background image

2

 

D-303364 MCT-427 SMA Installation Guide

 

Condition

 

Visual Indication (LEDs)

 

Audio 

Indication 

Red

 

Yellow

 

Heat sensor 

trouble

 

Flash every 60 

sec.

 

5 Flashes every 

60 sec.

 

Short beep every 

60 sec. 

Need to clean

 

2 flashes every 

30 sec.

 

-

 

2 short beeps 

every 30 sec. 

Test

 

See par. 3.6 

The tamper alarm will mute for 3 minutes at first power on, and 

will revert to normal mode when the tamper switch condition is 

changed. 

**  Delay of 15 sec. between buzzer beep and LED operation 

3.3 Battery Connection and Initial Test 

Caution!

 Risk of explosion if battery is replaced by an incorrect type. 

Dispose of used batteries according to the manufacturer's instructions. 

Attention: 

The detector battery cover is fitted with a red button that 

prevents the detector from locking onto bracket if there is no battery 

inside.  

The smoke detector is supplied with a 3V CR123A / CR17450 battery. 

Battery connection for both types of batteries is illustrated in Figure 3a 

and 3b below. 

Battery cover

Open battery cover and

connect the battery to its

t e r m i n a l s   ( w i t h o u t

insulator). Verify proper

polarity.

3 volts CR123A

Tamper

switch

Transmission

LED ON/OFF

button

 

Figure 3a.

 

Battery Connection for CR123A 

 

Battery cover

Open battery cover and connect the battery to its terminals.

3 volts CR17450

Tamper

switch

Transmission

LED ON/OFF

button

 

Figure 3b.

 

Battery Connection for CR17450

 

Note:

 When the battery first makes contact, the alarm horn may 

sound for one second. This indicates that the battery is connected 

properly.  

Close the cover, then press the test button (see fig. 1) for about 5 

seconds, (for further details see par. 3.6) 
.

3.4 Pairing/Defaulting the Detector 

Note:

 It is much easier to carry out this operation while holding the 

MCT-427 in your hand, close to the control panel.

 

To pair the detector to the control panel, you must set it to pairing 

mode. 

A. 

Press and hold down the detector’s tamper switch. 

B. 

Insert the battery into the detector. Wait for the RF 

module’s green LED to light. 

C. 

Release the tamper switch within 4 seconds and press it 

again. When the detector is in pairing mode, the green 
LED starts to blink. 

D. 

Complete the pairing procedure on the control panel (see 

the pairing instructions in the control panel’s installation 
guide). 

3.5 Mounting  

1

Mark and drill 2 holes in

the mounting surface.

Fasten the bracket to the

mounting surface with 2 screws.

2

Align bracket tabs with the

detector slots and rotate the detector

as shown. Pull the detector outward to

verify that it is securely attached.

BRACKET

DETECTOR

tab

(1 of 3)

 

Figure 4. 

Mounting the Detector 

Notes 

1. A battery must be inserted into the detector 

before the detector can be mounted onto the 

bracket. 

2. 

Unauthorized removal of the unit from the bracket 

will initiate a tamper alert!

 

Содержание CLIP SMA

Страница 1: ...rnal Doorframe 2 SPECIFICATIONS OPTICAL Detector Type Dual element low noise pyroelectric sensor Number of Curtain Beams 2 Mounting Positions See Figures 2 through 6 Range Settings Long 6 m 18 ft Medi...

Страница 2: ...View BREAK AWAY SEGMENT ATTENTION The back tamper switch becomes functional only when the break away segment is secured to the wall with a scre w MOUNTING SURFACE INSERT SCREW TO SECURE COVER WITH BA...

Страница 3: ...N THE MOUNTING SURFACE 1 SECURE BRACKET WITH TWO SCREWS 2 Figure 10 Mounting Bracket to Surface PLACE THE LOCKING PLATE OVER THE TWO PINS 2 SECURE THE LOCKING PLATE BY PRESSING DOWNWARD 3 LOCKING PLAT...

