![Vision Fitness T9200 DELUXE Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/vision-fitness/t9200-deluxe/t9200-deluxe_engineering-manual_1031975007.webp)
ENGINEERING
GUIDES
Date of last revision: 2.06
TREADMILL.UPPERBDENG.DELUXE.REV1
7
DEFAULT AGE
P16 represents the default age, which is displayed in the upper left window. The Treadmill comes with the default age
of 40. You can modify the age by using the
“SPEED”
or
“ELEVATION”
arrows. Press and hold
“SELECT”
to save
the new value.
AUTO-CALIBRATION
DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION!
Auto-calibration is not represented by a Px designation.
""AAUUTTOO""
appears in the center window. When you enter the
function,
""AAUUTTOO""
begins flashing. To begin auto-calibration, press
“START”
. The treadmill will run through minimum and
maximum speed and maximum incline, this will take three to five minutes. Let the treadmill perform this complete function
before exiting the Engineering Mode.
Elevation A/D or Elevation in % appears in the left window. PWM value or Speed appears in the right window.
""EE
""
will appear in the center window when the auto-calibration is complete. When auto-calibration is complete, it
will take about 30 seconds to return to the start-up screen with
““PP11””
showing in the function window.
EXIT USER ENGINEERING MODE
P17 represents exit mode. When you press
“SELECT”
to select the function, the console performs a reboot, returning
to program setup.
Deluxe Upper Board: Engineering Guide