05TA Service Manual
OPTIONS AND ACCESSORIES
8/13/01
10-15
Phase Unbalance
Use the arrow keys to set the Phase Unbalance percentage (2 to 20%) of incoming 3 Phases. This
will turn off equipment for a specified time if incoming Phase Unbalance exceeds set percentage. The
Default is 5% which is the recommended value for normal operation.
Delay On Fault
Ranges from Off to 15 seconds in .1 second increments. Use the arrow keys for adjustment. “Delay
On Fault” is energized when any line fault occurs. The fault must be present set time in order to be
registered or acted upon. Default is 2.0 seconds.
Contactor Test
Selectable number of Contactor Retries (1 to 10 or OFF) on Contactor Fault. Use the arrow keys to
adjust the number of times the contactor will be operated in order to seal the contacts. Setting retries
to OFF means do not check load side. Any input to the load inputs will be ignored. Default is off.
Reset Mode
(Manual/Automatic) Choose whether to let the unit automatically reset or to wait for you to manually
reset it. The recommended setting is automatic because faults must be cleared in order to reset from
the manual mode. To reset from a fault condition in the manual mode press and hold the fault button
for two seconds. Default is manual reset.
Control Mode
This setting allows you to select the control source. Pressing the arrow keys in this setup mode takes
you through ON, OFF and EXTERNAL. The normal setting would be EXTERNAL. With the
control set to EXTERNAL, the unit will respond to the signal connected to the CONTROL input.
With the control mode set to ON, the unit will turn on its output relay if line parameters are within
setup parameters. Setting the control mode to OFF causes the unit to ignore the control input and
keep its output relay off. Default is external.
Read Mode
For reading individual phase to phase voltages, pressing the read key will enter read mode. Press the
read key to step through the voltages. Read voltages in the following order.
Voltage A to B. -- Voltage A to C. -- Voltage B to C.
Pressing the read key again will exit read mode.
Fault Mode
Recalls faults (from most recent to the oldest in order). Press the FAULT key to enter fault mode.
FAULT #1 is the most recent fault. Press the fault key again to step to the next fault. Pressing the
fault key at the last fault will exit fault mode. Press and hold fault key down for two seconds to clear
fault from memory and reset the unit.
Содержание TUBE-ICE 05TA
Страница 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Страница 46: ...05TA Service Manual ELECTRICAL CONTROLS 8 13 01 6 4 FIGURE 6 2 Electrical Schematic All Voltages 50 60 Hz ...
Страница 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Страница 83: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 19 FIGURE 9 11 Cutter Parts crushed ice option ...
Страница 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Страница 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Страница 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...
Страница 111: ...05TA Service Manual INDEX 8 13 01 12 4 ...