2
D-303361 NEXT® PLUS K9-85 SMA Installation Instructions
3.2 Installation Procedure
1. For battery installation, see steps 1-3 below.
2. For mounting the detector, see step 4 below.
1
2
Push catch and remove board
On surface
In corner
4
Mounting
3
Insert battery
Front Tamper switch
Release screw and
remove cover
Fig. 3 – Battery Installation and Mounting
Note
: The detector transmits a low battery signal upon detection of
low voltage. It is recommended to wait about 1 minute after battery
removal, before inserting the new battery.
3.3 Activating the Detector
To activate, pull the strip that protrudes from the back of the detector.
Then, close the opening by pasting the supplied sticker over it.
Fig. 3a – Activation Strip
3.3 Pairing the Detector
To pair the detector to the control panel, you must set it to pairing
mode.
1.
Press and hold down the detector’s tamper switch.
2.
Insert the battery into the detector.
3.
Release the tamper switch and press it again within 4 seconds.
4.
Complete the pairing procedure on the control panel (see the pairing
instructions in the control panel’s installation guide).
3.4 Jumper Settings
2 events
- Highest false alarm protection
1 event -
fast response
ON - LED enabled
OFF - LED disabled
Fig. 4 - Jumper Settings
3.5 Walk Testing
Walk across the far end of coverage pattern in both directions.
The LED should light for 2-3 seconds each time your motion is
detected.
Important!
Instruct the user to walk test at least once a week to
verify proper function of the detector.
5
10
15 m
0
2.1 m
(6.9 ft)
16.4
32.8
49.2 ft
90°
5
0
16.4
0
15 m
49.2 ft
10
32.8
5m
16.4ft
5m
16.4ft
10m
32.8ft
10m
32.8ft
Top view
Side view
Fig. 5 - Coverage Pattern Walk-Test