Страница 4: ...nd tighten the screw Wait for the detector to stabilize the LED stops flashing approx two minutes after the cover is closed B Walk slowly across the far end of the curtain pattern in opposite directio...

Страница 5: ...e complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interferen...

Страница 6: ...the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or con...

Страница 7: ...cover is removed a tamper message is transmitted to the receiver Subsequent removal of the battery prevents transmission of TAMPER RESTORE leaving the receiver in permanent alert To avoid this during...

Страница 8: ...scribed in the control panel installation manual Make sure that the signal is sufficient If necessary replace the sensor s battery The sensor sends a Low Battery indication To ensure continuous proper...

Страница 9: ...ter 30 min or if the detector goes into alarm restore After 30 minutes an alarm bit will be sent as part of the supervision message ELECTRICAL DATA Power Source 3 Volt CR123A CR17450 lithium Panasonic...

Страница 10: ...amper switch Transmission LED ON OFF button Figure 3b Battery Connection for CR17450 Note When the battery first makes contact the alarm horn may sound for one second This indicates that the battery i...

Страница 11: ...gure 7 Placing Smoke Detectors in a Multi Floor Residence Install basement detectors at the bottom of the basement stairwell Install second floor detectors at the top of the first to second floor stai...

Страница 12: ...ion smoke from fires in chimneys in walls on roofs in remote parts of the building or on another level from where the smoke detector is located may not reach the smoke detector quickly enough for occu...

Страница 13: ...y s protection from fires A Install smoke detectors properly Carefully follow all the instructions in this manual Keep your smoke detectors clean and test them every week B Remember that detectors tha...

Страница 14: ...NESS FOR A PARTICULAR PURPOSE OR OTHERWISE IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOE...

Страница 15: ...Active Life 5 years Selectable Sensitivity DIP switch in EN Mode No warning at 30 ppm for 120 minutes 50 ppm for 60 minutes 100 ppm for 10 minutes Warning at 50 ppm between 60 90 minutes 100 ppm for 1...

Страница 16: ...ntain a CO detector may cause it to fail resulting in loss of life Installation of the CO detector should not be used as a substitute for proper installation use and maintenance of fuel burning applia...

Страница 17: ...s produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Visonic Ltd M N E...

Страница 18: ...cise The time of onset of exercise induced angina pectoris in such patients exposed to low levels of CO is reduced Carbon monoxide readily crosses the placental barrier and may endanger the normal dev...

Страница 19: ...urnaces or water heaters e Obstructions in or unconventional vent pipe designs which amplify the above situations 2 Extended operation of unvented fuel burning devices range oven fireplace etc 3 Tempe...

Страница 20: ...ed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply under certain circumstances The Manufacturer shall be under...

Страница 21: ...reduce the expected battery life Battery Supervision Automatic reporting of battery condition data as part of any transmission ALARM REPORT Every 20 sec for the first 3 minutes Every 3 min for the ne...

Страница 22: ...NTING SCREWS Fig 6 Base with P C Board Removed FUNCTIONSELEC TOR TRANSMITTER RF MODULE TAMPERSWITCH AUX INPU T TERMINALS 3 V LITHIUMBATTERY LED FLEXIBLERETAINER P C BOARDSUPPO RTS WIRESTO FLOOD SENSOR...

Страница 23: ...r learn the ID code associated with the detector 4 5 Maintenance To ensure proper detector s operation clean the flood sensor thoroughly with a rag once a month and perform test 5 TROUBLESHOOTING If y...

Страница 24: ...DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED...

Страница 25: ...mAh Battery Life with LED on Typically over 3 years Note Inability to connect with wireless network or wireless link quality no higher than 20 may significantly reduce the expected battery life Batter...

Страница 26: ...Detector To pair the detector to the control panel you must set it to pairing mode 1 Press and hold down the detector s tamper switch 2 Insert the battery into the detector 3 Release the tamper switc...

Страница 27: ...occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or mo...

Страница 28: ...sive remedy against the Manufacturer When accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdic...

Отзывы: