13
EAM2, EAM3
IT
10- Unlocking the actuator:
open the sliding door (A), insert the key, turn it anticlockwise (B) and remove the cover (C).
Turn the unlocking lever 180° anticlockwise.
With the actuator unlocked, manually simulate opening and closing completely. There must be no strong mechanical friction during this movement.
N.B.:
Check for the presence and tightness of the mechanical stops on both opening and closing. Should the gate leaf exceed a length of 2 metres it
is necessary to install the electrical lock.
Terminal number
Wire colour
Description
1
Unleaded
Encoder signal
2
White
Encoder supply voltage negative (GND)
3
Red
Encoder supply voltage positive (+12 Vdc)
4
Brown
Motor supply voltage (closing)
5
White
Motor supply voltage (opening)
The electrical wiring between the control unit and the actuator must not exceed 15 metres.
11- Electrical wiring harnesses:
Open the cover of the compartment for the electrical wiring harness, take out the terminal block and do the wiring according to the diagram:
C
B
A
1
2
3
4
5