Parameter default settings
Parameter
Default
Parameter
Default
1.0
Message language
Italian
3.5
Door Open send time
Disabled
1.1
Entrance panel ID
1
3.6
External volume
3
1.2
Installation
Vertical Bus
3.7
Internal volume
3
1.3
Initial ID (+)
1
3.8
Balancing
8
1.4
Final ID (+)
1000
3.9
Chime Volume
0
1.5
First button ID
1
3.10
Lock interlock
No
1.6
Button remapping
HW
3.11
Enabling
Direct enabled, Common disabled
1.7
Single buttons
Yes
4.0
Entrance panel chime
Yes
1.8
No. coding digits
Sequential coding
4.1
No. chime cycles
2
1.9
Lock code
R+1
4.2
Switchboard pb
Not assigned
2.0
Preferential code
Not assigned
4.3
Button Audio call
Not assigned
2.1
Preferential code
Not assigned
4.4
Com. lock
Not assigned
2.2
Lock codes
Not assigned
4.5
F1 common
Not assigned
2.3
F1 codes
Not assigned
4.6
F2 common
Not assigned
2.4
F2 codes
Not assigned
4.7
Disable SB search (*)
Yes
2.5
No. Dev. (
-)
Not assigned
4.8
Disable self-start (*)
No
2.6
Search all contacts
No
4.9
Seq. Self-start (*)
Not assigned
2.7
Contacts Name
Not assigned
4.10
Date and Time format
01/01/2014 00:00
2.8
Program Password
654321
5.0
Clock
01/01/13 00:00
2.9
Answer time
30 s
5.1
Enable timed codes
No
3.0
Conversation time
120s
5.2
First Time Call
0
3.1
Self-start time
10 s
5.3
Last Time Call
0
3.2
Lock time
1 s
5.4
Band
Not assigned
3.3
Function 1 Time
1 s
5.5
Device (°)
3.4
Function 2 Time
1 s
5.6
Button (°)
Notes:
(*) configurable only with MASTER or horizontal electronic unit, (°) only in the vertical configuration, (+) only in the horizontal configuration,
(-) only if No. Coding Digits is not
Sequential.
table 2
Parameter
configuration
Changes are made connecting one electronic unit at a time.
In systems with several electronic units, one unit must be identified as a
MASTER
and the other units as
SLAVE
units, regardless of model or type (alpha-
numeric, buttons, landing).
All entrance panels are supplied with the electronic unit set as
MASTER
(ID = 1).
Procedure for accessing parameter configuration mode
You have to start with the electronic unit in a state of rest: there must be no calls in progress, no self-starting or anything similar.
Press buttons
R
+
4
GHI
. Release the buttons.
Key in the password, by default
6
MNO
5
JKL
4
GHI
3
DEF
2
ABC
1
. Every time a button is pressed there will be a short “beep”, an asterisk “*” appears on the display,
and there are a further 25 s in which to press the next button. If you let the timeout elapse, the electronic unit
will return to rest.
After entering the password, press the
button. If the password is correct, the electronic unit goes into parameter configuration mode. If the password is
wrong, the electronic unit exits the procedure and reverts to at-rest status. The operation must be repeated.
Note:
The information that appears in square brackets refers to the case of active Horizontal Installation, paragraph 1.2.