SUPREMA 2001 - OPERATION & SERVICE MANUAL
Suprema 2001 - Operation & Service
July 6, 2001
Page 15 of 60
TOTAL COUNTER RESET
This software contains a special access code that enables the service person to reset all
the counters to zero, including the "
VEND TOTAL
" counter. This operation should be
performed before a unit is re-installed in the field.
1.
To perform a "
TOTAL COUNTER RESET
",
a)
Switch the power to the coffee maker "
OFF
" (switch is at the rear of the
unit).
b)
Press the "
SET
-
UP
" mode button on the inside door panel and keep it
depressed.
c)
With "
SET
-
UP
" mode button pressed, switch power to coffee maker "
ON
".
d)
The following message will now appear on the display,
e)
Enter the "
TOTAL COUNTER RESET
" access code (described below).
"TOTAL COUNTER RESET" ACCESS CODE
The following is the factory preset "
TOTAL COUNTER RESET
" access code - press the
following in the sequence outlined below;
1 COFFEE
2 MILD
STRENGTH
3 LARGE
CUP
4 MEDIUM
CUP
5 SMALL
CUP
Once the access code has been entered, a counter will appear on the top left of the
display, and will quickly increment from 0 to 255. Once this is complete, press
“
START
” for the brewer to cycle once to re-establish its home position.
ENTER ACCESS
CODE:
!
Note:
When the reset is
complete, the unit
will automatically
exit to the
“standby” mode,
and the internal
light will remain
“
ON
” temporarily.