Virtue SPIRE III Скачать руководство пользователя страница 7

 

RACEWAY DISASSEMBLY

 

//

The Spire III Raceway can be detached by unplugging the wiring 

harness from the motor and pressing the Raceway Removal Tab on 

the bottom of the tray then slide the Raceway and motor assembly 

down and out.  To reinstall the Raceway, slide the back of the Race-

way into the two slots first  and then snap the Raceway Release tab 

back into place. Take care to Make sure the wiring harness is not 

pinched.

PCB ELECTRONICS PACKAGE REMOVAL

 

//

The PCB electronics package can be removed after unplugging the 

motor and removing the Raceway. At the front of the tray gently bend 

each corner of the front tray PCB tabs away from the PCB and 

remove the PCB package. To reinstall the PCB slide the back of the 

PCB into the tray and then flex the front tray tabs around each side of 

the front of the PCB.

There is no particular maintenance needed for the Spire III. Keeping it clean and using fresh batteries is all that is required. 
If you leave the Spire III unused for more than 6 months it is suggested to remove the batteries to avoid damage due to a 
possible leaking battery.

For normal cleaning of the Spire III, remove the Spire tray and set it aside. The shell can be washed under the sink using 
warm water and mild detergent. Do not use a dishwasher, boiling water or other strong chemicals as this can weaken the 
plastic. Remove the Spire III Drive from the tray and wash it like the shell.
Remove and clean the Raceway by hand. Generally, it's ok if the Raceway and motor assembly gets wet, but do not 
submerge it in water to prolong the life components.

 The PCB Electronics Package can also be removed and cleaned by hand. Do not submerge the PCB in water. Clean the 
paint off the PCB using a cotton swab or paper towel. All of the electronics are conformal coated for weather and paint 
resistance, however prolonged exposure to paint will eventually corrode away the coating and damage the electrical 
components. 

MANUAL

 

 

//

  PAGE 6

CLEANING

+ MAINTENANCE

 

Содержание SPIRE III

Страница 1: ...SPIRE III MANUAL BUILT TO WIN PAINTBALL LOADER...

Страница 2: ...h batteries are installed Power save mode prolongs battery life by shutting down Reload Indicator and LEDs The LED will occasionally flash green to let you know it s on LENGTH 9 5 WIDTH 4 HEIGHT 3 9 W...

Страница 3: ...quality alkaline or lithium ion batteries Using rechargeable batteries is not recommended and will cause performance issues 4 Insert Spire tray back into the loader and push down until black lock cli...

Страница 4: ...ries For maximum feed and to prevent feeding or performance prob lems please use fresh high quality batteries It is recommended to use either alkaline or lithium ion type batteries Do not use recharge...

Страница 5: ...Spire III is muted by default and remembers your previously saved setting The Force Feed button also allows you to enter the Spire III Programming Menu by holding this button in when you turn the Spi...

Страница 6: ...ace REMOVING LID INSTALLING SPEED FEED The lid of the Spire III is installed using a quick mount system To remove the lid open it to its open position Using your finger press in the lock tab on the in...

Страница 7: ...t clean and using fresh batteries is all that is required If you leave the Spire III unused for more than 6 months it is suggested to remove the batteries to avoid damage due to a possible leaking bat...

Страница 8: ...4 times when the Reload Indicator activates The programming menu can be accessed by turning the Spire III ON while holding in the Force Feed Programming button on the bottom of Spire III and then rele...

Страница 9: ...etting 2 Reload Indicator LEDs activate after the Smart Ramp goes up and the motor spins 5 times Setting 3 Reload Indicator LEDs activate after the Smart Spring Ramp goes up and motor spins 10 times G...

Страница 10: ...s If the Spire III stops spinning before the balls stack is full you can raise this setting Too high of a setting can cause unwanted pop corning and too low of a setting can cause the Spire III to sto...

Страница 11: ...exit the programming menu Start the application and press Upgrade Firmware The app will show a your loader s serial number in the list Tap on the serial loader number and wait until the application i...

Страница 12: ...to make sure 4 Check that the cable between main PCB and motor is connected on both ends SPIRE III LED OR SPEAKER NOT WORKING 1 Make sure the LED and Speaker are turned on in the program menu or perfo...

Страница 13: ...mance 2 Ensure that you have the latest firmware update by using the Spire App to download and flash your Spire III 3 Check that the Yellow Drive Pressure Setting is set to Auto Mode Or if necessary s...

Страница 14: ...ollowing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC ID SH6MDB...

Отзывы: