background image

CARAT

TECHNICAL MANUAL

TM_EN

Part No.: 1764016_01
Date: 150413

Содержание CARAT 1GR

Страница 1: ...CARAT TECHNICAL MANUAL TM_EN Part No 1764016_01 Date 150413 ...

Страница 2: ...andling of the machine 14 Changing the group gasket 14 STORAGE AND DISPOSAL OF MACHINE 15 How to store the machine 15 Disposal of machine 15 PROGRAMMING 16 Electronic control panel 16 Button functions 16 Aditional capabilities reachable from the display 17 Programming the coffee dosage 18 Programming of hot water volume 18 Programming temperature for the turbo steamer 18 Maximum security time 19 A...

Страница 3: ...iler temperature 32 Multi boiler setting 32 Groups temperature 32 Offset temperature set 33 PID parameters 33 Water softener filter Regeneration 33 MESSAGES AND ALARMS 34 TROUBLESHOOTING 35 ELECTRICAL DIAGRAM 36 Display board and IO Board outputs 1Gr 230V 1 N 36 Display board and IO Board outputs 2Gr 230V 1 N 37 Display 2Gr TS Orchestra 400V 3 N 38 Display 2Gr 3 boilers 39 WATER SYSTEM 40 Machine ...

Страница 4: ...ant Alerts against unsafe practices Observe to ensure drink quality machine performance food safety to prevent minor personal injury or damage to the machine WARNING Indicates a potentially hazardous situation which if not avoided could result in scalding serious injury and even death DANGER INDICATES A IMMINENTLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN SERIOUS INJURY AND EVEN DEAT...

Страница 5: ...dard Turbo Steamer Steam wand 2pcs 1pc Hot water outlet 1pc 1pc Turbo steamer None 1pc Electronic temperature control Yes Temperature control by group Yes Programmed via display Yes Stand by mode Yes Height width depth 620 586 563mm Boiler volume 6L Power supply 220 240V 1N 2850W 50 60 Hz Water connection 3 8 Internal thread Machine weight kg 45kg Steam boiler operating pressure Between 0 8 and 1 ...

Страница 6: ... water outlet 1pc 1pc Turbo steamer None 1pc Electronic temperature control Yes Temperature control by group Yes Programmed via display Yes Stand by mode Yes Height width depth 620 774 563mm Boiler volume 11 5L 11 5 2x1 5 L Power supply 220 240V 1N 3200 W 50 60 Hz 220 240V 1N 3250 W 50 60 Hz 380 415V 3N 4850W 50 60Hz 380 415V 3N 4850W 50 60Hz Water connection 3 8 Internal thread Machine weight kg ...

Страница 7: ...NENTS Front view of the machine Carat 1GR Steam lever Display Hot water button Steam button Drink buttons Pump Manometer Turbo Steamer Steam Manometer Hot water outlet Porta filter Brewing group Steam wand Main switch Cup shelf ...

Страница 8: ...MPONENTS Front view of the machine Carat 2GR Steam lever Steam button Display Steam button Drink buttons Pump manometer Steam wand Steam manometer Hot water outlet Porta filter Brewing group Steam wand Cup shelf Main switch ...

Страница 9: ...s with the regulations in force in the country of installation You should protect the electric line of the installation with a circuit breaker switch appropriated for the power consumption of the machine specified on its ratings plate A residual current circuit breaker must be installed in accordance with the characteristics of the area of the installation Check the characteristics power rating of...

Страница 10: ...box of the machine Connect one end of the corrugated tube to the drain cup in the machine connect the other to the main drainage tube at the installation area Boiler temperature and pressure are directly related see Fig 01 Machine is fitted with a pressure gauge that will display the boiler pressure if the machine is fitted with a display it will also indicate boiler temperature Relationship betwe...

Страница 11: ...oup head and dispense hot water for one minute Steam wand Position the wand outside the drip tray and open the steam lever for around one minute Hot water outlet Place a container under the water outlet and open the lever for 20 seconds Rinse the group and porta filter without detergent only using the membrane and hot water Clean the external surfaces of the machine pay special attention to the st...

Страница 12: ...ly after press the Short Espresso button B on the button panel of the group that require cleaning When cleaning starts you may release the buttons and machine will automatically repeat the cleaning cycles 5 times until it completed Important Once cleaning process is finished remove the porta filter and run water through the group again to rinse out all remains Repeat the cleaning process this time...

Страница 13: ... Start a continuous espresso Make an opening closing movement of the porta filter in place without closing it Water will now flow around the porta filter flowing through the closing surface and cleaning it Be very careful as this water is very hot and can cause burns Leftover coffee requiring cleaning Shower plate WARNING Take special care to avoid scalding when performing this cleaning operation ...

Страница 14: ...ace the new gasket and shower B into the porta filter C Remove the shower and gasket Preheat the gasket to soften the rubber A heat the gasket for 15 seconds using the water from the hot water outlet or B place the gasket shower and porta filter in hot water for 30 seconds Remove and discard the old gasket Insert the new gasket chamfer and EXPOBAR logo facing up into the shower Important Avoid pla...

Страница 15: ...t the inlet hose from the machine to the water mains and empty the boiler this should be performed by a qualified person Clean the drip tray and exterior of the machine Cover pack the machine and store it in a dry place where it isn t exposed to bad weather conditions If the machine should be used after a long period of storage make sure to run all cleaning procedures before using the machine agai...

Страница 16: ...eys 1 short espresso 1 long espresso 2 short espresso 2 long espresso brew the programmed volume and then stop automatically the fifth key brews continously untill user stops it by pressing button again 1 Short Espresso 1 Long Espresso 2 Short Espresso 2 Long Espresso Continuous Depending on how long this button is pressed it has 3 functions Less than 1 second activates the hot water for infusions...

Страница 17: ...placing water softener filter Display language selection Auto cleaning Continuous 1 short espresso OFF ON Reset litres of water descale Stand by Only left keypad Group boiler OFF ON Continuous 1 long espresso multi boiler machines OFF ON Service reset espresso OK Publicity EXPOBAR Customizable lines Boiler water level Actual temperature of the main boiler Max hh mm day Time day o C Min T 1 T 2 96º...

Страница 18: ...ntinuous button for less than 1 second Water will dispense from the hot water wand Press the same button again to stop the dispensing and store the new volume Different water volumes can be stored in each keypad Programming of hot water volume Keep the continuous button pressed over 8 seconds all the lights in the keypad will light up and continuous button will flash Immerse the steam wand in the ...

Страница 19: ... of the week can be adjusted in the same way When all values have been adjusted and is confirmed with button 2 short espresso the display will proceed to the next menu Clock Adjust HH MM Day 1 short espresso 1 long espresso 2 short espresso OK Continuous to confirm fig C Access to second level menus Keep the continuous button pressed over 8 seconds on the left keypad Entering first level See fig A...

Страница 20: ...e will not switch on at all The day off menu will not appear if the automatic ON OFF times is not set See fig C To adjust the day OFF increase or decrease its value by pressing the button 1 short espresso or 1 long espresso When the right value is reached accept it by pressing the button 2 short espresso Auto On Off On Hh mm Auto On Off Off Hh mm 1 short espresso 1 long espresso 2 short espresso O...

Страница 21: ...flash The display will show See fig A Once again press and maintain pressed the continuous button till the display shows Clock adjust See fig B Press briefly the continuous button the display will show the option Counters See fig C A B C D This counter shows the volume of water litres that has been through the machine Its main purpose is to facilitate the control of when a regeneration of the wate...

Страница 22: ...cal service and maintenance On the second row it is shown the number of services brewed individual brewed services made by the machine since the last reset How to access From the counter Litres get to this counter by pressing the continuous button To get out and get to the next menu press the continuous button It can be programmed the number of brewed services before the electronics give the warni...

Страница 23: ...n be reset as follow While displays shows as fig A press at the same time both buttons 2 short espresso and 2 long espresso for more than 4 seconds The access to these adjustment menus is only possible from the left keyboard of the machine left facing the machine With the machine in the stand by OFF state keep pressed the continuous button for more than 15 seconds till the display shows the follow...

Страница 24: ...ccept the selection made and proceed to the next menu press the continuous button Select language CARAT Colour CARAT Mode 1 short espresso 1 long espresso 2 short espresso OK Continuous to confirm 1 short espresso 1 long espresso 2 short espresso OK Continuous to confirm 1 short espresso 1 long espresso 2 short espresso OK Continuous to confirm Fig A Fig B Fig C To accept the selection made and pr...

Страница 25: ...esso one short espresso To accept the selection made and proceed to the next menu press the continuous button In this menu See fig B we adjust the behavior of the led lines on the base of the machine To toggle the mode use the one short espresso or one large coffee buttons The leds will respond immediately to the option selected Scrolling Christmas off Fix on blinking dynamic one long espresso one...

Страница 26: ... B Fig C Now the colour of the display while in OFF state is set See fig C To toggle between the different options use the one short espresso or one long espresso The effect of the option selected can be observed directly on the machine Spanish German Italian French English one long espresso one short espresso To accept the selection made and proceed to the next menu press the continuous button He...

Страница 27: ...resso or one long espresso To accept the selected character and proceed to the next one press the button 2 short espresso To accept the line and proceed to the next menu press the continuousbrewing button In this menu See fig C it is set the telephone number shown when the warning caused by reaching the number of services set for technical maintenance To modify the selected number for the blinking...

Страница 28: ...us Only coffee cont Only Tea To modify the selected mode press the button one short espresso or one long espresso To accept the setting and proceed to the next menu press the continuous button In this menu See fig C it is set which keypad is phisically connected internally to the button of the electronic steam wand By factory default this is set to 1 and it should not be modified as malfunctioning...

Страница 29: ...ow it is adjusted the pre brewing time for the little pause after the initial water injection as to allow the grinded coffee to moisture depending on each type of selection To accept the setting and proceed to the next menu press the continuous button Here it can be adjusted the detection sensibility of the level probes of the boiler See fig D Normally it is not needed to modify it from the medium...

Страница 30: ...in this menu its parameters can be adjusted If it was disabled this menu will not appear Here it is adjusted the minimum flow rate that will be considered as inferior limit of a good brewing flowrate To increase this value press the button one short espresso to decrease it press the button one long espresso To accept the setting and proceed to the next menu press the continuous button Here it is a...

Страница 31: ...enance cycle shower screen replacing gaskets etc When the service counter reaches the number set here on the display it is shown the warning Service needed and the Phone of the service To increase this value press the button one short espresso to decrease it press the button one long espresso To accept the setting and proceed to the next menu press the continuous button To show the temperature in ...

Страница 32: ...utton Here it is adjusted the temperature for each group and the main boiler If the previous menu was set to OFF only the temperature for the main boiler will appear in this menus To increase temperature value press the button one short espresso to decrease it press the button one long espresso Group temperature1 Group temperature2 Main boiler temperature Once adjusted each temperature press the c...

Страница 33: ... having adjusted the last one when pressing the continuous button the next menu will appear Here it is adjusted the liters of water after which the electronics will warn about the need of regenerating the water softener To increase this number press the button one short espresso to decrease it press the button one long espresso In Contador Litros chapter it is shown the volume of water already use...

Страница 34: ...o C Min Service 9999999 Max o C Min Filter 999999999 Max o C Min Flowmeter X failure No flow detected in flowmeter X Check that the machine is receiving water Temperature sensor X fault Warning technical service needed The water softener filter needs to be replaced MESSAGES AND ALARMS ...

Страница 35: ...steam The steam wand is clogged by milk Clean the wand and if necessary remove the nozzle and unclog it using a pin or needle Water is found underneath the machine The drainage tube is blocked Clean the drainage tube The following checks can be carried out by users once the machine has been turned off and disconnected from the power supply For all other non specified machine faults disconnect the ...

Страница 36: ...PLY F Main PCB PN 60100420 Flow meter PN 60100045 Display module PN 2760031 8X2 5X2 8X2 4 8X2 Drink keypad PN 1264127 Electro valve PN 60000112 Motor PN 60000016 Electro valve PN 60000105 Electro valve PN 60000100 Electro valve PN 60000120 Water level sensor PN 60100040 2 T1 1 L1 4 A2 3 A1 3 1 4 2 Power Switch PN 1660036 Solid state relay PN C60800101 NTC Boiler Ref 60100076 NTC steamer Ref 601000...

Страница 37: ...er OUT 3 OUT 2 OUT 1 SLiv Vcc Gnd SLmin EvA I EvA I EvC C EvI V EvG 3 EvG 2 EvG 1 M COMMON N MAIN SUPLY F Main PCB PN 60100420 N L G Water level sensor PN 60100040 Flow meter PN 60100045 Display module PN 2760062 8X2 5X2 8X2 8X2 4 8X2 Drink keypad PN 1264124 Drink keypad PN 1264124 Electro valve PN 60000112 Motor PN 60000016 Electro valve PN 60000112 Electro valve PN 60000105 Electro valve PN 6000...

Страница 38: ...OUT 1 SLiv Vcc Gnd SLmin EvA I EvA I EvC C EvI V EvG 3 EvG 2 EvG 1 M COMMON N MAIN SUPLY F Main PCB PN 60100420 N Water level sensor PN 60100040 Flow meter PN 60100045 Display module PN 2760062 8X2 5X2 8X2 8X2 4 8X2 Drink keypad PN 1264124 Drink keypad PN 1264124 Electro valve PN 60000112 Motor PN 60000016 Electro valve PN 60000112 Electro valve PN 60000105 Electro valve PN 60000100 Electro valve ...

Страница 39: ... COMMON N MAIN SUPLY F Main PCB PN 60100420 N Water level sensor PN 60100040 Flow meter PN 60100045 Display module PN 2760062 8X2 5X2 8X2 8X2 4 8X2 Drink keypad PN 1264124 Drink keypad PN 1264124 Electro valve PN 60000112 Motor PN 60000016 Electro valve PN 60000112 Electro valve PN 60000105 Electro valve PN 60000100 Electro valve PN 60000120 Resistance 4500W 230V 2GR PN C38045000F Capacitor 0 47uF...

Страница 40: ...CARAT 40 WATER SYSTEM Machine with 1GR Cold water Hot water Drain waste water ...

Страница 41: ...CARAT 41 WATER SYSTEM Machine with 2GR Cold water Hot water Drain waste water ...

Страница 42: ...CARAT 42 EXPLODEDVIEW Machine with 1GR Drawing 4 3 10 29 28 30 1 2 5 7 8 6 25 11 13 14 15 19 20 16 17 18 31 32 33 21 34 23 24 22 9 26 27 35 12 ...

Страница 43: ...Cover 14 1 260720 Group Cover Support Carat 15 1 260674 Cup Holder Carat 16 1 1264104 Front Brand Panel 17 1 1264167 Front brand panel 1Gr black 18 1 260716 Drip Tray 1GR Carat 19 1 260717 Grid Carat 1Gr 20 1 260710 Front Panel 1GR Carat 21 1 1264092 Right panel lower white 22 1 1264165 Right panel lower black 23 1 1264091 Right panel upper white 24 1 1264164 Right panel upper black 25 1 260719 To...

Страница 44: ...CARAT 44 EXPLODEDVIEW Machine with 2GR Drawing 3 4 5 1 2 6 8 9 7 11 10 12 15 25 21 22 20 19 18 26 28 32 33 29 35 34 17 16 23 24 13 14 27 31 30 ...

