2
7
Uncoupling
Necklace
IF THE CLAMPING PARTS OF THE DECOUPLING COLLAR ARE NOT CORRECTLY ADJUSTED, THE IMPELLER WILL NOT FIT
TIGHTLY AND MAY COME LOOSE DURING ROTATION.
REMOVING THE DECOUPLING COLLAR
To remove the system, the extractor bolts are tightened to apply pressure against the shaft and release the wedges.
!
WARNING
Pump Liner
Assembly
Instructions
Table 10 below lists the recommended torque values for CASING THREADS. These values should be followed on all pumps, but
are extremely important on metal lined pumps.
Table 10. Torque table
Pump Liner
Assembly
Instructions
Uncoupling
Necklace
1
2
.1
Decoupling Necklace Installation
The uncoupling collar allows the impeller to be released, this design does not require complete disassembly and is vital for
complete Wet End replacement.
The system consists of shims, shim set screws, housing and extractor bolts.