MANUAL

0197

Digital Temple

Thermometer

Model KD-2220

IMPORTANT !

Read instruction manual

before using themometer

 

 

 

 

 

..................2

Parts Identification...........................4

Preparation  for  Use.........................5

How  to  Operate  the 

Thermometer...................................6

Memory Mode..................................8

Cleaning and Care..........................10

Troubleshooting and Special

Indications.....................................11

Specifications  ...............................12

Limited   Warranty...........................13

FCC  Statement..............................14

 

Quick Start

         POWER SOURCE

SIZE AAA  1.5V x 2  (included)

                         WARRANTY:

ONE YEAR FROM THE DATE OF PURCHASE 

                    (excluding batteries)

...

w

o

n

K

 

o

s

g

n

i

h

T

 t

n

a

tr

o

p

m

I

1. Install batteries into the thermometer making

    sure the polarity is correct.

2. Press and release the POWER button.  Unit

    will beep once.  Wait until it beeps again

    twice and only °F shows in the display.

Do not place the probe to the temple before the

2 beeps or while the hour glass is still displayed 

3. Place and hold the thermometer probe

    firmly to the skin at the temple, wait several

    seconds for the device to beep once more.

Once you place the probe to the temple, there is

no need to press the POWER button again. Doing 

so will turn the unit off.

4. Read the temperature on the display.

1.   Use the thermometer to measure your

      temple temperature only, the area be-

      tween the outer corner of the eye and

      the hairline, over the temporal artery.

2.   Do not place the thermometer on 

      scarred tissue, open sores or

      abrasions.

3.   Using drug therapies can raise skin

      temperature, which may lead to

      incorrect measurements.

4.   Do not dismantle the unit except to

      replace the batteries.

5.   Children should not use the ther-

      mometer without adult supervision.

6.   Do not drop or expose thermometer

      to electric shock as this may adversely

      affect its performance.

7.   The thermometer is not waterproof.

      Do not immerse it in water or liquid of

      any kind.

8.   To ensure correct readings, wait at 

      least 2 minutes between continuous

      measurements for the thermometer

      to return to room temperature.

9.   Do not use the thermometer around

      flammable materials.

10. Stop using the thermometer if

      malfunctions appear or if it operates

      abnormally.

11. Clean the thermometer probe after

      each measurement.

12. Do not take a measurement if the 

      temple area has just been exposed

      to direct sunlight, fireplace heat or air

      conditioner flow, as this may lead to

      incorrect readings.

13. If thermometer has been kept or 

      stored in a cold temperature, please 

      wait at least 1 hour for it to return to 

      room temperature before measuring.

14. Performance of the thermometer may 

      be degraded if the unit is operated or 

      stored outside the stated temperature 

      or humidity ranges, or if the patient’s 

      temperature is below room temp.
15. Body temperature, like blood pressure,

      varies from person to person.  During

      the day, it can range from 95.9°F to

      100.0°F (35.5 to 37.8°C).  For some

      people there can be a difference be-

      tween their temple and body temp. 

      We recommend learning what your

      normal temple temperature is while

      healthy so you can detect an elevated

      one when you become ill.  For

      accuracy, be sure to measure the 

      same area of the temple each time.
16. Avoid taking a measurement for at 

      least 30 minutes after physical 

      exercise, bathing or eating.

17. Make sure the temporal area is dry

      and clean of sweat, make-up, etc.

19. Calibration is recommended every

      two years.

 

 

 

 

Important Things to Know

Important Things to Know

18. The device is intended for consumer

      use only.

Содержание KD-2220

Страница 1: ...INSTRUCTION MANUAL 0197 Digital Temple Thermometer Model KD 2220 IMPORTANT Read instruction manual before using themometer ...

Страница 2: ...I 1 Install batteries into the thermometer making sure the polarity is correct 2 Press and release the POWER button Unit will beep once Wait until it beeps again twice and only F shows in the display Do not place the probe to the temple before the 2 beeps or while the hour glass is still displayed 3 Place and hold the thermometer probe firmly to the skin at the temple wait several seconds for the ...

Страница 3: ...ut adult supervision 6 Do not drop or expose thermometer to electric shock as this may adversely affect its performance 7 The thermometer is not waterproof Do not immerse it in water or liquid of any kind 8 To ensure correct readings wait at least 2 minutes between continuous measurements for the thermometer to return to room temperature 9 Do not use the thermometer around flammable materials 10 S...

Страница 4: ...ressure varies from person to person During the day it can range from 95 9 F to 100 0 F 35 5 to 37 8 C For some people there can be a difference be tween their temple and body temp We recommend learning what your normal temple temperature is while healthy so you can detect an elevated one when you become ill For accuracy be sure to measure the same area of the temple each time 16 Avoid taking a me...

Страница 5: ...know your normal body temperature range Therefore we recommend you measure yourself when healthy to establish referenced temperatures which will make you feel more confident of the measured temperature readings when ill 1 Pull the battery cover off in the direction shown 2 Prior to installing new batteries you must clean the metal contact ends of the batteries and the metal springs and contacts fo...

Страница 6: ...tteries at the same time Do not mix old and new ones 2 Never mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries 1 Do not dispose of batteries in regular household trash refer to your local disposal laws and manage as hazardous waste 2 Do not recharge put in backwards disassemble or dispose of batteries in fire Doing so may result in explosion leakage and injury ...

Страница 7: ... If the temperature reading is over 99 5 F 37 5 C eight consecutive beeps will be heard to indicate fever alarm 37 1 37 2 37 4 37 5 AND UP 98 9 99 4 99 5 AND UP Green Yellow Red 98 8 UPTO UPTO Measurement Temperature in F Measurement Temperature in C Back Light Color 4 Put the thermometer on the temple It will beep one time to present measurement completion 5 The display will light according to th...

Страница 8: ...ent However we do not recommend consecutive measurements 8 Turn off the unit by pressing the POWER button or the unit will automatically turn off and beep after 1 minute of inactivity Switching between Fahrenheit and Centigrade Scale You can switch between F and C scales Within 3 seconds after turning on the device again press and hold the POWER button The display will show CH with F or C F Mode C...

Страница 9: ...e most recent memory is shown then release 3 Press and release the button again and again to scroll through the remaining previous memories Etc 4 When you are finished viewing stored memories discontinue pressing the button After a short pause you will hear 2 beeps indicating the unit is ready to take a new measurement Ready to measure ...

Страница 10: ...ies it is simply an option Oldest memories will automatically be deleted as you take new measurements Removing the batteries will also delete all memories from the unit NOTE ALL memories will be deleted in this process you cannot delete just one single memory 2 While dEL is still displayed press and release the POWER button once more to finish the delete process OFF will show on the display and al...

Страница 11: ...unit to readjust to room temperature before taking another measurement If necessary use only a soft cloth to clean the body of the thermometer Avoid using thinner benzene or other harsh cleaners Do not use an abrasive cleanser and NEVER submerge the thermometer in water or any other liquid Remove the batteries if the thermometer will not be used for a long period of time Do not expose the unit to ...

Страница 12: ...mometer will power off automatically Please measure again 60 104 F stop measuring The The thermometer has malfunctioned Please contact distributor Indicates a low battery condition Replace with 2 new AAA batteries as soon as possible Message Instruction Replace with 2 new AAA batteries immediately The temperature measured was higher than the specified mea suring range Wait 2 minutes and try again ...

Страница 13: ......

Отзывы: