2.5 Setting Up the Carbonator Unit (Where Fitted)
1. Open the cabinet door. Fit the seal (1), provided in the
installation kit, to the regulator as shown in the
photograph. Connect the regulator to the gas bottle.
2. Tighten the locknut. Carefully lift the cylinder into the
machine ensuring that the gas supply pipe is not
trapped or obstructed in any way.
Safety First!
The cylinder may be heavy. Always follow
the correct procedure when lifting heavy objects.
3. Secure the gas bottle with the safety chain. Turn on the
gas supply from the bottle and ensure that the
regulator (2) is indicating a gas pressure of 35 PSI.
4. Place the carbonator overflow pipe into the waste
bucket. Fill the carbonator water bath with clean cold
water until it starts to flow from the overflow pipe.
5. Switch on the carbonator unit using the Cold Unit
switch located near the power supply.
6. Place the syrup containers in the bottom right-hand side of the cabinet and insert the
dip tubes into the containers ensuring that the correct flavours correspond to the
drinks displayed on the selection decals.
7. Prime the syrup selections ready for use by
pressing button 13 on the service keypad. The
LCD will display the screen opposite.
N.B.
Ensure that the waste bucket is empty and
in place before priming the pumps.
8. To prime syrup pump 1, press and hold button 1 on the drink selection keypad until
the syrup appears from the dispense head. Repeat for syrup pump 2 by pressing and
holding button 2 on the drink selection keypad. Press the X (Exit) key to return the
machine to standby mode. Empty the waste bucket and refit to the machine.
9. Test vend the carbonated drinks to ensure correct operation of carbonator unit.
Check for leaks and ensure that the machine is left in a clean and safe condition.
Close the door.
N.B.
If a still unit is fitted ensure that the ingredient timers for syrup drink 1 and 2 are
set to 6 seconds (recommended).
1