Functions
Configurable parameters
Monostable relay
•
69PH identifier (see paragraph 4 “ID assignment”)
•
Operating modes = “DEFAULT”
•
Group 1 = 0
•
Group 2 = 0
•
Group 3 = 0
•
Group 4 = 0
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Call-activated monostable relay
•
Operating modes = “Monost.Call Accept.”
•
Enabling map = enable devices that send and receive the call (all enabled by default)
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Door lock command activated monos-
table relay
•
Operating modes = “Monost. On SR”
•
Enabling map = enable devices that send and receive the command (all enabled by default)
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Monostable relay activated by com-
mand F1
•
Operating modes = “Monost. On F1”
•
Enabling map = enable devices that send and receive the command (all enabled by default)
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Monostable relay activated by com-
mand F2
•
Operating modes = “Monost. On F2”
•
Enabling map = enable devices that send and receive the command (all enabled by default)
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Call attempt activated monostable relay •
Operating modes = “Call Att.Enabl.Map”
•
Enabling map = enable devices that send and receive the call (all enabled by default)
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Monostable relay activated by call at-
tempt to master unit
•
Operating modes = “Call Att.to Group”
•
Group 1 = ID indoor station
•
Group 2 = ID indoor station
•
Group 3 = ID indoor station
•
Group 4 = ID indoor station
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Button-activated bistable relay
•
69PH identifier (see paragraph 4 “ID assignment”)
•
Operating modes = “Bistable”
•
T1 activation delay time (def. 1s)
•
T2 deactivation delay time (def. 1s)
•
FLAG “State Not.” (YES = sends status with each switch, NO = does not send)
Bistable relay activated by accepted call. •
Operating modes = “Bist.Accept.Call”
•
Enabling map = enable devices that send and receive the command (all enabled by default)
•
T1 activation delay time (def. 1s)
•
T2 deactivation delay time (def. 1s)
•
FLAG “Int.Call” (YES = Deactivates at end of call. NO = Deactivates on answering or, if external call, at end of electronic unit chime cycles)
Call repeater
•
Operating modes = “Default”
•
Group 1 RL1 = Group 1 RL2 = ID indoor station
•
Group 2 RL1 = Group 2 RL2 = ID indoor station
•
Group 3 RL1 = Group 3 RL2 = ID indoor station
•
Group 4 RL1 = Group 4 RL2 = ID indoor station
•
“Chime cycles” = desired number of cycles
Generic call repeater
•
Operating modes = “Default”
•
Group 1 RL1;
Kind of call repeated for Group 1 RL1
•
Group 2 RL1;
Kind of call repeated for Group 2 RL1
•
Group 3 RL1;
Kind of call repeated for Group 3 RL1
•
Group 4 RL1;
Kind of call repeated for Group 4 RL1
•
Group 1 RL2;
Kind of call repeated for Group 1 RL2
•
Group 2 RL2;
Kind of call repeated for Group 2 RL2
•
Group 3 RL2;
Kind of call repeated for Group 3 RL2
•
Group 4 RL2;
Kind of call repeated for Group 4 RL2
•
“Chime cycles” = desired number of cycles
N.B. For repetition of calls from 6120, the “landing group” flag of the called indoor station must be enabled.
Call repeater from 6120
•
Operating modes = “Call Rep. 6120"
•
Enabling map = enable devices that send and receive the call (all enabled by default)
•
“Chime cycles” = desired number of cycles
Roller Shutter mode
•
Operating modes = “Roller Shutter Mode”
•
T1 delay time (def. 1s)
•
T2 activation time (def. 1s)
Call progression
•
Operating modes = “Call progression”
Table 6
7
EN
69PH