background image

D-303360 CLIP SMA Installer's Guide 

 

CLIP SMA

 

Wireless Curtain-Type Infrared Detector 

 

Installation Instructions

 

1. INTRODUCTION 

The CLIP SMA is the smallest and most elegant wireless curtain-

pattern PIR detector for indoor use and designed for easy 

installation. Its function is based on new and sophisticated, 

patented FM data acquisition and digital signal processing.  
Modern technology is used to include 3 different detectors in a 

single case, each programmable for optimized performance at 

the specific mounting location. This results in better catch 

performance and virtually no false alarms. 
The superiority in performance of this detector is achieved by 

applying an improved version of the patented 

True Motion 

Recognition™

 (TMR) algorithm. This advanced motion analysis 

method allows the CLIP SMA to distinguish between the true 

motion of the human body and any other disturbances that cause 

false alarms.  

After detection, the detector disarms itself to save battery power. 

It rearms (reverts to the ready state) if there is no subsequent 

detection throughout the following 2-minute period. 
The CLIP SMA includes the following features: 

  Very low current consumption 

  Microprocessor-controlled temperature compensation 

  Sealed chamber protects the optical system 

  Front cover tamper switch 

  White light protection 

  Elegantly styled, sturdy case 

Detailed coverage patterns and mounting alternatives are 

illustrated in Figures 2 through 6. 

 

Figure 1.

 CLIP SMA General View 

 

Figure

 

2.

 Wall-Mount Curtain

 

2.4m

 

Figure 3.

 Ceiling-Mount Curtain

 

 

Figure 4.

 Overhead Curtain

 

This

side

up

  

Figure 5.

 Curtain / Pet Alley

 

OPTION A

OPTION B

DETECTION

CURTAIN

 

Figure 6.

 CLIP SMA on Internal Doorframe

 

 

2. SPECIFICATIONS 

OPTICAL

 

Detector Type: 

Dual-element low noise pyroelectric sensor.

 

Number of Curtain Beams:

 2

 

Mounting Positions:

 See Figures 2 through 6. 

Range Settings:

 Long (6 m/18 ft), Medium (4 m/12 ft) and Short (1.2 - 

2m/6 ft) (Jumper-selected).  

ELECTRICAL 
Internal Battery:

 3V Lithium battery, type CR123A. For UL installations, 

use Panasonic, GP or Sanyo only. 

Nominal Battery Capacity:

 1450 mAh. 

Battery Life: 

3 years (for typical use). 

Note

: Inability to connect with wireless network, or wireless link quality no 

higher than 20% may significantly reduce the expected battery life. 

Battery Power Test: 

Performed immediately upon battery insertion 

and periodically every several hours.

 

Microprocessor: 

8-bit, low power CMOS. 

FUNCTIONAL 
Visual Indications (red LED):  

 

LED lights 

for about 3 seconds upon transmission of alarm & tamper 

messages and upon motion detection in the walk test mode. 

 

 

LED flashes

 during the power-up stabilization period (approx. 2 

min), or after restoring the cover (by pressing the tamper switch). 

 

LED does not light 

upon transmission of supervision messages. 

Alarm Period:

 Approx. 3 seconds. 

Rearm Timer:

 Rearms the detector 2 minutes after the last alarm.  

WIRELESS 
Frequency: 

2.4 Ghz as per IEEE 802.15.4 

 

Tamper Alert:

 Reported when a tamper event occurs and in any 

subsequent message, until the tamper switch is restored. 

Supervision Message: 

Signaling at 24-minute intervals. 

MOUNTING

  

Height:

 1.8 - 2.4 m (6 - 8 ft). See Figures 2 – 6. 

Installation Options:

 See Figures 2 – 6. 

ENVIRONMENTAL

  

Operating Temperature:

 -10°C to 50°C (14°F to 122°F).  

Storage Temperature:

 -20°C to 60°C (-4°F to 140°F).  

RFI Protection:

 > 20 V/m to 1000 MHz.  

Compliance with standards:

  

USA: CFR 47 part 15, Canada: RSS 210

ANSI/UL 639, ULC – S306 

PHYSICAL

  

Dimensions (H x W x D):

 105 x 35 x 30 mm (4-1/8 x 1-3/8 x  

1-3/16 in.).  

Weight (with battery): 

60 g (2.1 oz).  

Color:

 White. 

PATENTS 

U.S. Patent 5,693,943 (other patents pending) 

Содержание CLIP SMA

Страница 1: ...rnal Doorframe 2 SPECIFICATIONS OPTICAL Detector Type Dual element low noise pyroelectric sensor Number of Curtain Beams 2 Mounting Positions See Figures 2 through 6 Range Settings Long 6 m 18 ft Medi...

