N.B.: Do not change the wiring of the electric motor, the control unit is configured by default to open the gate to the right, to reverse the opening
direction, follow the procedure described in point 2:
1. Move the gate to about 1 metre from completely closed, press and hold the PROG button until the flashing light comes on steady, release the PROG
button
2. Press and release the P/P button, the gate must close at reduced speed. If instead it opens, do not change the wiring of the electric motor but
press the MEMO RX button to reverse the direction. The flashing light stays on with a steady light
3. As soon as it reaches the CLOSING limit switch, the automation system starts opening at reduced speed until the OPENING limit switch trips and the
flashing light stays on with a steady light
4. From the moment the gate stops due to the opening limit switch tripping, the control unit saves the total travel of the gate and starts counting the automatic
closing time, maximum time 250 seconds, once the required time has elapsed, press button P/P; the automation system will start to close at cycle speed.
5. The gate slows down and then stops when the closing limit switch trips, exiting programming and the flashing light switches off.
N.B.
The first closing and first opening is performed at slowdown speed, any change in the dip switches or POWER trimmer must be made when the gate
is closed.
- To view the operation of the magnetic limit switches just mechanically unlock the motor and enter the learning procedure described in point 1. Once the
flashing light is on steady, move the gate leaf till the opening limit switch trips, if the magnet of the limit switch is read, the flashing light will start flashing,
repeat this procedure also for the closing limit switch magnet.
7 - Remote control programming
Procedure for saving or deleting remote controls
-
RADIO CODE LEARNING to control full opening and closing of the gate, maximum capacity 50 remote controls.
N.B.:
The first saved remote control configures the control unit to accept only remote controls with a rolling code or only remote controls with a fixed 12-bit
code.
1. With the gate closed, press and hold the MEMO RX button
2. Transmit the channel of the remote control that you want to save, a blink of the flashing light will follow to confirm saving, release the MEMO RX button.
Repeat the procedure to save other remote controls, for a maximum of 50 remote controls
DELETING A REMOTE CONTROL
1. Press and hold the MEMO RX button until the flashing light comes on with a steady light.
2. Transmit the channel of the remote control that you want to delete, 2 blinks of the flashing light will follow to confirm deletion.
PROCEDURE FOR DELETING ALL REMOTE CONTROLS
1. Press and hold the MEMO RX button until the flashing light comes on steady
2. Continue keeping the button pressed until the flashing light starts blinking, after 10 blinks ALL the codes will be deleted
N.B.:
After deleting all the remote controls, the first saved remote control configures the control unit to accept only remote controls with a rolling code or only
remote controls with a fixed 12-bit code.
8 - Programmable functions:
The table shows the functions that can be activated via the dip switches, the control unit reads the position of the dip switches with the gate stationary on
closing:
Dip switch number Status of dip
switch
Description
DIP 1
OFF
Closes after photocell disengagement, not active
DIP 1
ON
The gate closes 2 seconds after photocell disengagement (PHC input), if the automatic closing function is active
DIP 2
OFF
Automatic closing function not enabled
DIP 2
ON
Automatic closing function enabled
DIP 3
OFF
P.P. and PED control function without stopping (open – close – open)
DIP 3
ON
P.P. and PED control function without stopping (open – close – open)
DIP 4
OFF
Condominium function not enabled
DIP 4
ON
Condominium function active (during gate opening, it is not possible to stop the movement with the remote control or the P.P.
and PED inputs, with the gate open with the automatic closing function active, if the P.P. input is closed the control unit stops
the count for automatic closing until the input is reset, used for connecting a coil or timer)
DIP 5
OFF
Slowdown distance equal to 10% of total travel
DIP 5
ON
Slowdown distance equal to 20% of total travel
DIP 6
OFF
PHO input configured for connecting the photocells on opening (when this input trips it stops the movement of the gate dur-
ing opening and during closing, until it disengages to then continue opening)
DIP 6
ON
PHO input configured for connecting the sensitive edge, when this input trips during opening and closing it causes reversing
by approximately 5 cm.
DIP 7
OFF
High speed during slowdown
DIP 7
ON
Low speed during slowdown
DIP 8
OFF
Photo-test function not active
DIP 8
ON
Photo-test function active (observe the wiring shown in point 4.5.3)