background image

 1 

FILTRATION & PROCESSING SOLUTIONS

COLDRINK SERIES INSTALLATION AND OPERATION GUIDE

SELECT A MOUNTING LOCATION

Figure 1 Coldrink 1 System

Figure 2 Coldrink 2 System

Figure 3 Coldrink 3 System

EVERPURE

®

 

COLDRINK

®

 SERIES FILTER SYSTEMS

2.  The location should allow for:

•  Minimum clearance of 2-1/2” (6.4 cm) under the 

cartridge(s) so it can be lowered for removal  

and replacement.

•  Adequate space for “in” and “out” water  

line connections.

•  Be near a drain for flushing and near a 110V outlet 

if the accessory (sold separately) Everguard

TM

 Low 

Pressure Alarm is used. See Figures 1-6.

1.   Give consideration to the weight of the unit when 

operating (filled with water). Operating weights of the 

Coldrink Systems are:

•  System 1 - 19 lbs (8.62 kg)
•  System 2 - 35 lbs (15.9 kg)
•  System 3 - 45 lbs (20.4 kg)

INSTALLATION

1.   Use the predrilled mounting holes in the manifold 

bracket as guides. Mark and drill anchor holes. Mount 

securely. See Figures 4-6. 

2.  Shut off power to equipment.
3.  Connect outlet port of Coldrink System to equipment 

served. Always use a NSF approved pipe dope or 

plumber tape at all connections. Use a backup wrench 

on all fittings while connecting to avoid excessive stress 

on the system components.

4.  Install a manual shut-off valve leading to the system  

for servicing.

5.  Connect minimum 3/8” water line to the Coldrink 1 

System inlet.  Use a minimum 1/2” for Coldrink 2  

and 3 Systems.

6.  Connect tubing to flushing valve and run to drain. The 

cross fitting has a flushing valve installed on the bottom.

NOTE:  Some municipal plumbing codes and good 

sanitary practices require an air gap at the drain 

termination point.

7.  Shut off the system inlet valve located on the inlet of the 

prefilter head.

8.  Check to be sure the o-ring on the prefilter housing is 

sufficiently lubricated. Use a good grade of silicone  

lubricant, if needed. Position the EC210 Prefilter 

Cartridge on guide seat in the bottom of the bowl. Then 

thread the bowl into the head by hand. Use a sump 

wrench to snug the bowl onto the head.

9.   Install the carbon filter cartridge(s) into the filter head(s) 

following directions on the cartridge label or as shown in 

the Cartridge Change Change Procedure  

section illustrations.

10. Turn on inlet water to the filter system and check  

for leaks.

Summary of Contents for Coldrink series

Page 1: ...use a NSF approved pipe dope or plumber tape at all connections Use a backup wrench on all fittings while connecting to avoid excessive stress on the system components 4 Install a manual shut off valve leading to the system for servicing 5 Connect minimum 3 8 water line to the Coldrink 1 System inlet Use a minimum 1 2 for Coldrink 2 and 3 Systems 6 Connect tubing to flushing valve and run to drain...

Page 2: ...ET 3 4 FNPT Figure 6 Coldrink 3 Outlet 3 4 FNPT INLET 3 4 FNPT 25 75 29 59 FLUSHING For maximum life all carbon filter cartridges must be flushed for five 5 minutes at full flow before use ALL NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE If the cartridges are new have been properly flushed and both needle and follower register inadequate pressure or the ...

Page 3: ...et water ahead of system 2 Push red relief valve Unscrew bowl Remove prefilter cartridge 3 Clean bowl with filtered water only NO SPECIAL CLEANERS 4 Feel head o ring If dry lubricate with high quality silicone lubricant 5 Install new prefilter cartridge in bowl Hand tighten bowl onto head 6 Turn on water Turn on power to equipment Everpure Carbon Filter Cartridge Change 1 Shut off power to equipme...

Page 4: ...TEL 81 0 42 775 3015 FAX INFO EVERPURE CO JP EMAIL EVERPURE SHURFLO SOUTHEAST ASIA 390 HAVELOCK ROAD 04 01 KING S CENTRE SINGAPORE 169662 65 6795 2213 TEL FAX 65 6795 2219 FAX CSEVERPURE PENTAIR COM EMAIL OPERATING SPECIFICATIONS COMBINED MODEL NAME REPLACEMENT CARTRIDGE FLOW RATE CAPACITY GPM LPM GALLONS LITRES Coldrink System 1 MC MC 1 67 6 3 9 000 34 000 Coldrink System 1 MC2 MC2 1 67 6 3 12 00...

Reviews: