5
Fan PWM signal (%).
If PWM = 100%, this corresponds to 99 on the display.
E.g.: 66 %
6
Flow switch contact open/closed (not active)
E.g.: contact open
7
Pump or motorised valve on the individual unit on/off
E.g.: Pump ON
E.g.: Pump OFF
8
Maximum ionisation current (range from 0 to 99) at first attempt
E.g.: maximum ionisation current 80
INSTALLER PROGRAMMING MODE
The installer parameters can be changed by entering the password (
22
).
The password for the installer level allows access to display and change the user and installer parameters.
Procedure to enter programming mode:
Procedure
Display
1
E.g.: the outlet temperature T1 is 80°C
2
Press “
MODE
” and “
MEMO
”. After 5 seconds the second and third digit will flash.
3
Use “
+
” and “
-
” to enter the first number in the password on the centre digit.
E.g.: password = X2
4
Press “
MEMO
” to save the second number in the password.
5
Use “
+
” and “
-
” to enter the first number in the password on the centre digit.
E.g.: password = 22
5
Press “
MEMO
” to confirm the password, if the password is wrong
the board returns to Display mode.
6
Press “
+
” and “
-
” to scroll the parameters enabled by the password.
Press “
MODE
” to start setting the parameters.
The code P-XX and the corresponding value will alternate on the display.
7
Use “
+
” and “
-
” to change the value of the parameter.
Whenever a button is pressed, the alternating display of the parameter
and the corresponding value is stopped for 5 seconds and only the value is shown.
8
Press “
MEMO
” to save the new value of the parameter.
To exit installer programming mode press “
MEMO
”.
For the complete list of parameters see page 58.