Specifications

The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)

The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)

Load Rating............................................... 1 amp per terminal, 1.5 amp 

                                                                      maximum all terminals combined

Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚

                                                                             Cooling is adjustable from 0.2˚ to 2.0˚

Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz 

                                                                      for hardwire

                                                                      Battery power from 2 AA Alkaline 

                                                                      batteries

Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)

Operating humidity .............................. 90% non-condensing maximum

Dimensions of thermostat ................. 4.7” W x 4.3” H x 1.1” D

29

30

Specifications

Features

Temporary Hold: 

The thermostat will display 

HOLD

 and 

Run 

Schedule 

on the bottom of the screen when you press the         or         

key. If you do nothing, the temperature will remain at this setpoint 

temporarily for 4 hours. The program setpoint will then replace the 

temporary setpoint.

Permanent Hold:

 With a temporary hold set, If you press the 

Hold 

key at the bottom of your screen, you will see 

Hold

 appear next to 

the setpoint temperature in the display. The thermostat will now 

permanently stay at this setpoint and can be adjusted using the  

         or         keys.

To Return To Program: 

Press the 

Run Schedule 

key at the bottom of 

the screen to exit temporary and permanent holds.

Temporary & Permanent Hold Feature

Filter Change & Other Reminders

If your installing contractor has configured the thermostat to remind 

you when the air filter needs changed, you will see a reminder in 

the display when your air filter needs changed. the reminder will 

be shown in the display after your system has run long enough to 

require an air filter change.

Resetting the filter change reminder:  When

 

the reminder is 

displayed, you should change your air filter and reset the reminder by 

holding down the “

Clean

” key on the left side of the thermostat for 3 

seconds.  This thermostat also has other maintenance reminders 
( Humidity Pad, UV Lamp, and IAQ Cell ), that are reset with the same 
procedure.

Remote Sensor Operation

Option #1 - Indoor / Local Temperature Sensor “ON”:

1. 

The displayed room temperature will display the average

 temperature of the thermostat and all remote sensors.

2.

 By pressing the lower left hand corner of the screen, the average 

temperature of just the remote sensor(s) will be displayed briefly in 

the clock field.

Option #1 - Indoor / Local Temperature Sensor OFF”:

1. 

The displayed room temperature will only show the average 

temperature of the remote sensor(s).

Option #2 - Outdoor:

1. 

The outdoor temperature will alternate briefly with the clock 

display.

Option #3 - Floor:

1.

 By pressing the lower left hand corner of the screen, the 

temperature of the floor sensor will be displayed briefly in the clock 

field.

Remote Sensor Operation Options

31

Содержание TP-S-955CR

Страница 1: ...sh with the wall 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good...

Страница 2: ...mpressor delay feature is active if these icons are flashing The compressor will not turn on until the 5 minute delay has elapsed Setpoint Displays the user selectable setpoint temperature HOLD is dis...

Страница 3: ...calCool OnlySystem HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY COMPRESSOR RELAY C R L2 L1 HOT RC RH Y C G Power supply Factory installed jumpe...

Страница 4: ...ation is adjustable A smaller swing setting will cause more frequent cycles and a larger swing setting will cause fewer cycles Cooling Swing The cooling swing setting is adjustable from 0 2 to 2 For e...

Страница 5: ...fan during a call for heat Select ELEC to have the thermostat control the fan during a call for heat Fan Operation GAS or ELEC GAS GAS FAN SET Reminders Once a reminder has been turned on and set the...

Страница 6: ...D1 OCCUPIED 2 UNOCCUPIED 2 Repeat steps 4 through 7 for the remaining days of the week A Note About Auto Changeover In Auto you have the ability to switch between Auto Heat or Auto Cool by pressing th...

Страница 7: ...ith the fan key 5 Then use the or key to make your setpoint selection for the weekday OCCUPIED period 6 Press Next 7 Repeat steps 4 through 7 for the weekday UNOCCUPIED time period To customize your 5...

Страница 8: ...porary Permanent Hold Feature Filter Change Other Reminders If your installing contractor has configured the thermostat to remind you when the air filter needs changed you will see a reminder in the d...

Отзывы: