Vpod Instruction Manual 

 

inside the battery compartment.   

 

Fig. 3 

Cautions! 

  Be sure to install batteries with correct polarities. 

  Only use the approved batteries. 

  Do not use batteries not specified for this unit.   

  Do not dispose of batteries in fire. 

  If battery fluid gets on your skin or clothing, rinse with plenty of clean water immediately. 

  Remove  the  batteries  from  this  unit  when  you  are  not  going  to  use  it  for  a  long  period  of  time 

(approximately one month). 

  Do not use batteries of a different type together. 

  Do not use new and used batteries together. 

  Dispose of batteries in accordance with the local ordinances and regulations. 

2.3 Connect the sensor 

Connect the oximeter sensor to the top of the oximeter as shown in Fig. 4. Ensure that the sensor is 
firmly plugged in. 

 

Fig. 4 

 
Notice:   

The connector is also applied to upload data to Virtuox software for managing data.   

 
CHAPTER 3 Setup before Operation   
3.1 Power on the oximeter 

Short press the Power button to power the oximeter on. 

Notice: 

  To  maintain  the  highest  degree  of  accuracy,  it  is  recommended  that  the  finger  and  the 

oximeter sensor/probe should be kept as still as possible. 

3.2 Enter “Setting mode”   

Press  the  function  button  for  about  4  second  (extended  press),  the  oximeter  will  enter  into  “Setting 

mode” and you will find a parameter item which include its title and value on the top right corner of the 

display (refer to Fig.5). 
After entering the setting mode from the normal screen, continually press Function button, the current 

parameter item will be changed sequentially in the following order: 
Br(brightness)  -->ID(patient’s  ID)  -->Y(year)  -->M(month)  -->D(date)  -->H(hour)  -->m(minute) 

-->S(second) --Br(brightness)-->... 

 

Fig.5 

Notice: 

When setting date and time, please don’t insert finger. 

b) Save and exit from “Setting mode” 

Under the “Setting mode”, press “function key (left key)” to select the desired parameter item.   

Then press “Setting key (right key)” to adjust the value. 

Each time when you press the “Setting key (right key)”, current parameter value will be added by 1 unit 

sequentially.   
Double press the “Setting key (right key)” and the current parameter setting will be added by 10 units 

sequentially. All use circular logic.

 

Press  “function  key  (left  key)”  to  select  the  next  desired  parameter  item.  Then  redo  step 

  to 

adjust  the  value.  You  can  continually  redo  step 

  to 

  until  no  parameter’s  setting  need  to  be 

changed. 

To finish setup, 

fleetly

 

press

 

both left and right keys

 

together

 

to confirm

. Then the modifications 

Содержание VPOD

Страница 1: ...s of data storage High Resolution Pulse Oximetry Records at 1 second intervals Three display modes Special design for sleep monitoring LCD Displays SpO2 SpO2 waveform Pulse Rate Low power consumption...

Страница 2: ...ights or patents and does not convey any license under the patent rights of our company nor the rights of others We do not assume any liability arising out of any infringements of patents or other rig...

Страница 3: ...nts Basis of Operation 1 Red and Infrared ray Emitter Diode 2 Red and Infrared ray Receptor Diode 1 2 Safety Information Conception of Warning Precaution and Notice Warning Indicates a potential hazar...

Страница 4: ...ry to use the SpO2 and NIBP measurement on the same arm at the same time This could potentially affect measurement accuracy Notices Operation of this device in an electromagnetic field may influence i...

Страница 5: ...of operation Continuous operation Equipment not suitable for use in the presence of a flammable anesthetic mixture air or with oxygen or nitrous oxide 1 6 Intended Use The purpose and function of the...

Страница 6: ...utton Note If no press on any button for 30 seconds the oximiter will power off automatically 4 The Setting button Press this button repeatedly to increase the parameter under adjustment by one decrem...

Страница 7: ...as still as possible 3 2 Enter Setting mode Press the function button for about 4 second extended press the oximeter will enter into Setting mode and you will find a parameter item which include its t...

Страница 8: ...h After turning on the oximeter each time the function button is pressed the oximeter will switch to another display mode shown as Fig 7 4 3 Factors that may affect the measurement During operation th...

Страница 9: ...gram measurement can also provide a plethysmogram wave During this mode the PR tone is dumb Fig 7 3 SpO2 plethysmogram wave PR tone modulation Beeps in sync with the patient s pulse even under most ch...

Страница 10: ...disinfecting 1 Clean or disinfect the sensor before each use 2 Unplug the sensor from the oximeter before cleaning and or disinfecting 3 Clean the external sensor surfaces and patient contact surface...

Страница 11: ...ted 2 The connection between the Probe and Oximeter is loose 1 Connect the sensor 2 Please check if the probe was connected with oximeter correctly 5 5 1 Service Method a Service hours 9 00am 5 30pm M...

Страница 12: ...he user s request Return Policy Warranty and non warranty returns should be handled in the following manner Contact the Technical Support Department and obtain a RMA Return Materials Authorization num...

Страница 13: ...Display Type OLED double color Parameters SpO2 PR SpO2 plethysmogram waveform PR bar Mode 3 display modes Record Patient ID 1 10 Data record Up to 72 hours Data transmission Transmission method Cable...

Страница 14: ...eclaration Electromagnetic Immunity for Equipment and Systems that are not Life Supporting 61000 4 6 Radiated RF IEC 61000 4 3 3V m 80Hz to 2 5 GHz d P V1 5 3 80MHz to 800MHz d P E1 5 3 800MHz to 2 5G...

Страница 15: ...minimum distance between portable and mobile RF communication equipment transmitters and the Handheld Pulse Oximeter as recommended below according to the maximum output power of the communications eq...

Страница 16: ...Vpod Instruction Manual 15...

Отзывы: