24
NOTE: Due to their size, 400/350 2122 HAD pumps only allow discharge orientations "C" and "G".
1.Lift press housing in the correct position and rotate to position it in the required position. Refer to Figure 14. Place nuts
and tighten to torque value in Table 9. For rubber lined pumps only, insert COVER PLATE BOLTS into frame plate bosses,
place nuts and tighten securely.
Figure 14. Placement of the casing on the press side
Table 9: Stud bolt torque table Housing
Assembly Instructions
the
Bearing Holder Base
9.
2
Placement of Press Side Housing and Fastening Bolts
Assembly Instructions
the Bearing Holder
Base
Содержание 100/75 HAD