Страница 45: ... 2Gr white 14 1 1264166 Front brand panel 2Gr black 15 1 260731 Drip Tray 2Gr Carat 16 2 260674 Cup Holder Carat 17 1 260700 Grid Carat 2Gr 18 1 260729 Front Panel 2Gr Carat 19 1 260715 Right Lower Panel Cover 20 1 260714 Right Upper Panel Cover 21 1 1264091 Right panel upper white 22 1 1264164 Right panel upper black 23 1 1264092 Right panel lower white 24 1 1264165 Right panel lower black 25 1 1...

Страница 46: ...CARAT 46 6 EXPLODEDVIEW Rotary pump Drawing 2 3 9 7 8 4 1 5 10 11 ...

Страница 47: ...6 DIN 934 3 4 C50100000 SILENTBLOCK M 6 4 1 C30000019 CARDAN JOINT PUMP 5 1 C60000031 Piston Bypass Pump Tec 6 1 C60000030 Pump Crem Special Treatment 7 1 C65000010 RetentionValve 3 8 1 8 Min Mon Ec 8 1 C30400055 Pump Bypass Condor 9 1 C30100100 Inlet Water Filter Holder 10 1 C70000009 Tubular Group Filter 11 1 C30000240 PUMP ADAPTOR 3 8 X 3 8 ...

Страница 48: ...CARAT 48 EXPLODEDVIEW Boiler 1GR Drawing 1 11 12 13 14 7 8 16 17 18 9 6 4 5 5 3 2 10 15 ...

Страница 49: ...4 7 1 C60100076 Temp Probe Susp Steam Pipe Icd 8 1 C65000200 Non SuctionValve 9 1 C65000100 3 8 SafetyValve 10 1 C30000110 3 Tracks Adaptor 1 4 1 4 1 8 11 3 C25093320 Hexagonal Head Screew 8X20 Din 933 12 3 C25012530 Flat Washer M 8 Din 125 13 1 C38025001F 2500W 230V 6Ltrs Copper Element with fuses 14 1 C50010030 40 52 2 Element Teflon Gasket 15 1 C15100018 Boiler Copper 1Gr 6L 16 1 C30000210 Ther...

Страница 50: ...CARAT 50 EXPLODEDVIEW Boiler 2GR Drawing 13 15 14 14 16 11 3 4 6 7 5 8 9 10 12 1 2 17 18 12 ...

Страница 51: ...0030 40 52 2 ELEMENT TEFLON GASKET 8 1 C38027000F 3050W 230V 2gr ELEMENT with fuses 9 3 C25012530 FLAT WASHER M 8 DIN 125 10 3 C25093320 HEXAGONAL HEAD SCREEW 8x20 DIN 933 11 1 C30000315 BLING PLUG 1 8 FEMALE 12 4 C50010010 21 1 25 7 1 2 TEFLON GASKET 13 1 C65000200 NON SUCTIONVALVE 14 2 C30000003 REDUCER MALE FEMALE 3 8 1 4 15 2 C30000200 THERMICS SUP ADAPTOR 1 2 X 1 2 16 1 C60100076 TEMP PROBE S...

Страница 52: ...CARAT 52 Drawing 21 14 13 12 11 10 08 07 06 05 03 02 01 04 09 15 17 20 19 18 16 2Gr 3 Boilers boiler assembly main boiler EXPLODEDVIEW ...

Страница 53: ...Valve 11 2 C50010010 21 1 25 7 1 2 Teflon Gasket 12 1 C30000100 2 Tracks Adaptor 1 4 X 1 8 13 1 C38027000F 3050W 230V 2Gr Element with fuses 13 1 C38045000F 4500W 230V 2GR Element with fuses 14 1 C50010030 40 52 2 Element Teflon Gasket 15 1 C15100020 Boiler 2Gr 11Lts 15 1 C15100030 Boiler 3Gr 17Lts 16 2 C30200035 Long Plug 1 2 Group 17 1 C25679812 M12 Washer Form A 18 1 C25000003 Inox Ground Washe...

