Chapter 3 Deployment
Manual VIPA TM
3-16
HB39E - TM - RE_900-2H611 - Rev. 10/16
TM - PLC linking
For the further approach there is condition your Teleservice module has
valid IP address parameters and the Web page of the TM may be
accessed.
To get access to the VIPA PLC, the VIPA CPU is to be connected to the
MPI jack of the Teleservice module via a suited MPI cable.
If there is an Ethernet CP within your PLC, for TM access you may connect
it to Ethernet instead to MPI.
Switch-on the power supply of the CPU and switch the CPU to RUN.
•
Open the concerning Web page of the Teleservice module. Now you are
requested for access parameters.
Per default the TM has the following access parameters:
Access parameters
User name: adm
Password: adm
•
After entering of
User name
and
Password
the Web page of the
Teleservice module is opened.
•
Open with
Configuration
>
IO Server Config
the page to preset I/O
server.
Preconditions
Connect VIPA PLC
via MPI
Configure VIPA
PLC in TM