![VNS UD101 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/vns/ud101/ud101_user-manual_1043368027.webp)
UD101L User Guide Document: UD101L-2
----------------------------------------------------------------------------------------------------------------------------- ---------------
26
➢
Geometry alignment range from remote controller can be up to 600 pixels in [2x2] + 600
pixels more in [3x3] for one corner/edge.
4.3.4. Linearity grid line adjustment
The control point can shift the lines in both horizontal and vertical directions.
➢
Linearity grid line adjustment is under [3x3], [5x3] & [9x5] warp alignment menu. User can
select the control point, then press ENTER to do grid line adjustment. Each control point
can shift the image in both horizontal and vertical directions.
➢
When user projects the image to curved screen, the image grid size will continuously
change
—the grid size at the center will be bigger than both sides. Ultra-short throw
projector will be more serious. Linearity grid line adjustment is designed to correct this kind
of grid line gap difference.
➢
Linearity Grid Line adjustment can shift both horizontal and vertical grid lines. The
maximum adjusting points in OSD menu is H=9, V=5. For [3x3], the adjusting range is
+_600 pixels in each direction. This function is not available in Gwarp3 PC tool.