Страница 54: ...llen Screw 4X12 Din 912 04 1 C10200110 Office Thermostat 16 A 05 1 C30000290 Plug M 3 8 06 1 C38012000 1200W 230V Office Element 07 2 C30000300 Blind Plug 1 4 Male 08 1 C15100010 Office Cappuccinator Boiler 09 1 C60100076 Temp Probe Susp Steam Pipe Icd 10 2 C50010010 21 1 25 7 1 2 Teflon Gasket 11 2 C30000200 Thermics Sup Adaptor 1 2 X 1 2 12 1 1260017 Insulation Boiler Office 11 05 03 02 01 04 06...

Страница 55: ...CARAT 55 EXPLODEDVIEW Turbo steamer Drawing 18 1 3 7 12 16 17 9 10 11 13 4 5 6 15 20 19 14 8 2 21 ...

Страница 56: ...ter 8 1 C60100075 Steam Temperature Sensor 9 1 C50010080 Gasket Tap Steam Water Teflon 10 1 C30370076 Spring Steam Water Tap 11 1 C30370077 Gasket Tap Steam Water Brass 12 1 C30500005 Male Hose Adapter Elow 13 1 C30370075 O Ring For Steam Tap 14 0 35m C35021000 Silicon Hose DIA4 7mm 15 1 C30370190 Nozzle steam tap 1H M8 5 with oring 16 1 C50010090 O Ring 6X1 17 1 C30370195 Nozzle Steam Tap 3H M8 5...

Страница 57: ...CARAT 57 2 4 EXPLODEDVIEW Steam wand Drawing 1 3 5 8 7 6 9 15 17 16 19 20 21 10 12 11 14 13 18 ...

Страница 58: ...G1 2 Male G5 8 8 1 C30370164 Holder washer 9 1 C15000338 Tap Body and Steam Knob 10 1 C50000133 O ring 10 77x2 62 11 1 C30370163 Extension axle for tap 12 1 C55000070 Spring 14X24x1 5 OA2 13 1 C30370166 Connector 3 4M x G14M 14 1 C50010070 Teflon gasket 19X24x2 15 1 C50010080 Gasket Tap Steam Water Teflon 16 1 C30370076 Spring Steam Water Tap 17 2 C30370077 Gasket Tap Steam Water Brass 18 1 C50000...

Страница 59: ...CARAT 59 EXPLODEDVIEW Hot water outlet Drawing 1 2 3 4 5 6 7 11 12 8 9 10 ...

Страница 60: ...V 3 1 C30100010 Hexagonal Nut 1 4 Pressostat 4 1 C30000236 Elbow Racor G1 4Xg3 8 5 1 C50010080 Gasket Tap Steam Water Teflon 6 1 C30370076 Spring Steam Water Tap 7 1 C30370077 Gasket Tap Steam Water Brass 8 1 C30370075 O Ring 12 1X2 7mm 9 1 C70000010 Nut 3 8 For Steamer 10 C30000050 Nozzle Water Tap Complete 11 C30370080 Water Tap Classic 12 1 C30370081 Water Tap Connector Kit ...

Страница 61: ...CARAT 61 EXPLODEDVIEW Group head Drawing 1 7 15 14 13 2 8 3 9 4 16 11 5 12 6 10 ...

Страница 62: ...026 Tefl Water Reduc Holder 4X6x65 6 1 C25091250 Allen Screw 6 10 Din 912 Group 7 1 C30200010 Crem Brewing Group Body 8 1 C30200040 Diffuser 9 1 C75000010 Shower 10 1 C60000112 Gro Head Electrov Parker 220V 11 1 C30700000 6Mm Barbfitting 1 8F 12 1 C75000081 8Mm Group Head Gasket 13 1 C50020020 2 5 18 2 2 Teflon Hot Water Reducto 14 1 C50000010 Green Body Flat Group Joint 15 1 C50000100 O Ring 6 07...

