05TA Service Manual
OPTIONS AND ACCESSORIES
8/13/01
10-7
MACHINE FAULTS
Hi/Low Pressure
. The interface will display the message shown below if the combination high/low
pressure safety switch opens. The machine will stop immediately.
B=SILENCE ALARM
“A” FOR RESTART
FAULT:HI/LOW
RESET
When the low pressure switch resets or the manual reset button for the high pressure safety is
depressed and the pressure is in the acceptable range, the interface will display “PRES OK”.
B=SILENCE ALARM
“A” FOR RESTART
FAULT:HI/LOW
PRES OK
After the safety switch is reset it will be necessary to press the “A” button on the operator interface to
return to the start up screen. Pressing “B” on the operator interface at this time will open the alarm
contacts. Button “C” will always change the display to the set-up screen when a fault screen is
displayed.
Cutter or Pump Overload.
The interface will display the message shown below if the water pump
overload protection trips open. The machine will stop immediately, and the overload reset button
located on the motor starter must be depressed.
B=SILENCE ALARM
“A” FOR RESTART
FAULT:PUMP O/L
PUMP OL: RESET
B=SILENCE ALARM
“A” FOR RESTART
FAULT:PUMP O/L
PUMP OL: OK
When the overload has been reset the interface will display “PUMP OL: OK”. It will be necessary to
press “A” on the operator interface to restart the machine. The cutter overload fault display operates
identically to the pump overload displays.
Low Oil Pressure:
The interface will display the message shown below if the compressor oil pressure
safety switch opens. The machine will stop immediately, and the oil pressure switch must be reset
manually, by depressing the red button located on the front of the oil pressure safety switch.
B=SILENCE ALARM
“A” FOR RESTART
FAULT:OIL PRESS
OIL: RESET
B=SILENCE ALARM
“A” FOR RESTART
FAULT:OIL PRESS
OIL: PRES OK
When the oil pressure safety switch has been reset the interface will display “OIL: PRES OK”. It will
be necessary to press “A” on the operator interface to restart the machine.
PLC (Programmable Logic Controller)
Содержание TUBE-ICE 05TA
Страница 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Страница 46: ...05TA Service Manual ELECTRICAL CONTROLS 8 13 01 6 4 FIGURE 6 2 Electrical Schematic All Voltages 50 60 Hz ...
Страница 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Страница 83: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 19 FIGURE 9 11 Cutter Parts crushed ice option ...
Страница 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Страница 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Страница 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...
Страница 111: ...05TA Service Manual INDEX 8 13 01 12 4 ...