![Vimar Elvox 41017 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/vimar/elvox-41017/elvox-41017_installer-manual_1027423008.webp)
EN
Transponder reader for access control,
white LED backlighting, 1 input that can
be enabled for an additional push button,
1 NO relay output, to be completed with
front panel.
1. Description
The device allows access control and actuator control by
RFID card. Four possible operating modes, according to
type of installation:
standalone
,
slave-DueFili, eipvdes
(IP Video-Door Entry System), or
slave-eipvdes
. For
the
standalone
and
slave-DueFili
operating modes, the
management and update configuration software to be
used is SaveProg; for
eipvdes
and
slave-eipvdes
, Video
Door IP Manager is to be used. Once the
slave
mode has
been selected, the product is autonomously configured
in
slave-DueFili
or
slave-eipvdes
mode depending on
which panel it is connected to.
In
standalone
mode (factory default setting), recognition
of a previously registered card commands activation of
relay F1. It is also possible to enable input CA for the
connection of an additional push button and directly
command output F1. In this mode, SaveProg can be used
to register cards and configure the device.
In
slave-DueFili
mode, the device must be connected
to an electronic audio or audio/video module in the Pixel
2-wire series using specific wiring (connectors
f
or
g
).
The above description for
standalone
mode applies.
Alternatively, output F1 may be used to control any other
output (relay/lock) of the audio or audio/video module or
other auxiliary modules of the system.
In
eipvdes
mode, the device must be connected directly
(via RJ45 interface) to a network on which an Elvox IP
video door entry service is provided. Device programming
and configuration operations are performed using Video-
Door IP manager. Each registered card, and also input
CA, can be associated with activation of an actuator in
the video door entry system (including the local F1 relay).
Alternatively, CA can be configured as the sensor input
for the "door open" signal.
In
slave-eipvdes
mode, the device must be connected
to an electronic audio/video module in the Pixel IP series
using specific wiring (connectors
f
or
g
). The functional
characteristics, the programming and the configuration
operations are the same as described for the
eipvdes
mode.
In the factory default setting (
standalone
mode), the
device, if connected to an Elvox IP video door entry
system, can be identified and configured using Video-
Door IP Manager. Once the first configuration has been
completed, the operating mode will be set as
eipvdes
.
However, for the
slave-DueFili
and
slave-eipvdes
operating modes, slave mode must be specifically set
using SaveProg. SaveProg can be used at any time to set
one of the following modes:
standalone
,
slave
(
DueFili
or
eipvdes
) and
eipvdes
.
The device is compliant with the ISO 14443A/MIFARE
standard: MIFARE™ CLASSIC (1K e 4K), MIFARE
ULTRALIGHT™ (ULTRALIGHT EV1/ULTRALIGHT C)
and MIFARE DESFire™ (DESFIRE EV1 2K/4K/8K).
2. Characteristics
• Power supply:
1) from the electronic audio or audio/video module, via
specific wiring (
slave-DueFili
and
slave-eipvdes
modes);
2) from additional power supply unit on terminals 5V+
and 5V- (all operating modes);
3) Power-over-Ethernet Class 0 (IEEE 802.3-2012)
via RJ45 interface. NOTE: The RJ45 network
interface is to be connected exclusively to a SELV
(Safety Extra-Low Voltage) network. The Power-
over-Ethernet power supply unit (PSE) must
provide electrical insulation between any accessible
conductor including the earth wire, if there is one,
and all the contacts of the network ports, including
those not used by the PSE or by the device to be
installed (
eipvdes
mode).
• Maximum power consumption: 250 mA at 5V.
• Average PoE consumption: 2.5 W.
• Operating temperature: -25 °C / +55 °C.
• Degree of protection: IP54.
• Degree of protection against impact: IK08.
• Frequency range: 13.553-13.567 MHz
• RF transmission power: < 60 dBμA/m
• Operating distance: up to 1 cm.
• Compatible with Vimar programmable transponder card
(art. 01598).
3.
Standalone
and
slave-DueFili
modes
A maximum of 2000
user
or
administrator
cards can be
registered in total. The first type can be used to activate
the configured actuator, while the second can be used to
register new user card without having to use SaveProg
(manual registration).
By default, only the use of MIFARE CLASSIC 1K cards is
enabled. Using SaveProg, it is possible to enable the use
of other types of card.
3.1 Configuration
Connect the device to the PC using a USB cable. Refer
to the SaveProg documentation for specific details. It is
possible to:
•
Set the operating mode:
standalone, slave
or
eipvdes
.
•
Add and remove user and administrator cards.