23
EN
sing the
R
button, or make a new one directly by keying in the new code
and confirming with
. You can also press one of the additional buttons
but in this case the entrance panel must have completed the chime cycles,
paragraph 4.1.
Engaged - Please Wait message
When the display shows:
the electronic unit is disabled for making calls, because another call is in
progress from an electronic unit located on the same bus. If during the mes-
sage
you try to make a call, the electronic unit will emit a long warning tone.
Mute chimes function (on indoor unit)
If a call is made to an indoor unit with the “chimes muted” function active,
the electronic unit will generate a beep through the loudspeaker and display
the message:
indicating that a call cannot currently be made to the user.
Self-start
If the self-start function is activated
from an indoor unit, the electronic unit
will display the message:
If a call is made in this situation, the effect will be to
cancel
the self-start
procedure
.
Door lock
release
from an
entrance panel
The lock of an electronic unit can be operated if at least one of the possible
1000 codes,
from 1 to 8 digits, is known beforehand. Before entering the
code digits, the preset access code must be entered, as described under
heading 1.4, default
R
+
1
.
In the meantime, the display shows the active buttons:
Enter all code digits:
Pressing
, the system checks whether or not the code already exists. If
it does, the local lock is activated. In the event of error, there is no warning.
If a mistake is made when entering data, press
R
and start again.
Opening
F1 from
entrance panel
Proceed as in the previous case, but the access code is
R
+
2
ABC
and is
not configurable.
Opening
F2 from
entrance panel
Proceed as in the previous case, but the access code is
R
+
3
DEF
and is
not configurable.
Note
: The procedures described above are possible only with the entrance
panel at rest, i.e. no calls, self-starting, or configurations in progress. Some
codes can be employed only during certain time bands. See paragraph 5.1.
Volume adjustment
YOU can adjust the external, internal, balance and chimes volume, during
a conversation and with no need to access the internal settings of the en-
trance panel. The adjustments can be made only after enabling the func-
tion, as described below.
- Press buttons
R
+
5
JKL
.
- When the following messages are displayed in alternation :
enter the parameter programming password; the default password is
6
MNO
5
JKL
4
GHI
3
DEF
2
ABC
1
.
- Every time a button is pressed there will be a short “beep”, an asterisk
“*” appears on the display, and there are a further 25 seconds (timeout)
in which to press the next button. If the timeout is allowed to elapse with-
out pressing any button, the electronic unit will exit programming mode.
After entering the password, press the
button to activate the func-
tion. If the password is correct, the electronic unit will briefly display the
message:
When the next call is made, the following messages appear cyclically on
the display:
When you answer, the following messages appear cyclically on the display:
If an indoor unit self-starts to this selfsame entrance panel you get to adjust
the external volume directly. Use the
buttons to raise or lower the
chosen level. To save the chosen level, press
. When the configuration
is saved the display will show:
Pressing the
button cycles through the adjustments of all the other
levels.
At the end of the conversation, which is terminated by replacing the handset
or when the conversation timeout elapses or if the
R
button of the elec-
tronic unit is pressed, the volume control function is cancelled.