manualshive.com logo in svg
background image

ENGINEERING

GUIDES

Date of last revision: 2.06

TREADMILL.UPPERBDENG.DELUXE.REV1

3

T9500/T9600 VARIABLES

Address

Description

Default Value

Min.Value

MaxValue

P0

Minimum Speed Data

N/A

310

600

SP1

Speed Data 2

N/A

700

1400

P1

1/2 max Speed Data

N/A

2000

3200

SP2

Speed Data 4

N/A

3000

4200

P2

Max speed Data

N/A

3900

5200

P3

LED Brightness

3

0

9

P4

Minimum  Elevation Data

250

30

300

P5 

Max Elevation Data

850

650

900

P6

Model and Unit (Metric/US)

N/A

N/A

N/A

P7

Max Time

99

15

99

P8

Default Weight

150

80

400

P9

Accumulated Time

N/A

N/A

N/A

P10

Accumulated Distance

N/A

N/A

N/A

P11

Belt Thickness (depending on model)

16

44

P12

Roller Diameter

60

60

60

P13

Elevation motor

1

N/A

N/A

P14

Pause Time

5:00

:20

10:00

P15

Default Time

30

1

99

P16

Default Age

40

5

120

P17

Exit Mode (Exits Eng 1)

CONFIGURATIONS

Modify the units by pressing the speed arrows to select MI or KM. Modify the model by pressing the elevation arrows.
Press and hold 

“SELECT”

to save.

Deluxe Upper Board: Engineering Guide 

T9250 

0-12% elevation
0.5-10 mph/ 0.8-16kph

T9450

0-12% elevation
0.5-10 mph/ 0.8-16kph

T9200

0-12% elevation
0.5-10 mph/ 0.8-16kph

T9500

0-12% elevation
0.5-12 mph/ 0.8-20 kph

T9600

0-15% elevation
0.5-12 mph/ 0.8-20 kph

Содержание T9200 DELUXE

Страница 1: ...IDES 1 Date of last revision 2 06 TREADMILL UPPERBDENG DELUXE REV1 S T A N D A R D C O N S O L E F O R T9200 DELUXE T9500 DELUXE T9600 DELUXE T9250 DELUXE T9450 DELUXE DELUXE 6 WINDOW UPPER BOARD ENGI...

Страница 2: ...In Mode Runs continuous program Eng 4 Auto Calibration Mode Calibrates both speed and elevation Eng 5 Speed Sensor Test Tests speed sensor functionality Eng 6 Exit Exit engineering mode ENG1 EDIT VAR...

Страница 3: ...0 80 400 P9 Accumulated Time N A N A N A P10 Accumulated Distance N A N A N A P11 Belt Thickness depending on model 16 44 P12 Roller Diameter 60 60 60 P13 Elevation motor 1 N A N A P14 Pause Time 5 00...

Страница 4: ...start is at half max The user can adjust the speed and incline The program returns to the preset incline upon segment completion Keyboard functions are the same as in normal operating mode ENG 4 AUTO...

Страница 5: ...er is still being applied to the board This safety switch condition occurs in any mode including engineering modes When the magnet reconnects to the console the board resets Any activity or run time i...

Страница 6: ...red user programs Changing units may also require you to perform auto calibration MAX TIME P7 represents the maximum time which is displayed in the upper right window This is the maximum amount of tim...

Страница 7: ...ing To begin auto calibration press START The treadmill will run through minimum and maximum speed and maximum incline this will take three to five minutes Let the treadmill perform this complete func...

Отзывы: