38
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
02
Exit / Entry 2
Same as Exit / Entry 1 but allows to define a different entry delay. Used sometimes
for entrances closer to the panel. For configuring the Exit and Entry 2 delays, see
sections 3.5.1 & 3.5.2 - Installer menu
options 02 and 03.
(
∗
)
03
Home Delay
Used for Door/Window Contacts and Motion sensors protecting entrance doors to
interior living areas where you wish to move feely when the system is armed HOME.
Functions as a "Delayed" zone when the system is armed HOME and as a
"Perimeter Follower" zone when the system is armed AWAY.
04
Interior-Follower
Used for Door/Window Contacts and Motion sensors protecting the route between
the entrance door and the control panel. This zone is temporarily ignored by the
alarm system during entry/exit delay periods, otherwise provides instant alarm. (
∗
)
05
Interior
Used for Door/Window Contacts, Motion and glass-break sensors installed in interior
areas that need to be protected only when the system is armed AWAY but not
protected when the system is armed HOME. When tripped provides instant alarm.
06
Perimeter
Used for all type of sensors protecting the perimeter of the premises when the
system is armed both AWAY and HOME. When tripped provides instant alarm.
07
Perimeter -
Follower
Used for all type of sensors protecting the perimeter of the premises but temporarily
ignored by the alarm system during entry/exit delay periods, otherwise provides
instant alarm.
(
∗
)
08
24hr Silent
Used to report alarm events from sensors (or manually activated buttons) to the
monitoring station or private telephones (as programmed) without activating the
sirens. Active 24 hours.
09
24hr Audible
Used to report alarm events from sensors (or manually activated button) to the
monitoring stations or private telephones (as programmed) and also providing an
audible siren alarm. Active 24 hours.
10
Emergency
Used for pendants and other emergency sensors and activators to initiate an
Emergency call
to the monitoring stations or private telephones (as programmed).
11
Arming Key
An Arming key is a zone that can be used for arming and disarming the system by a
wired PowerG detector or by a magnetic contact PowerG device that is enrolled to a
zone. In addition, the alarm system may be armed / disarmed by a keyswitch when
connected to wired zones.
12
Non-Alarm
Used for non-alarm applications. For instance sensors or activators used for Chime
only, remote control, home automation etc. Not valid for PIR cameras.
17
Guard Key box
A Guard Key zone is a 24H Zone. Since the Guard Key box is a hardwired unit, the
installation is done with a wired PowerG detector that is located inside the wall,
where the Guard Key box is installed.
(
∗
)
These Zone Types are useful mainly when you arm and disarm the system from inside the protected
premises. If you arm and disarm the system from outside (without tripping any sensor), such as using a
keyfob, it is preferred to use the other Zone Types.
03.CONTROL PANEL