33
EN
V7
N
0
+
3
DEF
V8
O
0
+
4
GHI
V9
P
0
+
5
JKL
V10
Q
0
+
6
MNO
V11
R
0
+
7
PQRS
V12
S
0
+
8
TUV
V13
T
0
+
9
WXYZ
V14
U
0
+
0
+
Note:
In the case of Horizontal installation, the prefix
H
indicates a Horizontal electronic unit, while
V
indicates one of
the vertical electronic units of the riser where there is the indoor unit. V15 does not exist, its function is performed by the
69RS. Cyclic self-starting is possible only on the first 16 horizontal electronic units. For the others, direct self-starting
is possible, after suitably programming the 69RS.
After the first
0
+
, or second
or
button, a symbol will appear indicating that another number key is expected.
A “clipboard” function can be used to help with duplication of the codes. When no symbol is shown as described above,
press
to record the sequence shown on the display. Select another device, access changes mode and press
to replace the existing sequence with the sequence recorded in the clipboard. Press
to confirm the change.
Note
: Each horizontal electronic unit can function as a Master (as regards self-starting) for the indoor units whose ID is
within the Initial ID - Final ID range (paragraph 1.3 and 1.4). It is enough for 69RS to have the Master entrance panel
of the riser remapped onto the current entrance panel.
Default: no sequence, so only the Master entrance panel (Vertical Installation) or the current one (Horizontal
Installation) is considered.
4.10 - DATE / TIME format
While awaiting selection, the electronic unit shows, among other information, the current date and time. The formats
in which they are shown are configurable. If desired, you can also delete one or both of them. Enter changes mode
with
, select the desired format with
or
, confirm with
. The time format is reached with
starting
from the date format.
Default: display date in the format day month / numeric month / 4-digit year, hour and minutes in 24H format
separated by ':', 01/01/2013 00:00:00.
5.0 - Clock
The clock must be set correctly for the service described in paragraphs 5.1 to 5.4 to be able to be correctly performed.
The date and time are retained for at least 2 days even with the electronic unit switched off. When the clock is first
powered up, or when the electronic unit remains switched off for longer than 2 days, the date is automatically set to 1
January 2013 and the time to 00:00. To adjust the date and time, press
. The modifiable field is indicated by a solid
rectangle to the right. To change the data for the day, enter numbers
0
+
..
9
WXYZ
with the keypad and to move on to
another field, use the
button to move right and
to move left. Confirm with
. If there is an error, for example
if the day is set any higher than 31, changes are rejected and the rectangle moves to the position of the error. There
is no need to enter the day of the week, as this will be calculated automatically from the date.
5.1 - Enable timed codes
This configuration enables the timed password function described under headings 5.2, 5.3 and 5.4. To enable press
1
. To disable press
0
+
.
Default: No
5.2 - First timed code
This configuration specifies the first code to be used for the Timed Codes function. Using buttons from
0
+
to
9
WXYZ
enter its number from 1 to 1000 or
0
+
to delete it. If the first code is higher than the second, or if one is programmed
and the other is not, a warning to check the other code is displayed. The valid codes are those in which the number
ranges from the first to the last as specified, excluding the limits.
Default: not programmed
5.3 - Last timed code
Like the code described above, but referring to the last valid code.
Default: not programmed
5.0
Clock
4.10
Date / Time format
5.1
Enabled time codes
5.2
First Call Time
5.3
Last call Time