 13

AlphaCom XE - Installation, Configuration & Operation

A100K10805

Indicators

The card has a number of LEDs to indicate the board and Ethernet 

status.
See section 12.4.1 for other possible Ethernet LED indications.

Filter board

A filter and connection board, FBIP, must be inserted from the rear side 

of the cabinet in the same card position as the AMC-IP card. This filter 

board is not needed in AlphaCom XE1 or XE7 where all EMC filters and 

external connectors are integrated in the backplane.
The USB connector is not supported in AMC-IP board 11 versions.

2.2.8  APC - Program and Clock Board

The APC Board is used in AlphaCom XE20 and XE26 to control the 

backplane board clocking. It also controls the speed of the fans. This 

board must be installed in position 26.
It contains circuitry for 6 audio program feed channels with galvanic 

isolation. Each channel has separate input level controls.
The card has 6 RCI alarm inputs which can be used for programmed 

actions. The inputs accept a closing contact referred to ground.
A reset button is used to reset and restart the entire server. The reset 

LED on the AMC-IP board will turn red during reset.
An APC connection kit 100 9503 000 needs to be purchased to connect 

alarm and audio sources. The kit contains a filter board, a connection 

board, and an interface cable.
Further information is found in datasheet A100K10011.

2.2.9  ASLT - Subscriber Line Board

Two boards for 12 intercom subscribers are normally delivered with the 

server. The maximum number of cards in one server is:
AlphaCom XE7:   6  

in positions 1-6

 

AlphaCom XE20:  17  

in positions 1, 8-23

 

AlphaCom XE26:  23  

in positions 1-23

Each board contains circuitry for 6 subscriber connections and one 

measurement channel for voice switching control.
The board provides 6 remote control software controlled outputs. The 

line monitoring reports errors on all subscriber lines.

AlphaCom XE20/XE26

Intercom stations and control outputs are connected to a connection 

board mounted on the server connection field.
2 subscriber connection boards (100 9930 200) with 1.5 m connection 

cables (100 9501 011) are delivered with the servers.
5 m (100 9501 021) and 10 m (100 9501 023) subscriber connection 

cables with filter boards can be purchased separately if the distribution 

field is placed away from the server. These cables have a D-sub 

connector for the filter board and unterminated wires for the distribution 

field. Color code is packed with the cables.

Filter card with RJ connectors

This board (100 9501 041) has RJ45 connectors for connection of 6 

CAT5 installation cables to the back of the server. Station cables can be 

plugged directly to this card. The 7

th

 RJ45 outlet is for 6 RCOs.

Hot-Plug

AMC board status

Syncronisation

AUX (not in use)

Reset initiated

Link status (Eth0)

Tx/Rx (Eth0)

Flash activity

Link status (Eth1)

Tx/Rx (Eth1)

Cold start button

Exchange

reset

Software

starting

Startup

running

Normal

operation

Incorrect

NVRAM

version

OFF

OFF

OFF

OFF

OFF

OFF

RED

RED

RED

RED

AMBER

GREEN

flash

GREEN

flash

GREEN

GREEN

GREEN

AMBER

flash

FLASH

Link Up

Speed

negotiation

Receive

Flash1

Flash2

data

activity

activity

Transmit

data

~

RS232
RS232/422/485

USB

Future use

Eth1
Eth0

FI

LT

ER

 B

O

A

R

D

0

0

1

1

 

GND

Signal

ground

1...6

1...6

RCI

PROGRAM

CONNECTION BOARD

P1
P2
P3
P4
P5
P6

P1

P2

P3

P4

P5

P6

A1

A2

A3

A4

A5

A6

Alarm

inputs

Program

sources

From APC board

Hot plug

out

Reset

Pr

og

ra

m

 p

re

se

t v

ol

um

e

APC board

a

b

c

d

123456

MRBD

1 . . . . 6

RCO

 

1

2

3

4

5

6

Relay board

CONNECTION BOARD

F

IL

T

E

R

 

B

O

A

R

D

C

O

N

N

E

C

T

IO

N

 F

IE

LD

5/10m

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

1 2 3 4 5

STENTOFON

VMP-

D619

*

#

1

2

3

4

5

6

7

8

9

0

C

M

VINGTOR

RCO1-6

Содержание AlphaCom XE Series

Страница 1: ...TECHNICAL MANUAL AlphaCom XE Installation Configuration Operation A100K10805 ...

Страница 2: ...10 HKL Revised LCM figures 1 2 4 3 2011 HKL XE7 backplane fig 1 3 18 3 2011 HKL AMC board jumpers 1 4 16 7 2012 HKL AlphaWiki ref 1 5 28 8 2013 HKL Port pin out RIO cabling 1 6 31 01 2014 ER Last 2 2 3 deleted 1 7 8 6 2015 HKL Battery 2 2 7 Related Documentation For further information refer to the following documentation Doc no Documentation A100K10176 RIO Remote Input Output Unit A100K10300 Pris...

Страница 3: ...ard 15 2 2 12 AGA General Purpose Audio Interface 16 2 3 Performing a Cold Start 16 2 3 1 Cold start procedure 16 2 3 2 Cold start AMC application only retain IP setting 17 2 4 Modifying Factory Default Settings 17 2 5 Default Directory and Feature Numbers 17 2 5 1 Station numbers 17 2 5 2 Class of Service CoS 17 2 5 3 Features during connection 18 2 5 4 Voice and display messages 18 2 5 5 Station...

Страница 4: ...ration 36 6 2 1 Overview 36 6 2 2 Insert AlphaNet license 36 6 2 3 Create all the exchanges in the AlphaNet 36 6 2 4 Create AlphaNet data routing 36 6 2 5 Create AlphaNet audio channels 38 6 2 6 Cluster node programming 38 6 2 7 Update the directory in each exchange 39 7 Multi Module Network 41 7 1 Overview 41 7 2 Installation 41 8 External Communication 43 8 1 SIP Trunk License 43 8 2 Gateway Con...

Страница 5: ...on 55 9 4 2 Hardware and license requirements 56 10 System Monitoring 57 10 1 System Logging 57 10 1 1 Local log file and AlphaWeb 58 10 1 2 System clock and event time stamps 59 10 2 System Information and Statistics 60 10 2 1 SNMP MIBs 60 10 2 2 System information 60 11 Upgrade Backup 61 11 1 Software Upgrade 61 11 2 Configuration Backup and Restore 61 12 Appendix Technical Data 62 12 1 Specific...

Страница 6: ... server It allows users to log in using a standard web browser such as Internet Explorer or Firefox to operate and manage the AlphaCom XE system Logging and monitoring AlphaCom XE comes with powerful logging and monitoring functions providing the user with good oversight of system status and events Software and system upgrade AlphaCom XE comes with powerful software and system upgrade capabilities...

Страница 7: ...o management services The authentication process uses an MD5 authentication routine 1 1 2 Separate management interface AlphaCom XE comes with a separate Ethernet interface which can be dedicated to management This allows the administrator to build a separate administration VLAN that is dedicated only to administrators 1 1 3 Internal firewall AlphaCom XE has an internal firewall allowing the netwo...

Страница 8: ...he default factory settings are often required for instance if the default numbering plan and naming in the directory shall be updated to reflect the floors in a building then the optional steps should also be performed 2 1 Making a Network Plan Make a plan of the network topology as shown in the example below Oslo head office SIP ISDN Gateway iPBX Public telephone network Internet VPN IPsec WAN I...

Страница 9: ... Internet and AlphaNet IP communication The serial ports with RS232 and RS422 485 interfaces are used for connecting to equipment using these protocols The two NO switches on the RCI connectors can execute programmable functions The 12 RCOs are connected to optional MRBD relay boards and can be programmed to execute functions such as door control Connectors 5 and 6 on the first ASLT line board are...

Страница 10: ... 2 4 Installing the AlphaCom XE26 cabinet More information is found in Datasheet A100K10317 There are three standard cabinet models 19 rack mounting floor cabinet and floor cabinet with distribution field The cabinet has room for installation of 26 circuit boards in total one AMC IP processor board one APC program clock board and up to 24 feature boards The server also includes a mains power suppl...

Страница 11: ...trolled RCO outputs switch selection Line points All subscriber line connections are made to the LCM board Any mix of ASLT ATLB and ATLB 12 boards may be used Max 36 analog intercom stations with 6 x ASLT boards Max 72 analog telephone lines with 6 X ATLB 12 boards RCO 6 x relay contacts potential free or 24 V switch selection 6 x output to optional MRBD Relay board RCI 1 6 x closing contact input...

Страница 12: ...NTOFON AlphaCom XE series The board is made for critical communication and security solutions featuring an embedded real time Linux operating system integrated media processing engine packet processing engine HW encryption and storage module The AMC IP board provides full backwards compatibility for both software and hardware All traditional AlphaCom services and interfaces are supported The board...

Страница 13: ... errors on all subscriber lines AlphaCom XE20 XE26 Intercom stations and control outputs are connected to a connection board mounted on the server connection field 2 subscriber connection boards 100 9930 200 with 1 5 m connection cables 100 9501 011 are delivered with the servers 5 m 100 9501 021 and 10 m 100 9501 023 subscriber connection cables with filter boards can be purchased separately if t...

Страница 14: ...e RCOs 1 6 are associated with the board in position 1 and RCOs 7 12 in position 2 See also datasheet A100K10315 Cabling Desktop stations are connected to the line on RJ45 wall sockets Further information on the ASLT board is found in datasheet A100K10012 2 2 10 ATLB Telephone Line Board The ATLB board contains circuitry for connecting 6 two wire DTMF telephones used as AlphaCom subscribers The bo...

Страница 15: ...e ALTB board can be placed in any board position 1 6 The example drawing shows an ATLB board in position 2 If possible avoid using boards in position 1 as connection points 5 and 6 are used for program input by default Further information on the ATLB board is found in datasheet A100K10237 2 2 11 ATLB 12 Telephone Line Board ATLB 12 has the same functions as ATLB except that it has 12 two wire DTMF...

Страница 16: ...face cable AGA boards can be placed in board positions 1 6 in an XE7 server but the number of inputs are reduced to 6 per board Input adjustments are performed by potentiometers 4 6 8 10 12 and 14 The program sources are connected to the c and d terminals on backplane connectors Audio distribution in AlphaNet Each board provides 6 audio channels between the servers There can be any number of AGA b...

Страница 17: ...bers The number series 101 to 499 and 5000 to 5152 are default directory numbers for all AlphaCom XE servers The directory numbers are connected to physical numbers in the range from 1 to 552 where the physical numbers are given by the subscriber point on a board in a certain position in a defined module Since the card positions 2 7 are not used in XE20 the corresponding default subscriber numbers...

Страница 18: ... 4 Voice and display messages When the station is idle entering a digit number code will show different menus on the station display Navigation in the menus is done using the 7 8 and 9 keys DISPLAY MENUS Feature No CoS1 CoS15 Info Service 60 X Group Call menu 610 X Absent menu 611 X Message menu 612 X Audio Program menu 613 X Name directory 614 X Features menu 615 X Service menu 616 X Conference m...

Страница 19: ...ST Disconnect Group Call 7884 Call Request to CRM stations 621 X Ringing Group 6701 6710 X X Call Request alarm 622 X CONFERENCE Call Request ordinary 623 X Simplex Conference 1 50 8201 8250 X Call Request transfer 7870 X Simplex Conference OFF 8200 X PROGRAM DISTRIBUTION Duplex Conference 1 20 8301 8320 X Program 1 6 801 806 X Duplex Conference OFF 8300 X Program 7 70 X ALARM Next program step up...

Страница 20: ...re backup to EPROM 7820 Reset board error 7871 AGA audio test 7872 Set access to feature 7873 Tone test 7885 Block alarm input 7888 Unblock alarm input 7889 2 5 7 Control room stations Stations used for control rooms such as guard locations in prisons buildings parking facilities etc may be a dedicated Control Room Master CRM station or a normal master station with display CONTROL ROOM STATION FEA...

Страница 21: ...splay where the second display can be programmed with DAK key names has lead to a series of specific feature codes DUAL DISPLAY FEATURES Feature No CoS1 CoS15 Alphanumeric search 9537 X Edit DAK text 9540 X Program DAK 9541 X Dual Display menu 9542 X Dual Display DAK page down 9543 X Dual Display DAK page up 9544 X 2 5 10 Telephone functions When calling an intercom station from an external teleph...

Страница 22: ...ted in AlphaWeb by selecting Filters in the System Configuration menu see section 3 4 4 AlphaWeb XE Interfaces Routers IP Station Upgrade Licensing Filters Stations User Management Logging Time and Date Host Names Messaging System Configuration System Upgrade Custom Scripts System Recovery M100 Config Backup System Maintenance RingMaster External Systems About Help System Monitoring Node Informati...

Страница 23: ...hould be saved to the configuration file by clicking Save The configuration data is then only saved to the AlphaCom configuration file and not applied to the running configuration To get the new configuration data applied to the running configuration click Apply 3 2 Changing Default User Name and Password It is recommended to change the default user names and passwords for security reasons Select ...

Страница 24: ... parts Network address identifies a whole network or subnet Host address identifies a particular device s connection or interface to that network This division is used to control how traffic is routed in and among IP networks It is the Subnet Mask that decides which part of the IP address is the Subnet number and which part is the Host number 3 4 2 IP interfaces To connect the AlphaCom XE to your ...

Страница 25: ...ute by clicking Add Route Default IP route Enter only Gateway IP address and Out Interface Ethernet port eth0 1 Network route Enter Destination IP address Destination Mask Gateway and Out Interface Ethernet port eth0 1 Host route Enter Destination IP address Gateway and Out Interface Ethernet port eth0 1 3 4 4 Internal firewall AlphaCom XE has an internal firewall allowing the network administrato...

Страница 26: ...nt AlphaPro 11 can also upload configuration information from a server exchange AlphaPro 11 connects to a server exchange via the IP network or a local RS232 interface 4 1 1 AlphaPro versions AlphaPro 11 comes in two versions A hardware dongle is used to differentiate between the versions There are two types of hardware keys one for parallel port and one for USB port The versions of AlphaPro are A...

Страница 27: ...the instructions on the screen You can safely answer YES to all questions 4 2 2 Insert the HW dongle Insert the hardware dongle in the PC s parallel or USB port depending on the dongle type Leave the dongle in the PC during programming and transferring of data to the server If the dongle is not inserted the AlphaPro will run in AlphaPro M mode You will still have access to all functions except Alp...

Страница 28: ...st exchange node number is 1 Select the desired type of node exchange type AlphaCom E is default Select the display language for the stations in the exchange Available languages are Danish Dutch English Finnish French German Hebrew Norwegian Spanish and Swedish English is the default Checkbox for AlphaNet Adm Here Creates an exchange with full database which can be configured from this PC Creates ...

Страница 29: ...cation is established and the buttons become active L L If the PC is not connected to the exchange a fault warning will pop up You may skip the data transfer until data changes have been carried out off line 4 4 2 Send information to the exchange Click SendAll to send all data Click SendChg to send changed data only An icon in the lower right corner flashes during transmission The transmission may...

Страница 30: ...f the node number in the exchange is not the same as the node number in the AlphaPro database the login will fail This command allows you to modify the node number in the exchange After Autoload the exchange will have node no 1 In a network of exchanges AlphaNet each exchange must have its unique number 4 6 AlphaPro Menu Structure Exchange System Directory Features Audio programs Pocket pagers Sim...

Страница 31: ... tones Members Members Groups Name Access level Priority General Directory Numbers Directory numbers Display text Feature description CoS restrictions Hide info in idle Visibility Timings General settings Pager settings Number Name Driver Type Receiver number Pocket Pagers Pocket Pagers Global Groups Net Routing Group Members Net Audio Groups Users Reports Group User preferences Event actions Auto...

Страница 32: ...nnection point on the ASLT or ATLB card IP stations must also be given physical numbers to follow the same logic This number can be any number below 552 but must not overlap star wired station physical numbers L L Start numbering the IP stations from 552 and downwards to avoid occupied number problems if the exchange is extended with more star wired stations later on Directory Number is the number...

Страница 33: ...ckbox for registration with directory number AlphaCom XE can use both methods for identifying an IP station When configuring an IP station in AlphaPro you must select which methods to use to identify the IP station The advantage of using registration by directory number is that it is easier to replace the station at a later stage as this does not require new settings in AlphaPro Directory Number r...

Страница 34: ...ECT System comprises the following components IP DECT Server 6000 Base Stations Repeaters Administrative Computer Handsets and accessories The IP DECT Server 6000 communicates with the AlphaCom exchange over a LAN Local Area Network The configuration process includes Configuring the Server Configuring the Base Station Registering a Handset Subscribing a Handset Configuring the Exchange The complet...

Страница 35: ... and calls in the correct order Alternative routing Alternative routing of calls allows call completion even when the primary AlphaNet route is down For alternative routing AlphaCom XE can either use its secondary IP interface or route the call over a traditional interface such as an analog or digital line Backwards compatibility AlphaCom XE provides 100 backwards compatibility between traditional...

Страница 36: ...changes in the AlphaNet Create AlphaNet data routing Create AlphaNet audio routes Update the directory 6 2 2 Insert AlphaNet license This must be done if VoIP AlphaNet should be used see section 3 3 6 2 3 Create all the exchanges in the AlphaNet Define the exchanges in AlphaPro under Network Exchanges See section 4 3 on how to create the exchanges L L In some cases it is not desired to program all...

Страница 37: ...ree ACDP Link AlphaCom Data Protocol Click Change Tick the Enabled checkbox to enable the port and select the serial port for AlphaNet from the Port Type drop down list Set Link Type as Stentofon Link Layer AlphaNet Click OK and close the serial port window Select Net Routing Click Insert Select the remote AlphaCom node for the AlphaNet Configure the primary route Select the ACDP Link that was con...

Страница 38: ...s Select the AlphaCom exhange Click the Exchange System icon Click Net Audio Click Insert Select the destination node and click Select Enter the physical numbers in the Source and Destination nodes as shown The module position and line numbers are automatically defined when the physical number is entered See the appendix for an overview of physical numbers in AlphaCom Confirm by clicking OK Repeat...

Страница 39: ...as a global number feature 83 If the number exists from before in any of the other exchanges it will be deleted AlphaNet Visibility will be set to Cluster Automatic in the other exchanges Modifying When modifying the number or name of an existing global user do the modification in the exchange where the user is physically connected i e where the visibility is set to Cluster Global Deleting When de...

Страница 40: ...rom the Visibility drop down list Confirm by clicking OK Cluster Global can also be set from the Directory Feature menu All stations can then be set in one operation Manually create directory number for Global Numbers for AlphaNet Click the Directory Features icon Click Insert Select Global Number for AlphaNet 83 from the Feature drop down list Enter the node number for the exchange Enter the dire...

Страница 41: ... Main features of AlphaCom XE IP based Multi Module Same high degree of feature integration as conventional multi modules No additional AlphaCom hardware required License is needed in the master module only Point to point connections not in a ring as in conventional multi modules The modules need to be on the same LAN Optional Autonomic mode The AMC Master can be set to copy its contents to the sl...

Страница 42: ...ster license key to enable the Multi Module see section 3 3 AlphaPro Click the Exchange System icon Select the multi module exchange from the list Click the System button Select Eth1 as the Default VoIP Port and check the Address Enter the IP address of the slave modules L L Only the Master Module supports serial port drivers and other central equipment and licenses like RIO Paging AlphaNet SIP tr...

Страница 43: ... AlphaCom AudioCodes interconnection are covered A full description including AudioCodes programming is found in the SIP Gateway Configuration Guide A100K10333 and in AlphaWiki under the SIP category See also the SIP GSM Gateway Configuration Guide A100K10390 The configuration of AlphaCom XE with the SIP gateway includes the following steps Using AlphaWeb Assign IP address to the AlphaCom Ethernet...

Страница 44: ...he button next to the Select Exchange drop down list to create a new exchange The exchange Type must be set to SIP Node Click the radio button for SIP Trunk Line and enter 10 5 101 44 The SIP Trunk IP address must be identical to the IP address of the SIP Gateway L L If AlphaCom is configured with a SIP Registrar node in addition to the SIP Trunk node the SIP Registrar node must have a lower node ...

Страница 45: ...licking the SendAll button Reset the exchange after the send operation is completed 8 5 Billing System The VINGTOR Billing application makes it possible to manage and administer the communication fees and expenses for your VINGTOR ACM system The application provides access authorization to external communication The calling users will be identified based on PIN or subscriber number Each user will ...

Страница 46: ...dard web browser to log into the system From the web browser the administrator is able to Print billing invoices Print and view usage reports Change billing setup Five different product versions of the Billing System are available with capacity from 2 to 32 external trunk lines all catering to a maximum of 400 users See the manual A100K10590 Billing System Configuration Guide for further informati...

Страница 47: ...broad set of applications and functions some of which are Live PA and group call broadcast with recall for handling feedback and verifying messages Pre stored PA and group call broadcast Scheduled or event based PA and group call broadcast Auto attendant with voice guided menus for handling incoming calls Voice response for call request waiting messages and absence messages Integration with 3rd pa...

Страница 48: ...he web interface AlphaWeb The standard messages comprise Absence messages Information messages Help messages Alarm messages The types of messages that actually become available depends on the installed Audio Messaging license Install language package The language file has the format asvp_xx_06 00 apkg where xx is the actual language and 06 00 is the version number Before the installation can start...

Страница 49: ...udio if high quality playback is required The audio file must be in WAV format The following codecs are supported PCM files at 16kHz sample rate linear 16bit mono 1 channel MS ADPCM at 16kHz sample rate mono 1 channel IMA ADPCM at 16kHz sample rate mono 1 channel When a request is made to AlphaCom XE to play a message it will search for matching group index in the following order 1 Station recorde...

Страница 50: ...one 70 Station reset 10 42 No messages None ALARM MESSAGES Dir no Feature Message Group Group Index Default English ASVP message Minimum license required 8191 Alarm Message 1 30 1 Fire alarm Please stay calm and leave the building through the nearest exit All exits are marked with green light Don t stop but proceed completely out of the building Wait for further information outside Basic 8192 Alar...

Страница 51: ...ssages Enhanced 8180 660 669 Voice Mail messages Enhanced A station recorded message will mask any corresponding web loaded message or ASVP message When a station recorded message is deleted the web loaded message will be unmasked if present A station recorded message will be stored as a WAV file in the flash memory of the AMC IP board and can be accessed from the System Configuration Messaging pa...

Страница 52: ...ages Message Group 11 index 1 3 Any number of Voice Alarm Messages Message Group 30 Up to 10 Mbyte of customized WAV files Approx 21 min 20 sec speech Recall function Delayed group call to prevent feedback Absence Messages 771 779 Mail Messages 660 669 9 2 4 Supported audio file formats AlphaCom can only play back WAV container file format with 16kHz sample rate single channel mono and one of the ...

Страница 53: ...4 or 765 84 2 Press the key to record a message 3 Press the key to stop the recording and listen to the message 4 Press 8 to dispatch the message or Press to make a new recording Press 7 to repeat the message Hang up to cancel 9 3 3 Optional settings The recall user interface and the recall attributes can be altered by modifying parameter 2 set in AlphaPro of the recall directory number By default...

Страница 54: ...econd group call go through if the overlap is less than the number of stations specified Disable simultaneous group calls in AlphaPro Select Exchange System System Calls and Options Disable Simultaneous Group Calls by unticking the checkbox only one group call can be active at a time Each group call can be assigned one out of four available Setup Priority levels With Simultaneous Group Calls A gro...

Страница 55: ...he voice menu Adding more auto attendant numbers Up to 3 auto attendant numbers are supported depending on the license installed Directory numbers for the first auto attendant is included by default For the second and third auto attendants you have to add new directory numbers from AlphaPro Adding a second auto attendant In Directory Features click Insert and add a new number with the following pr...

Страница 56: ...igit routing is done in the DAK table of physical number 502 9 4 2 Hardware and license requirements Hardware The auto attendant feature requires AMC IP hardware version 8000 5 or 8000 6 Black PCB License Auto attendant requires a Basic 1 auto attendant or Enhanced 3 auto attendants Audio Messaging license ...

Страница 57: ...le to configure the events that should be included in the system log Click the Exchange System icon Click System Select Logs and Errors Select the events you want to be reported Confirm by clicking OK It is also possible to configure customized events in the system log This is done in AlphaPro by using Event programming Call statistics log The call statistics log provides an event for each call in...

Страница 58: ...nfiguration Logging The list shows the log destinations and current configuration status The configuration may be altered as follows Click Edit to configure the destination Click Del to delete the option Click Add to create an additional item of the same type e g two e mail addresses To configure click Edit and fill in the dialogue box according to destination type In the Pri Level drop down list ...

Страница 59: ...ing the log the hyperlink for the log file name may be selected to download the log to your PC 10 1 2 System clock and event time stamps To configure the system clock and event time stamps Log in to AlphaWeb Select System Configuration Time and Date Select the time zone from the Select Your Zone drop down list Set the local time by entering values in the Date and Time fields or enter the IP addres...

