background image

 

 

 

1.

 

Parts: 

 
 

1. 

BYPASS 

8. 

BLENDING REGULATOR 

2. 

VALVE HOUSING 

9. 

HARDNESS REGULATOR 

3. 

RESIN TANK 

10. 

TO BRINE VALVE 

4. 

CONTAINER FOR DEVICE AND SALT 

11. 

CONNECTIONS (1/2",3/4”, 1") 

5. 

BRINE VALVE (float) 

12. 

TO DRAIN 

6. 

WATER 

INLET

 

13. 

COMMUNICATION TUBES 

7. 

WATER

 OUTLET

 

14. 

TUBES TO BRINE VALVE 

Содержание duomatik evoline

Страница 1: ...tener the installation guide has to be read carefully For any disturbances cause by disregarding the instructions evo water doesn t accept liability evo water oHG Falkenstra e 2 72589 Westerheim Tel 4...

Страница 2: ...e protection of the central tax valves from rust sand etc a suitable mudflap or fine filter should be inserted before the arrangement The filter pad of the fine filters should be exchanged according t...

Страница 3: ...OR 2 VALVE HOUSING 9 HARDNESS REGULATOR 3 RESIN TANK 10 TO BRINE VALVE 4 CONTAINER FOR DEVICE AND SALT 11 CONNECTIONS 1 2 3 4 1 5 BRINE VALVE float 12 TO DRAIN 6 WATER INLET 13 COMMUNICATION TUBES 7 W...

Страница 4: ...and drain 12 against frost Make sure you have the latest installation manual at hand Check with your evo water supplier 3 Installation 3 1 Close main valve and make sure pressure is released from pip...

Страница 5: ...ue dot 3 4 C u t o p e n m a i n w a t e r supply in order to install direct connections to the evo water Softener or to install the evo water Bypass recommended Follow the arrows on both Bypass and s...

Страница 6: ...rain pipe is spirally reinforced to avoid later blocking and or kinks It is possible that both drains are connected with each other through a Y piece In this case connect the Y piece to the local drai...

Страница 7: ...been drilled mount the overflow tap and secure it with the supplied nut After drilling remove all bits of plastic that have fallen into the container A separate instruction leaflet with detailed info...

Страница 8: ...e no kinks in the tube and that the tube is not squeezed together Pay attention Watch carefully that you don t squeeze the tube when opening or closing the tilt drawer for the salt 4 Settings 4 1 Hard...

Страница 9: ...setting 5 Start up 5 1 Leave Bypass in bypass mode open main valve and flush for several minutes in order to avoid impurities from entering the softener When you do not use a Bypass open the main val...

Страница 10: ...ner This will happen only once at start up Once only water flows from the tap and no more air close the tap 5 6 Perform a manual regeneration 5 6 1 Choose one of both units to perform a manual regener...

Страница 11: ...rm until it stops automatically The estimated time is approx 12 minutes When regeneration has stopped no more water flows to the drain This is a clear indication that the regeneration stage is over 5...

Страница 12: ...fixed in the open position In this position you can easily refill the drawer with salt tablets When you are done refilling the salt just lift the cover a little bit and push the tilt drawer back in t...

Страница 13: ...knowledge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Softener will guarantee optimal functioning...

Отзывы: