SUPREMA 2001 - OPERATION & SERVICE MANUAL
Page 40 of 60
July 6, 2001
Suprema 2001 - Operation & Service
MESSAGE
POSSIBLE CAUSE
CORRECTIVE ACTION
ENTER SET-UP
SET TEMPERATURE
The rear board is set for a mechanical
thermostat, but the machine is
equipped with an electronic
temperature probe.
(
Go to the “
SET TEMPERATURE
” menu and
set the electronic temperature probe.
INCOMPATIBLE
SOFTWARE LEVEL
The software version (EPROM) in the
Data Link downloader in not compatible
with this equipment and will be
downloaded.
(
Replace the software version (EPROM)
with one that is compatible with the
Suprema model. The words “
SUPREMA
”
will be printed on the EPROM decal.
PLEASE CALL FOR
ROUTINE SERVICE
This message is a reminder that regular
maintenance may be due and will not
stop the operation of the coffee maker.
(
The coffee maker is due for routine
maintenance.
(
To reset the message, enter the
"
SET
-
UP
"
and reset the service counter.
PLEASE CHECK
BREWER HARNESS
The brewer harness is not connected to
the rear board.
(
Connect the brewer harness to the rear
board.
PLEASE CHECK
OVERFLOW HARNESS
Overflow harness is not connected to
the rear board.
(
Connect the overflow harness to the rear
board.
PLEASE CHECK
TANK HARNESS
The water tank harness is not
connected to the rear board.
(
Connect the water tank harness to the
rear board.
PLEASE CHECK
WATER SOURCE
Indicates a problem with the main water
supply not getting to the water tank.
(
At this point, the water tank is not full
and this message has to be reset. To
reset it, switch the power off and on.
(
If the problem persists, check all
components on the water line (water
filter, tubing, fittings, etc.).
(
Check inlet valve to make certain it is
functioning properly.
(
In the case of a temporary disruption
with the water supply, the coffee maker
will reset itself after every hour.
PRESS PRODUCT
TO RESET MESSAGE
The "
OPEN BREWER
" button has been
pressed.
(
Pressed the "
OPEN BREWER
" button once
more to close the brewer and exit.
(
At this point, pressing the appropriate
buttons on the front selection panel will
reset the product counters.
PROBES
CALL FOR SERVICE
The main level probes are covered with
lime/calcium.
(
The water tank may require deliming.
(
The main level probes need to be
cleaned/delimed.
SELECTION
NOT AVAILABLE
Product selected may be disabled.
(
Check the "
ENABLE SWITCHES
" menu to
see if product has been canceled.
(
Check the price of the selection to make
certain it has not been disabled (set
below zero).