TM-RX Receiver
May 2021
Visual Engineering
Video solutions. Integrated
visualengineering.co.uk
Page 29
Maintainer Guide
Activating the Web Interface
The following web browser control interface is not required for normal operation. Web browser
control of the Mesh radio should only be undertaken by users wishing to achieve the following:
• Switch the operating mode of the radio
• Change the system frequency
• Change the system IP addresses
• Change the Encryption key
• Understand the RF performance of the system better
Maintainers should be very careful when using this interface because it is
entirely possible to make changes that will leave the system inoperable,
requiring the system to be returned to base for repair.
Power up the TM-RX and connect its configuration cable to the EXT-A connector. Then connect the
RJ45 connector to a PC.
• Open a web browser on the PC
• Type the IP address of the unit e.g.
192.168.1.180
into the address bar
• The web browser opens a
Login Prompt
Login Prompt
• Authentication is required to connect
• By default there is no user name
• By default the Password is
Eastwood
• Click the Connect button
To find IP address of radio in the TM-RX refer to the
settings page.
Mesh Radio Configuration
This section is intended for the Maintainer to setup the network and radios using a web browser
control interface.