Страница 60: ...and statistics Log in to AlphaWeb Select System Monitoring Node Information Click Information to see general system information and SW and HW configuration Click Processes to see software state and versions SNMP definition Simple Network Management Protocol SNMP is a set of protocols for centralizing the management of IP networks It is used for both collecting information from and configuring the ...

Страница 61: ... AMC system package Log in to AlphaWeb Select System Maintenance System Upgrade Click Browse to select the appropriate apkg file Click Upload to transfer the AMC system package to AlphaCom Click Install to start the installation L L AlphaCom XE will do an MD5 check to verify that the software package is valid The MD5 digital signature is used to hinder possible virus infections 11 2 Configuration ...

Страница 62: ...0 102 physically 138 Entertainment channels On APC board NA 2 6 6 Per AGA board NA 6 16 16 Remote control outputs Per ASLT board NA 6 12 on back plane 6 6 Remote control inputs On APC board NA 2 6 6 Serial port COM0 RS232 9 pin D sub RS232 RJ45 COM1 RJ45 RS232 422 485 Ethernet 2 x RJ45 10 100 Mbps Traffic capacity SIP trunks 30 channels VoIP AlphaNet 30 channels Digital trunks 32 channels Analog t...

Страница 63: ...al numbers 7 12 and 283 288 Board in slot 3 has physical numbers 13 18 and 289 294 and so on Since card positions 2 7 are not used in XE20 the corresponding physical numbers are therefore missing PHYSICAL NUMBER TABLE AlphaCom modules XE7 XE20 XE26 Single or master 1 36 1 6 143 138 1 138 1st slave 139 174 139 144 187 276 139 276 2nd slave 277 313 277 282 325 414 277 414 3rd slave 415 451 415 421 5...

Страница 64: ...ON 1 8 NO S200 Ethernet settings 1 Port 1 Auto Negotiation enable 2 Port 0 Auto Negotiation enable 3 Port 1 Speed 100 Mbps OFF 10 Mbps 4 Port 0 Speed 100 Mbps OFF 10 Mbps 5 Port 1 Duplex full OFF half 6 Port 0 Duplex full OFF half 7 Ethernet LED configuration bit 0 8 Ethernet LED configuration bit 1 ON ON ON ON ON ON OFF ON S601 System settings 1 Linux Console enable 2 Self test 3 Reserved 4 Reser...

Страница 65: ...ity Tx activity Tx Rx act ON OFF 10 Mbps 100 Mbps Link down Link up Activity Full Duplex Collisions Link up in full Duplex ON ON 10 Mbps 100 Mbps Link down Link up MII isolation Full Duplex Collisions Link up in full Duplex Blink rate 100 ms 12 5 Port Pin Out The AlphaCom XE servers have two serial and two Ethernet ports AlphaCom XE20 XE26 For AlphaCom XE20 and XE26 the serial ports are available ...

Страница 66: ...the AMC IP board to the ON postion as well as move the two jumpers on the AlphaCom XE7 backplane to the RS485 position 1 1 1 8 8 8 Eth_Tx Eth_Tx Eth_Rx Ref Ref Eth_Rx Ref Ref 1 8 1 8 RS232 1 1 1 Serial ports 1 8 1 8 1 1 5 5 6 6 9 9 Ethernet ports 0 0 1 1 Tx Rx Gnd RS422 RS485 RS232 RS485 RS422 Rx Gnd Gnd Tx A B A B Tx Tx 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 2 3 5 Rx Rx AMC XE7 AlphaCom XE1 The connecti...

Страница 67: ...n mode voltage that can be impressed on the receiver inputs If you want to connect it use pin 5 on the AlphaCom RJ45 port to pin 5 on the RIO 15 pin D SUB Programming is the same as with conventional AMC L L Note that when using RS485 the switch S601 8 on the AMC IP board must be set to the RS422 positon and two jumpers must be moved from the RS422 to RS485 position The jumpers are located on the ...

Страница 68: ...m is certified to meet the requirements in NS EN ISO 9001 Zenitel reserves the right to modify designs and alter specifications without notice ZENITEL PROPRIETARY This document and its supplementing elements contain Zenitel or third party information which is proprietary and confidential Any disclosure copying distribution or use is prohibited if not otherwise explicitly agreed in writing with Zen...

Отзывы: