Pump
Maintenance
FRAME SIZE
BEARING HOLDER
ADD
[gr]
RPM OF THE BEARING HOLDER
200
300
400
600
800
1000
1200
1500
2000
2500
3000
4000
2
6
3000
2400
1800
1500
1000
800
650
300
3
9
3600
2400
1800
1600
1200
900
580
500
*
4
14
2500
2000
1500
1200
800
500
500
6
35
7000
4200
2000
1800
1200
700
400
400
19
50
3000
2000
1400
1000
600
400
400
2021
66
3800
2800
1500
900
500
300
2122
125
4800
3000
1800
900
400
400
19
33
3000
2000
1400
1000
600
400
2021
50
3800
2800
1500
900
500
300
2122
42
4800
3000
1800
900
400
400
Suggested lubrication interval (hours) based on Mobil XHP 222 standard mineral grease
Table 3: Recommended grease used
Pump
Maintenance
6.1
Impeller Adjustment
As mentioned above, pump efficiency and component wear rate vary as a function of the GAP between the impeller and
the pump. Accordingly, the pump should have a GAP between 1 and 2 [mm] to achieve the best performance. For a
pump with centrifugal seal it is recommended to double this difference, so as not to increase the seal area pressure.
6.2
Bearing Lubrication
For reliable operation it is recommended to regularly inspect the bearing temperature and determine the frequency, the
amount of lubricant to be added and the date of the next inspection. These depend on the size of the bearing holder, the
operating speeds and mainly on the judgment of the field maintenance team according to the measured bearing
temperatures.
6.3
Grease Lubricants
Grease with the following technical specifications is recommended: