31
Useful Tips
Useful
Tips
for trouble-free operation
15
.1
Flow Rate is Insufficient
15
.2
Discharge Pressure is Insufficient
9.- Pump sealing defective.
Possible Causes
Solutions
· Check and complete the filling of the system with
liquid.
· Check the delivery geometric height.
· Check pressure losses in the delivery pipe
(partially closed valve, foreign bodies, back
pressure too low).
2.- The discharge head is too high (higher than that
for which the pump was selected).
1.- The pump is not primed.
3.- The suction lift is too high (insufficient
NPSH).
· Check that NPSHavailable > NPSHrequired
· Check suction geometric head.
· Check for head losses in the suction line (partially
closed valve, foreign bodies, back pressure too
low).
4.- The impeller ducts are partially clogged.
5.- Discharge head other than specified.
· Check and release blockage.
· Re-calculate manometric height of the new system.
6.- Air enters the suction pipe.
· Check and repair damaged ducts and
defective joints.
7.- Damaged internal mechanical pump adjustments.
· Consider a pump repair.
8.- The foot valve or pipe is not sufficiently
submerged.
· Check and submerge as necessary.
· Check and replace all pump sealing parts such as
O'rings, mechanical seals or gaskets.
3.- Damaged internal mechanical pump adjustments.
Possible Causes
Solutions
2- Air enters the suction pipe.
· Check and repair damaged ducts and
defective joints.
· Consider a pump repair.
4- The viscosity of the liquid is higher than initially
expected.
· Check and consult the
manufacturer.
1- Flow rate different from that specified.
· Re-calculate system flow requirements.
Содержание 100/75 HAD