2.
Precautions:
Make sure you have all necessary tools on hand before you begin with the
installation.
Follow all local legal regulations.
Read this manual carefully
. If you have any questions or remarks, please
contact your evo-water supplier.
Check incoming pressure: minimum 1 bar (dynamic), maximum 8 bar (static)
(15 PSI – 116 PSI). If necessary reduce incoming pressure.
Do not install the evo-water softener close to a heating source (environment
temperature must be below 40°C).
Protect softener and drain (12) against frost.
Make sure you have the latest installation manual at hand. Check with your
evo-water supplier.
3.
Installation:
3.1
Close main valve and make sure pressure is released from piping. This can be
done by opening at least one tap.
3.2
Connect the two units by means of the provided Y-pieces. You can find them in
the salt compartment. The Y-piece with the filter inside, needs to be mounted
at the inlet of the valve. (= bottom connection) The other must be mounted at
the other connection.
First connect the Y-piece to one unit and afterwards to the other unit. Secure
them with the provided clips (4 pieces). You don’t need to take the units out of
the container to do this.