OILTESTER - Deep-frying Oil Tester
Instruction manual
Страница 1: ...OILTESTER Deep frying Oil Tester Instruction manual...
Страница 2: ...2...
Страница 3: ...plays 14 5 2 2 1 Alarm indicator 14 5 2 2 2 Setting the TPM limit values 14 5 2 2 3 Hold function 15 5 2 2 4 Auto Hold function 15 5 2 2 5 Auto off function 15 5 2 2 6 Battery capacity 16 5 2 3 Config...
Страница 4: ...n on to any subsequent users of the product Warnings Always pay attention to information that is marked by the following warnings with warning pictograms Implement the specified precautionary measures...
Страница 5: ...nd feed lines to any temperatures in excess of 70 C unless they are expressly permitted for higher temperatures Do not perform contact measurements on non insulated live parts Transport and store the...
Страница 6: ...and determines the total amount of polar materials in as the reading The free fatty acids that are determined above all for the evaluation of unloaded oils rancidity cannot be detected The temperature...
Страница 7: ...measurements without display illumination Temperature sensor PTC TPM sensor Capacitive sensor Operating temperature 0 to 50 C 32 to 122 F Ambient humidity 0 to 90 RH Storage transport temperature 20 t...
Страница 8: ...Product description 8 4 Product description 4 1 Overview 1 Display 2 Control keys 3 Battery compartment 4 Probe shaft 5 Oil quality TPM and temperature sensor 6 Min immersion depth 7 Max immersion dep...
Страница 9: ...capacity 100 Battery capacity 66 Battery capacity 33 Battery capacity 10 Alarm Upper TPM limit value exceeded Alarm Lower TPM limit value exceeded Hold Readings held manually Auto Hold Readings held a...
Страница 10: ...d measuring values manually Switch to the measuring mode Configure instrument on off yes no Configure instrument on off yes no Configure instrument Battery compartment 4 2 Basic properties Power suppl...
Страница 11: ...s 5 1 Commissioning Inserting batteries CAUTION Incorrectly inserted batteries can damage the instrument Adhere to the polarity when inserting the batteries 1 Undo the screw on the battery compartment...
Страница 12: ...to the battery compartment 5 Secure battery compartment with screw 6 Switch instrument on Press Display test is carried out all segments light up The instrument switches to the measuring mode 000 ligh...
Страница 13: ...case for protection against contamination and for transport 5 2 Getting to know the product 5 2 1 Switching the instrument on off To switch on Press until the indicator elements appear in the display...
Страница 14: ...PM limit values see Setting the TPM limit values page 14 5 2 2 2 Setting the TPM limit values The TPM limit values can be between 0 and 40 The upper limit value Alarm must be at least 1 higher than th...
Страница 15: ...appears in the display Readings are held 2 To switch to the measuring mode Briefly press Hold 1 sec Hold function is deactivated Current readings are displayed 5 2 2 4 Auto Hold function When the Auto...
Страница 16: ...AL no Do not carry out calibration yes Carry out calibration Automatically hold readings Auto Hold on Readings are automatically held by the instrument off Readings are not automatically held Automati...
Страница 17: ...ights up in the display Set lower limit value Alarm or and confirm with Hold Alarm lights up in the display Set upper limit value Alarm or and confirm with Hold 3 Carry out do not carry out calibratio...
Страница 18: ...y and saving You can quit the configuration mode early The configuration mode cannot be stopped in the adjustment calibration process Quit configuration mode early Press and hold for approx 1 sec Conf...
Страница 19: ...Select first figure or and confirm with Hold Select second figure or and confirm with Hold If an incorrect PIN is entered the instrument switches into measuring mode The configuration mode is enabled...
Страница 20: ...d deviations may occur Comparison of laboratory methods OILTESTER Cooking oil is a mixture of substances with a wide variety of polarities During ageing the proportion of more highly polar components...
Страница 21: ...ts of this method are in most cases comparable with the TPM value PTG TPM 2 6 2 Carrying out measurements WARNING Risk of burns due to hot instrument parts sensor and probe shaft Do not touch hot inst...
Страница 22: ...value the cooking oil should be changed With activated Auto Hold function 1 Immerse the sensor in cooking oil Adhere to the immersion depth If the temperature is within the permissible measuring rang...
Страница 23: ...150 to 180 C We recommend performing the function test every time after refilling the deep fryer with fresh oil 1 Perform measurement in unused deep frying oil at 150 to 180 C see Carrying out measure...
Страница 24: ...sensor WARNING Risk of burns due to hot instrument parts sensor and probe shaft Do not touch hot instrument parts with your hands Allow instrument to cool sufficiently before cleaning In the event of...
Страница 25: ...eaning the plastic case CAUTION Possible damage on and in the plastic case Do not use sharp edged objects Do not use any aggressive cleaning agents or solvents Use mild household cleaning agents stand...
Страница 26: ...Battery charge level low approx 2 5 hrs remaining life Change batteries if necessary Battery symbol flashes Batteries empty approx 1 2 hrs remaining life Change batteries 000 lights up Sensor not in o...
Страница 27: ...adjustment value a TPM value discrepancy of more than 10 TPM occurs We recommend a technical check of the instrument by Vito AG If we have not been able to answer your question please contact your lo...
Страница 28: ...0970 2752 en 01 V01 00 Vito AG Eltastrasse 6 D 78532 Tuttlingen Fon 0800 3050777 Fon 49 0 7461 96289 0 Fax 49 0 7461 96289 12 info vito ag www vito ag...