19
ACTO
5 - Description of the LEDs in the circuit:
Buttons in the circuit
Abbreviation
Description
P/P
Controls opening and closing the gate
PROG
Press to enter travel programming
MEMO RX
Press to enter programming or deletion of remote controls, during travel programming selection of the direction of opening
Preliminary check:
Check the LEDs for diagnosis of the inputs, PHC, PHO, STP and ALIM. must be on.
6 - Travel programming
Procedure for travel programming:
Abbreviation
Description
Alim.
Shows whether there is mains power (lit if there is mains voltage)
PHC
Displays the status of the PHC input (terminal 11), if not engaged the red LED remains lit, if not used then jumper between
terminal COM and PHC
PHO
Displays the status of the PHO input (terminal 12), if not engaged the red LED remains lit, if not used then jumper between
terminal COM and PHO
STP
Displays the status of the STP input (terminal 13), if not engaged the red LED remains lit, if not used then jumper between
terminal COM and STP
N.B.: If the system has no photocells, sensitive edges or stop buttons (the PHC, PHO and STOP inputs must be jumpered with the common, ter-
minal 14), do not activate the photo-test function.
4.7 - Connecting the aerial
to increase the range use cable RG58 to connect the aerial of the flashing light to terminal number 24 and 25 or connect aerial ZL43 as shown in the figure:
Fig. 13
RX1
RX2
+24 Vdc
COM
PHC
-
TX1
TX2
14
13
12
11
10
9
NO COM NC
-
+
NO COM NC
-
+
-
+
-
+
NO COM NC
-
+
-
+
+ PHT
+24 Vdc
+PHT
PHO
-
COM
14
13
12
11
10
9
15 16
ANTShield
Fig. 14
APERTURA
APERTURA
Fig. 15
EN
OPENING
Содержание Elvox RS16
Страница 62: ...60 ACTO 1 61 2 61 3 62 4 62 5 LED dip switch 67 6 67 7 68 8 68 9 69 10 70 CEI 2002 96 2004 108 EL...
Страница 74: ...72 ACTO...
Страница 75: ...73 ACTO...