manualshive.com logo in svg
background image

ENGINEERING

GUIDES

Date of last revision: 2.06

TREADMILL.UPPERBDENG.DELUXE.REV1

2

ENGINEERING MODE

The user must hold down 

“ELEVATION UP”

and 

“SPEED DOWN”

for 5 seconds after powering up the treadmill to

enter the engineering menus. The P6 menu appears with the software version in the upper right window along with
the model number in the upper left window. Press 

“STOP”

to exit P6. The user has 6 engineering modes to choose

from. The 

“SPEED”

and 

“ELEVATION”

keys scroll through the modes, while 

“SELECT”

chooses the mode. HOLDING

the 

“SELECT”

button saves information and the 

“STOP”

button goes back to the previous screen. When in

Engineering modes 1-5, holding down the 

“STOP”

button for 5 seconds will return you to the Engineering Mode

Selection Screen.

Display

Engineering Mode

Eng 1- Configure Mode

Edits variables stored in the NOVRAM. Speed and Incline variables 
can be edited in this mode.

Eng 2- Display and Key Test

Tests displays and keyboard

Eng 3- Burn In Mode

Runs continuous program

Eng 4- Auto Calibration Mode

Calibrates both speed and elevation

Eng 5- Speed Sensor Test

Tests speed sensor functionality

Eng 6- Exit 

Exit engineering mode

ENG1: EDIT VARIABLES MODE

The display shows the P address. To choose the P address press 

“SELECT”

.

To clear P9 total time press and hold 

“START”

for 3 seconds

To clear P10 total distance press and hold 

“START”

for 3 seconds

T9200/T9250/T9450 VARIABLES

Address

Description

Default Value

Min.Value

MaxValue

P0

Minimum Speed Data

N/A

310

600

SP1

Speed Data 2

N/A

700

1100

P1

1/2 max Speed Data

N/A

1400

2100

SP2

Speed Data 4

N/A

2000

3000

P2

Max speed Data

N/A

3200

4500

P3

LED Brightness

3

0

9

P4

Minimum  Elevation Data

N/A

30

300

P5 

Max Elevation Data

N/A

650

900

P6

Model and Unit (Metric/US)

N/A

N/A

N/A

P7

Max Time

99

15

99

P8

Default Weight

150

80

400

P9

Accumulated Time

N/A

N/A

N/A

P10

Accumulated Distance

N/A

N/A

N/A

P11

Belt Thickness (depending on model)

16

44

P12

Roller Diameter

60

60

60

P13

Elevation motor

1

P14

Pause Time

5:00

:20

10:00

P15

Default Time

30

1

99

P16

Default Age

40

5

120

P17

Exit Mode (Exits Eng 1)

Deluxe Upper Board: Engineering Guide 

Содержание T9200 DELUXE

Страница 1: ...IDES 1 Date of last revision 2 06 TREADMILL UPPERBDENG DELUXE REV1 S T A N D A R D C O N S O L E F O R T9200 DELUXE T9500 DELUXE T9600 DELUXE T9250 DELUXE T9450 DELUXE DELUXE 6 WINDOW UPPER BOARD ENGI...

Страница 2: ...In Mode Runs continuous program Eng 4 Auto Calibration Mode Calibrates both speed and elevation Eng 5 Speed Sensor Test Tests speed sensor functionality Eng 6 Exit Exit engineering mode ENG1 EDIT VAR...

Страница 3: ...0 80 400 P9 Accumulated Time N A N A N A P10 Accumulated Distance N A N A N A P11 Belt Thickness depending on model 16 44 P12 Roller Diameter 60 60 60 P13 Elevation motor 1 N A N A P14 Pause Time 5 00...

Страница 4: ...start is at half max The user can adjust the speed and incline The program returns to the preset incline upon segment completion Keyboard functions are the same as in normal operating mode ENG 4 AUTO...

Страница 5: ...er is still being applied to the board This safety switch condition occurs in any mode including engineering modes When the magnet reconnects to the console the board resets Any activity or run time i...

Страница 6: ...red user programs Changing units may also require you to perform auto calibration MAX TIME P7 represents the maximum time which is displayed in the upper right window This is the maximum amount of tim...

Страница 7: ...ing To begin auto calibration press START The treadmill will run through minimum and maximum speed and maximum incline this will take three to five minutes Let the treadmill perform this complete func...

Отзывы: