13
Pumps running under normal operation conditions should
be inspected at least once a year. If the pumped liquid is
very muddy or sandy or if the pump is operating continu-
ously, the pump should be inspected every 1.000 operat-
ing hours.
For long and trouble-free operation of the pump, following
points should be checked regularly:
- Nominal current (A): Check with amp-meter.
- Pump parts and impeller: Check for possible wear.
Replace defective parts.
- Ball bearings: Check the shaft for noisy or heavy
operation (turn the shaft by hand). Replace defective ball
bearings. A general overhaul of the pump is usally
required in case of defective ball bearings or poor motor
function. This work must be carried out by an authorized
service workshop.
- Cable entry: Make sure that the cable entry is watertight
and that the cables are not bent sharply and/or pinched.
Additionally at pump types with oil chamber:
- Oil level and oil condition in oil chamber:
Put the pump in horizontal position, so that the screw of
the oil chamber is above (at larger pumps: one of both
screws). Remove the screw and infer a small quantity of
oil. The oil becomes greyish white like milk if it contains
water. This may be the result of defective shaft seal.
In this case leave the condition of the shaft seals by a
VOGEL Service to examine.
The oil should be replaced after 3000 operating hours.
Oil type: Shell Tellus C22. Used oil is to be disposed
accordingly.
For long and trouble-free operation of the unit we
recommend the following measures:
•
Clean the pump station with clear water and
scour the pump station by running pumps every
6 months.
•
Check the operatability and the mobility of the
niveau sensors every 6 months.
•
Make an arrangement with you VOGEL agent for
an annual maintenance.
Servicing Contract
For a regular expert execution of all necessary
maintenance and inspection we recommend the
conclusion of a servicing contract by our VOGEL Service.
Pump type
No.
Correspond to our warranty conditions
we achieve
12 months of warranty
10. Warranty receipt
Содержание SEKAMATIK 200 E UF