31
EN
4.1
No. Chime cycles
4.0
Entrance panel chime
BUTTON
DISPLAY
DIRECT ACTION
COMMON ACTION
4
GHI
Sets to default the DIRECT
enabling of F2, ie
enables
them
Sets to default the COMMON
enabling of F2, ie
disables
them
5
JKL
Removes from default the DI-
RECT enabling of lock, F1, F2, ie
disables
all
Removes from default the COM-
MON enabling of lock, F1, F2, ie
enables
all
6
MNO
Removes from default the
DIRECT enabling of lock, ie
disables
them
Removes from default the COM-
MON enabling of lock, ie
enables
them
7
PQRS
Removes from default the DI-
RECT enabling of F1, ie
disables
them
Removes from default the COM-
MON enabling of F1, ie
enables
them
8
TUV
Removes from default the DI-
RECT enabling of F2, ie
disables
them
Removes from default the COM-
MON enabling of F2, ie
enables
them
9
WXYZ
Switches to
C
ommon. The first
letter of the second line becomes
C
.
Switches to
D
irect. The first letter
of the second line becomes
D
.
Default = direct commands enabled, indirect commands disabled
4.0 - Entrance panel chime repetition
Enables repetition of the chime in the speaker of the electronic unit. Press
1
to activate the chime; press
0
+
to
deactivate it. Press
to confirm the change.
Default = Yes
4.1 - Number of chime cycles
Following the transmission of a call, the electronic unit (see paragraph 4.0) and the indoor units emit a certain number
of chime cycles that can be selected with this setting. A chime cycle lasts for a total of 3 s (1 s chime, 2 s pause). Enter
the number of cycles with buttons
0
+
to
9
WXYZ
. Press the
button to confirm.
Default = 2
4.2 - Consumer unit button
R
For each of the 4 [8] configurable consumer units, you can choose a traditional button that makes a direct call to it.
Use the
and
buttons to choose the number of the consumer unit. Then key in the number of the button or
0
+
to cancel the program. Press the
button to confirm.
Default: not configured.
4.3 - Audio call button
R
This parameter enables configuring 8 IDs for receiving an audio call even if the signal is sent from a video electronic
unit. Use the
buttons to choose the location to be programmed, then buttons
0
+
to
9
WXYZ
to select the ID.
Press the
button to confirm.
Default: not configured.
4.4 - Common locks
R
This parameter allows indirect lock release, coinciding with the lock release of another electronic unit, controlled by
an indoor unit or a consumer unit, not by the local CA / M button. You can at the most associate indirect release with
8 different electronic units. Use the
and
buttons to choose the location to be programmed, then buttons
0
+
to
9
WXYZ
in order to enter a number between 1 and 15 [1 and 8248], that is the ID of an electronic unit, for controlling
the lock of which also the electronic unit being configured must enable its own. To confirm, press
. To cancel the
allocation, enter
0
+
as the ID.
Entering numbers between 21 and 36 [10001 and 16000], then the programmed element will not be an electronic
unit, but an operator or relay module. Number 21 identifies the 1st relay of the 1st operator. Unlike the lock, F1 or F2,
operators are not governed by any kind of disabling, as described under heading 3.11. For display purposes, entrance
panels have a letter "P" prefix, and operators a letter "A". The large numbers are essential in order to associate the
entrance panels or the relays of the vertical risers as they are seen in the horizontal bus.
Default: no association
4.2
Consumer unit button
4.3
Button Audio call
4.4
Com. lock