Страница 63: ...CARAT 63 EXPLODEDVIEW Lower water system Drawing 6 7 8 9 10 11 12 3 4 2 13 5 1 ...

Страница 64: ...4 1 1364021 Copper Tube Φ8 0 100mm 1Gr 5 2 C60100045 FLOWMETER UL NETW BRASS TEF LED 6 1 C60000105 50 60HZ 220V SOLENOID ELECTROVALVE 7 2 C25091210 ALLEN SCREW 4x12 DIN 912 8 1 C50000110 SMALL AUTOFILL SOLENOID GASKET 9 1 C50000105 LARGE AUTOFILL SOLENOID GASKET 10 1 C30100010 HEXAGONAL NUT 1 4 PRESSOSTAT 11 1 C30000215 CONICAL BEND ADAPTOR 1 4 X 1 4 12 1 C30100010 HEXAGONAL NUT 1 4 PRESSOSTAT 13 ...

Страница 65: ... POS PCS Part No Description 1 1 C75000031 1 Cup Filter 7Gr 2 2 C75000120 Filter Spring 3 1 C75000050 Spout 1Cup 4 1 C75000041 2 Cup Filter 14Gr 5 1 C75000060 Spout 2Cups 6 1 2760126 Filter Handle Assy 1 Cup 7 1 2760127 Filter Handle Assy 2 Cup 6 7 1 2 3 4 2 5 ...

Страница 66: ...WING PART NO MODEL NAME C60100420 Main control box C60100049 Adjustable Unit Trimmer C60000072 Manometro D40 0_16 BAR C60000062 Manometro D40 0_2 5 BAR C60100045 Flowmeter UL Red TEF Led 1660097 Contactor 230V LC1D18P7C EXPLODEDVIEW ...

Страница 67: ...nts DRAWING PART NO MODEL NAME 1660036 Power Switch Blue Φ22mm C60800103 Solid State Relay Cover C60800101 STATIC RELAY 4 32 C70001001 C70001005 Drain cup with thread Drain cup cover 260177 DIN Connection SS 65MM EXPLODEDVIEW ...

Страница 68: ...ristaltic Pump with Harness 1666032 Harness NTC Extension 1666039 1666061 Signal cable Long Cable Signal Carat C16660028 Harness complete Carat 1Gr C16660029 1666042 Harness complete Carat 2Gr Harness complete Carat 2Gr 3phase C60102020 O ring flowmeter EXPLODEDVIEW ...

Страница 69: ...hanical Type 2 Buttons 5 1 C60101060 Graphic Display Gicar 6 1 1264128 Display PCB Box Bottom 2 Buttons 7 1 1264129 Display PCB Box Upper 2 Buttons 8 1 2760031 Display PCB Assembly Carat 9 1 C 60101512 METAL BUTTON SET COVER x5 10 1 1264107 Display PCB Box Upper Carat 11 1 1264108 Display PCB Box Bottom Carat 12 1 1264095 Conductive Control Button 13 1 C60101060 Graphic Display Gicar 14 1 1660039 ...

Страница 70: ...rts list POS PCS Part No Description 1 1 1264124 Button Box Assy Carat 2 1 C 60101512 METAL BUTTON SET COVER x5 3 1 1264126 Button Box Upper 4 1 1264095 Conductive Control Button 5 1 1264125 Button Box Bottom 6 1 1660039 PCB Mechanical Type 5 Buttons 2 3 4 5 6 ...

Страница 71: ...service if there is any risk that the damage or defect would worsen The warranty will not cover consumption supplies such as glassware normal maintenance such as cleaning of filters contaminations in water lime incorrect voltages pressure or adjustment of water amounts The warranty will not cover damages of defects caused by incorrect handling and operation of the appliance Models coverd by this m...