Safety instructions: 

 

1.  Before installation the softener: 

Please  refer  to  the  corresponding  installation 

–  and  operation 

instructions in this manual. 

 

2.  Please  refer  to  the  local  installation  regulations  and  the  general 

directives, in particular DIN 1988 and EN1717, also the valid accident 
prevention regulations. 

 
3.  With not designated use and improper service the manufacturer is 

released from any liability. 

 
4.  Before the installation please check the statics of the walls, covers and 

grounds for loading capacity. 

According to place of action a backflow must be installed 
corresponding to local regulation before the arrangement. 
For the protection of the central tax valves from rust, sand etc. a 
suitable mudflap or fine filter should be inserted before the 
arrangement. The filter pad of the fine filters should be exchanged 
according to DINAR / DVGW at a distance of 6 months or after soiling. 
Please ensure that no water damages are caused (e.g., by ground 
expiry). The manufacturer is not liable for water damages. 
The food water of the arrangement must correspond to the information 
of the German drinking water order.  
The room temperature must be at least 7°C and may not cross 50°C. 
 

5.  Changes in the system may not be made without consultation and 

approval with evo-water oHG, for damages no other guarantee is 
taken over. 

 
6.  The system serves exclusively for the removing of undesirable mineral 

substances which retreat as a scale. It serves as a pure system 
protection. 

Содержание duomatik evoline

Страница 1: ...tener the installation guide has to be read carefully For any disturbances cause by disregarding the instructions evo water doesn t accept liability evo water oHG Falkenstra e 2 72589 Westerheim Tel 4...

Страница 2: ...e protection of the central tax valves from rust sand etc a suitable mudflap or fine filter should be inserted before the arrangement The filter pad of the fine filters should be exchanged according t...

Страница 3: ...OR 2 VALVE HOUSING 9 HARDNESS REGULATOR 3 RESIN TANK 10 TO BRINE VALVE 4 CONTAINER FOR DEVICE AND SALT 11 CONNECTIONS 1 2 3 4 1 5 BRINE VALVE float 12 TO DRAIN 6 WATER INLET 13 COMMUNICATION TUBES 7 W...

Страница 4: ...and drain 12 against frost Make sure you have the latest installation manual at hand Check with your evo water supplier 3 Installation 3 1 Close main valve and make sure pressure is released from pip...

Страница 5: ...ue dot 3 4 C u t o p e n m a i n w a t e r supply in order to install direct connections to the evo water Softener or to install the evo water Bypass recommended Follow the arrows on both Bypass and s...

Страница 6: ...rain pipe is spirally reinforced to avoid later blocking and or kinks It is possible that both drains are connected with each other through a Y piece In this case connect the Y piece to the local drai...

Страница 7: ...been drilled mount the overflow tap and secure it with the supplied nut After drilling remove all bits of plastic that have fallen into the container A separate instruction leaflet with detailed info...

Страница 8: ...e no kinks in the tube and that the tube is not squeezed together Pay attention Watch carefully that you don t squeeze the tube when opening or closing the tilt drawer for the salt 4 Settings 4 1 Hard...

Страница 9: ...setting 5 Start up 5 1 Leave Bypass in bypass mode open main valve and flush for several minutes in order to avoid impurities from entering the softener When you do not use a Bypass open the main val...

Страница 10: ...ner This will happen only once at start up Once only water flows from the tap and no more air close the tap 5 6 Perform a manual regeneration 5 6 1 Choose one of both units to perform a manual regener...

Страница 11: ...rm until it stops automatically The estimated time is approx 12 minutes When regeneration has stopped no more water flows to the drain This is a clear indication that the regeneration stage is over 5...

Страница 12: ...fixed in the open position In this position you can easily refill the drawer with salt tablets When you are done refilling the salt just lift the cover a little bit and push the tilt drawer back in t...

Страница 13: ...knowledge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Softener will guarantee optimal functioning...

Отзывы: