Owner’s Manual
Your new SunStat Dial thermostat
is designed to control the voltage to
either a 120VAC or 240VAC resistive floor warming system.
Please follow this manual for complete installation and operation instructions.
If you have any questions or comments, try calling Technical Support at
1-800-276-2419.
CAUTION
: Make sure you are qualified and are familiar with house wiring.
This is a line voltage device that could cause serious injury or damage if
improperly installed.
SunStat Dial
Dial Thermostat
Model 500710
1. Preparation
1.
Unpack your thermostat and make sure everything is in good condition:
•
Thermostat
•
Floor sensor
•
Small screwdriver
•
Mounting screws
•
Wire nuts for wiring connections
If any parts are missing or damaged, contact the store where you purchased
this thermostat. Do not install a damaged part.
2.
Gather the following tools and supplies:
•Phillips screwdriver, hole saw
•Wire strippers, “fish tape”, other electrical tools
•Electrical box for thermostat:
a.
If you are connecting to power leads from only 1 or 2 floor warming
systems, you may use a single-gang, 3
1
⁄
2
inch deep box.
b.
If you are connecting to power leads from 2 or 3 floor warming systems,
use a 4x4x2
1
⁄
8
inch or deeper box (not a 2-gang box) when your wall studs
are still exposed. Install a single-gang “mud-ring” cover on the box before
installing drywall materials.
c.
For more than 3 floor warming systems or other layouts, you may need
to install a junction box. See the installation instructions for your floor
warming system for more information.
ALWAYS
: Wire all circuits as Class 1, Electric Light and Power Circuits.
ALWAYS
: Wire all circuits with insulation rated 600V minimum.
ALWAYS
: Mount this control only to a grounded metallic box or a
nonmetallic box.
ALWAYS
: Use power supply wires suitable for at least 90°C.
CAUTION
: High voltage – disconnect power supply before servicing.
CAUTION:
The GFCI in this control does not protect against shock if both
bare conductors are touched at the same time.
2. Installation
Remove the Thermostat Face
1.
Remove the thermostat Front Module
from the Power Module by opening the
door and loosening the screw.
2.
Pull outward near the bottom on the
Front Module and lift off. Be careful not
to bend or damage the 14-pin electrical
connector on the back of the Front
Module. bottom on the Front Module
and lift off.
Prepare the Wiring
1.
Find a location for your thermostat. It is suitable for indoor use only, on
insulated or uninsulated walls. Locate it about 4
1
⁄
2
feet to 5 feet above the
floor on an inside wall. Make sure it is well ventilated and not located in a
confined space such as a small closet or cabinet. Avoid placing it near other
heat sources such as hot-water piping, heat duct, wall-mount lighting, and
direct sunlight to help prevent adversely affecting the thermostat.
2.
Turn off the power to the floor warming system at the main circuit panel
before doing any electrical work.
3.
A qualified electrician should run a dedicated circuit from the main circuit
panel to the thermostat location.
4.
If a dedicated circuit is not possible, you may tap from another circuit in the
room. Make sure there is enough load capacity (amps) to handle the addition
power
module
front
module
5
sensor
Connect Wires
1.
Match and connect the two
wires marked “LINE1” and
“LINE2” to the power supply wires
using the wire nuts provided.
2.
Gently tug on the wires to
make sure they are secure,
otherwise a wire could loosen
and cause failure.
3.
Overwrap the wire nuts with
electrical tape to better secure
them to the wires.
4.
Match and connect the two
wires marked “LOAD1” and
“LOAD2” to the floor warming
system lead wires and secure
these wires the same way.
5.
Connect the house ground
wire to the green or bare lead
wire(s) of your floor warming
system.
6.
Insert the ends of the floor
sensor wire into the “SENSOR”
terminals (1 and 2) and tighten
the screws. There is no polarity,
so it does not matter which wire
end goes into which terminal.
CAUTION:
Before continuing,
make sure your power supply
voltage matches the voltage
rating of your floor warming
system.
Connecting 240V to a 120V floor
warming system will cause over-
heating and damage to the system and may damage the control, other wiring,
floor coverings, etc.
SunStat Relays
1.
If you want to use your thermostat to drive a SunStat Relay(s) (ask
your dealer about this convenient way to control larger systems with one
thermostat), first read and follow the instructions for the SunStat Relay
thoroughly.
2.
Pull 2-conductor wire, size 18- to 24-gage, through the wall from the
SunStat Relay, into this electrical box. This wire may be up to 100 feet (30 m)
in length from the thermostat to the last SunStat Relay installed.
3.
Connect the wire ends into the “RELOUT” terminals (3 and 4) and tighten
the screws (Observe polarity of the wires when connecting to the SunStat
Relay).
Mount the Thermostat
1.
Carefully fold and press the wires back into the electrical box. Do not use
the thermostat to push them in, as this may
cause connections to loosen and possible
failure.
2.
Secure the thermostat Power Module into the
box with the mounting screws provided.
3.
Carefully snap the Front Module onto the
Power Module. Be careful not to bend or
damage the 14-pin electrical connector on the
back of the Front Module.
4.
Tighten the screw.
5.
Switch on the power at the main circuit
panel.
NOTE to contractors:
After installing the
thermostat, be sure to:
a.
Switch on the thermostat and turn up
the temperature to make sure it
is heating for a few minutes (section 3)
b.
Test the GFCI (section 3).
1-4
from
power
supply
to
floor
warming
system
of your floor warming system, and that it is NOT wired in series with any other
device, including other GFCIs.
5.
The circuit breaker in the main circuit panel should be 15 amps maximum
for a floor warming system totaling 12 amps or less. For larger systems up
to 15 amps, use a 20 amp maximum circuit breaker. Never exceed 15 amps
on this thermostat. You may consider using an arc-fault (AFCI) type circuit
breaker for additional protection.
6.
Pull the power supply wiring into this box, leaving about 6 inches of wire.
7.
Pull the floor sensor wire and the power lead wires from your floor warming
system up the wall, into this box. Refer to your floor warming system
installation instructions for placement of the floor sensor tip into the floor area.
Note:
The sensor wires should not be run in the same conduit as line voltage
wires to avoid possible interference. If the sensor lead wires are not long
enough, they may be extended an additional 15 feet (4.5 m) using minimum
20-gage 2-conductor wire or up to 50 feet (15 m) using shielded wire.
8.
Mount the electrical box.