CONDEXA PRO
36
The
Vokera CONDEXA PRO
Boiler is not fitted with an
automatic filling valve, which must be installed on the
system return.
FILLING
- Open the valves (1) installed on the boiler water fittings;
- Open the caps on the automatic vent valve/valves (2)
two or three turns;
- Open the filling valve on the system until the pressure
shown on the pressure gauge is
1,5 bar
;
- Close the filling valve again.
b
The air is vented from the
CONDEXA PRO
boiler
automatically through the automatic vent valve/val-
ves installed on the top of the heating units.
Check that the cap on the valve is open.
MI
RI
GAS
1
2
2
FILLING AND EMPTYING THE SYSTEMS