![VNS UD101 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/vns/ud101/ud101_user-manual_1043368037.webp)
UD101L User Guide Document: UD101L-2
----------------------------------------------------------------------------------------------------------------------------- ---------------
36
✓
Input / Output resolution and Profile Index settings will remain the same without reset.
➢
[Warp Adjust]
✓
[P]: Enable grid pattern with different colors (R, G, B, C, M, W) & styles
✓
[CTRL + P]: Disable grid pattern
✓
Start from [2x2] alignment, then follow [3x3]
→
[5x3]
→
[9x5]
→
[17x17] sequence for
geometry alignment. If go back to lower control point adjustment, it will reset higher control
point adjustment. [2x2] alignment will not reset curve adjustment result.
✓
[M]: Change Adjust mode from [2x2]
→
[3x3]
→
[5x3]
→
[9x5]
→
[17x17]
(PC language shall set to English, otherwise, some hotkey functions may not work)
✓
Use [CTRL + Arrow] key to select control point.
✓
Use [Arrow] key to adjust control point position with default step (8 pixels/step)
✓
Use [Shift + Arrow] key to adjust control point position with 1 pixel/step.
➢
Save settings
✓
Click # key under [Save to Box] to save the setting to Box. one
✓
After finishing all channel geometry alignment and [Save to Box], click [System] to save all
channel settings into [Profile Save].
✓
Click [Save Setting] to save data into PC as backup or copy to another Box.
8.2.4. Gwarp3 Image Position [Finetune] via remote controller
➢
While executing geometry alignment by Gwarp3, user still can execute geometry alignment
through remote controller at the same time. The maximum grid pattern for remote controller is
only up to 9x5. All the grid above 9x5 will be reset and only up to 9x5 grid will be kept.
➢
If the system is installed based on Gwarp3 geometry data (up to 17x17 grids) which is saved in
UserMap, user still can execute small position modification through [Finetune] under [GWarp]
menu via remote controller. User can only execute 2x2 fine-tune with a range of +-50 pixels for
each corner.
➢
This function is important for after service and while changing lamp to return the image to