Vpod Instruction Manual 

 

11 

a) User must read user manual carefully before operation. 
b) User must operate and perform daily maintenance under manual specifications. 
c) Power supply and environment must be maintained under manual specifications. 

5.5.4 Circumstances that may void the warranty 

  The device does not remain in original condition. 

  The shell of the device is breached or cracked. 

  Evidence of water damage. 

  Accessories adulterated or appearance of physical abuse. 

  Evidence of crushing damage to the probe. 

  Original Packaging during transportation is not used.   

  Non authorized service is performed on oximeter. 

  Damage to a product as a result of not conforming to manual specifications. 

5.5.5 User’s Special Request for Extended Warranty 

Our warranty is consistent with industry standards.      The device and accessories come standard with 
a 1 year warranty.    An extended warranty can be purchased from Virtuox at the user’s request.   

Return Policy:   

Warranty and non warranty returns should be handled in the following manner:   
Contact the Technical Support Department and obtain a RMA (Return Materials Authorization) number. 
The RMA number must appear on the outside of the shipping container.   
Return shipments will not be accepted if the RMA number is not clearly visible.   
Please provide the model number, serial number (SN), and a brief description of the reason for return. 

Freight policy: 

 

 

 

 

1. Within Warranty: The customer is responsible for freight & insurance          charges when the 
equipment is shipped to Virtuox for service. Virtuox is responsible for the freight & insurance charges 
from us to the customer. 
2. After Warranty: The customer is responsible for any freight & insurance charges for returned 
product. 

5.5.6 Repackaging for returns

 

 

 

 

  Place all accessories in a watertight Ziploc bag 

  Use original package and packing material if possible. User will be responsible for damage caused 

by improper packaging during transportation. 

  Ensure the RMA number is clearly printed on the Box. 

  Include an insert describing the reason for the return. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание VPOD

Страница 1: ...s of data storage High Resolution Pulse Oximetry Records at 1 second intervals Three display modes Special design for sleep monitoring LCD Displays SpO2 SpO2 waveform Pulse Rate Low power consumption...

Страница 2: ...ights or patents and does not convey any license under the patent rights of our company nor the rights of others We do not assume any liability arising out of any infringements of patents or other rig...

Страница 3: ...nts Basis of Operation 1 Red and Infrared ray Emitter Diode 2 Red and Infrared ray Receptor Diode 1 2 Safety Information Conception of Warning Precaution and Notice Warning Indicates a potential hazar...

Страница 4: ...ry to use the SpO2 and NIBP measurement on the same arm at the same time This could potentially affect measurement accuracy Notices Operation of this device in an electromagnetic field may influence i...

Страница 5: ...of operation Continuous operation Equipment not suitable for use in the presence of a flammable anesthetic mixture air or with oxygen or nitrous oxide 1 6 Intended Use The purpose and function of the...

Страница 6: ...utton Note If no press on any button for 30 seconds the oximiter will power off automatically 4 The Setting button Press this button repeatedly to increase the parameter under adjustment by one decrem...

Страница 7: ...as still as possible 3 2 Enter Setting mode Press the function button for about 4 second extended press the oximeter will enter into Setting mode and you will find a parameter item which include its t...

Страница 8: ...h After turning on the oximeter each time the function button is pressed the oximeter will switch to another display mode shown as Fig 7 4 3 Factors that may affect the measurement During operation th...

Страница 9: ...gram measurement can also provide a plethysmogram wave During this mode the PR tone is dumb Fig 7 3 SpO2 plethysmogram wave PR tone modulation Beeps in sync with the patient s pulse even under most ch...

Страница 10: ...disinfecting 1 Clean or disinfect the sensor before each use 2 Unplug the sensor from the oximeter before cleaning and or disinfecting 3 Clean the external sensor surfaces and patient contact surface...

Страница 11: ...ted 2 The connection between the Probe and Oximeter is loose 1 Connect the sensor 2 Please check if the probe was connected with oximeter correctly 5 5 1 Service Method a Service hours 9 00am 5 30pm M...

Страница 12: ...he user s request Return Policy Warranty and non warranty returns should be handled in the following manner Contact the Technical Support Department and obtain a RMA Return Materials Authorization num...

Страница 13: ...Display Type OLED double color Parameters SpO2 PR SpO2 plethysmogram waveform PR bar Mode 3 display modes Record Patient ID 1 10 Data record Up to 72 hours Data transmission Transmission method Cable...

Страница 14: ...eclaration Electromagnetic Immunity for Equipment and Systems that are not Life Supporting 61000 4 6 Radiated RF IEC 61000 4 3 3V m 80Hz to 2 5 GHz d P V1 5 3 80MHz to 800MHz d P E1 5 3 800MHz to 2 5G...

Страница 15: ...minimum distance between portable and mobile RF communication equipment transmitters and the Handheld Pulse Oximeter as recommended below according to the maximum output power of the communications eq...

Страница 16: ...Vpod Instruction Manual 15...

Отзывы: