
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
49
the Monitoring Station indicating that the alarm was canceled by the user. Here you can
activate the feature and select the "Cancel Alarm" time period.
Previously known as
"ALARM CANCEL"
Option settings:
not active
(default in USA);
in 1 minute
,
in 5 minutes
(default);
in 15
minutes
;
in 60 minutes
and
in 4
hours
.
Note:
To comply with
CP-01
requirements, "1 minute" option must not be used.
Previously known as
"RESET OPTIONS"
Certain regulations (such as in the UK) require that following an alarm event the system
cannot be rearmed before it is checked and reset by an installer (engineer). To answer
this requirement, the PowerMaster-10 provides you with the following configurable
options for resetting the alarm event and rearming the system:
A:
By the user as usual (
by user)
.
B:
By the engineer (installer) by entering and exiting the "Installer Mode" or by accessing
the system remotely via the telephone using the Installer Code (
by engineer
). For
accessing the system via the telephone, see the User's Guide, Chapter 5 – "Remote
Control by Telephone" and use installer code instead of user code.
Option settings:
by user
(default) and
by engineer
.
Note:
This feature is not applicable in the USA.
3.5.5 Configuring Sirens Functionality
The following table provides you with a detailed description of each option and its configuration settings. To
select an option and change its configuration – refer to section 3.5.1.
Option
Configuration Instructions
Previously known as
"PIEZO SIREN"
Determine whether the internal siren of the control panel will sound alarms (ON) or
remain silent (OFF).
Option settings:
ON
(default) and
OFF
.
Previously known as
"BELL TIME"
Here you can define the operating time the sirens will sound upon alarm. Once the
"Siren Time" expires or the system is disarmed, the siren automatically shuts down.
Option settings:
1 minute
;
3 minutes
;
4 minutes
(default)
; 8 minutes
;
10 minutes
;
15
minutes
and
20 minutes
Note:
To comply with
EN
requirements, the "Siren Time" must not exceed 15 minutes.
Here you can define the length of time the strobe light will flash upon alarm.
Option settings:
5 minutes
;
10 minutes
,
20 minutes
(default);
40 minutes
and
60
minutes
Determine whether the siren will be activated or not when the telephone line fails when
the system is armed.
Option settings:
disable on fail
(default) or
enable on fail
.
3.5.6 Configuring Audible & Visual User Interface
The following table provides you with a detailed description of each option and its configuration settings. To
select an option and change its configuration – refer to section 3.5.1.
46
:SIREN
ON
LINE
44:SIREN TIME
43:PANEL SIREN
45:STROBE TIME
39:ALARM RESET