Страница 2: ...View BREAK AWAY SEGMENT ATTENTION The back tamper switch becomes functional only when the break away segment is secured to the wall with a scre w MOUNTING SURFACE INSERT SCREW TO SECURE COVER WITH BA...

Страница 3: ...N THE MOUNTING SURFACE 1 SECURE BRACKET WITH TWO SCREWS 2 Figure 10 Mounting Bracket to Surface PLACE THE LOCKING PLATE OVER THE TWO PINS 2 SECURE THE LOCKING PLATE BY PRESSING DOWNWARD 3 LOCKING PLAT...

Страница 4: ...nd tighten the screw Wait for the detector to stabilize the LED stops flashing approx two minutes after the cover is closed B Walk slowly across the far end of the curtain pattern in opposite directio...

Страница 5: ...e complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interferen...

Страница 6: ...the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or con...

Страница 7: ...cover is removed a tamper message is transmitted to the receiver Subsequent removal of the battery prevents transmission of TAMPER RESTORE leaving the receiver in permanent alert To avoid this during...

Страница 8: ...scribed in the control panel installation manual Make sure that the signal is sufficient If necessary replace the sensor s battery The sensor sends a Low Battery indication To ensure continuous proper...

Страница 9: ...ter 30 min or if the detector goes into alarm restore After 30 minutes an alarm bit will be sent as part of the supervision message ELECTRICAL DATA Power Source 3 Volt CR123A CR17450 lithium Panasonic...

Страница 10: ...amper switch Transmission LED ON OFF button Figure 3b Battery Connection for CR17450 Note When the battery first makes contact the alarm horn may sound for one second This indicates that the battery i...

Страница 11: ...gure 7 Placing Smoke Detectors in a Multi Floor Residence Install basement detectors at the bottom of the basement stairwell Install second floor detectors at the top of the first to second floor stai...

Страница 12: ...ion smoke from fires in chimneys in walls on roofs in remote parts of the building or on another level from where the smoke detector is located may not reach the smoke detector quickly enough for occu...

Страница 13: ...y s protection from fires A Install smoke detectors properly Carefully follow all the instructions in this manual Keep your smoke detectors clean and test them every week B Remember that detectors tha...

Страница 14: ...NESS FOR A PARTICULAR PURPOSE OR OTHERWISE IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOE...

Страница 15: ...Active Life 5 years Selectable Sensitivity DIP switch in EN Mode No warning at 30 ppm for 120 minutes 50 ppm for 60 minutes 100 ppm for 10 minutes Warning at 50 ppm between 60 90 minutes 100 ppm for 1...

Страница 16: ...ntain a CO detector may cause it to fail resulting in loss of life Installation of the CO detector should not be used as a substitute for proper installation use and maintenance of fuel burning applia...

Страница 17: ...s produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Visonic Ltd M N E...

Страница 18: ...cise The time of onset of exercise induced angina pectoris in such patients exposed to low levels of CO is reduced Carbon monoxide readily crosses the placental barrier and may endanger the normal dev...

Страница 19: ...urnaces or water heaters e Obstructions in or unconventional vent pipe designs which amplify the above situations 2 Extended operation of unvented fuel burning devices range oven fireplace etc 3 Tempe...

Страница 20: ...ed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply under certain circumstances The Manufacturer shall be under...

Страница 21: ...reduce the expected battery life Battery Supervision Automatic reporting of battery condition data as part of any transmission ALARM REPORT Every 20 sec for the first 3 minutes Every 3 min for the ne...

Страница 22: ...NTING SCREWS Fig 6 Base with P C Board Removed FUNCTIONSELEC TOR TRANSMITTER RF MODULE TAMPERSWITCH AUX INPU T TERMINALS 3 V LITHIUMBATTERY LED FLEXIBLERETAINER P C BOARDSUPPO RTS WIRESTO FLOOD SENSOR...

Страница 23: ...r learn the ID code associated with the detector 4 5 Maintenance To ensure proper detector s operation clean the flood sensor thoroughly with a rag once a month and perform test 5 TROUBLESHOOTING If y...

Страница 24: ...DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED...

Страница 25: ...mAh Battery Life with LED on Typically over 3 years Note Inability to connect with wireless network or wireless link quality no higher than 20 may significantly reduce the expected battery life Batter...

Страница 26: ...Detector To pair the detector to the control panel you must set it to pairing mode 1 Press and hold down the detector s tamper switch 2 Insert the battery into the detector 3 Release the tamper switc...

Страница 27: ...occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or mo...

Страница 28: ...sive remedy against the Manufacturer When accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdic...

Отзывы: