORTANT
If the appliance requires to be reset frequently, it
may be indicative of a fault, please contact your
installer or Vokera Customer Services for further
advice.

3.3

HOW TO SHUT DOWN THE SYSTEM FOR
SHORT PERIODS
The system and boiler can be shut down for short
periods by simply turning the time clock to the off
position. It is also advisable to turn off the main
water supply to the house.

3.4

HOW TO SHUT DOWN THE SYSTEM FOR LONG
PERIODS
If the house is to be left unoccupied for any length
of time – especially during the winter – the system
should be thoroughly drained of all water. The gas,
water, and electricity supply to the house should
also be turned off. For more detailed advice
contact your installer.

3.5

HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp
cloth. Do not use any scourers or abrasive
cleaners.

 correct

pressure

value

Содержание Mynute HE

Страница 1: ...INSTRUCTIONS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK M...

Страница 2: ...erson responsible for the property in which the appliance is located installed A replacement copy can be obtained from Vokera customer services Contents Introduction Page Dear customer 2 Do s and don...

Страница 3: ...ated water to your radiators and hot water tank The central heating and hot water is controlled via a time clock or programmer and any thermo stats that your installer may have fitted The boiler will...

Страница 4: ...temperature of the boiler however in certain circumstances a fault code or specific characters will be displayed to indicate that the appliance is performing a specific func tion 1 Pressuregauge 2 Mo...

Страница 5: ...ndardCH systems and between 20 C 45 C under floor CH systems The 2 digit LED display normally shows the operatingtemperatureoftheappliance howeverit can also display additional characters or flashing...

Страница 6: ...re occurs AL21 Reset appliance Call engineer if fault re occurs AL26 Reset appliance Call engineer if fault re occurs AL28 Reset appliance Call engineer if fault re occurs AL34 Reset appliance Call e...

Страница 7: ...he Vokera mechanical clock it can be used and adjusted as follows Setting the time The time of day can be set by grasping the outer edge of the black dial and turning it in a clockwise direction until...

Страница 8: ...for C1 Toadjustorre programmethedefaultprogramme please proceed as follows Press and hold the P button for 3 seconds the displaywillshowPROfor1 secondtosignalthat the programmer is now ready to be re...

Страница 9: ...Supplied By www heating spares co Tel 0161 620 6677 9...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 12: ...ries vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 099 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve t...

Отзывы: