background image

By-alarm

01729

Two-way radio frequency interface

SECURITY

Installer Manual

Содержание By-alarm 01729

Страница 1: ...By alarm 01729 Two way radio frequency interface SECURITY Installer Manual ...

Страница 2: ...2 ...

Страница 3: ...ervision operation 7 7 Signal strength 8 8 DIP switches and display messages 8 8 1 Functions of the DIP switches 8 8 2 Key to display messages 9 9 Operations on radio frequency detectors 9 9 1 Saving 9 9 2 Acquisition of art 01727 1 and 01728 10 9 2 1 Detector art 01727 1 10 9 2 2 Detector art 01728 with separate radio channels 11 9 3 Acquisition of art 01726 and 01731 11 9 4 Selective deletion 12...

Страница 4: ...le to extend the life of batteries by even up to 5 years 1 2 Technical characteristics Radio input lines 8 or 16 with single or double balancing pro grammable in all the modes contemplated by the control panel Connections with 4 conductors to one of the RS 485 serial ports as per control panel Instructions Power supply 12 V 20 Absorption with LEDs off 40 mA max with LEDs on 80 mA max Ambient condi...

Страница 5: ...bottom side using the holes making sure that they do not overlap it 2 1 Connection The radio interface with 8 or 16 input lines in a self protected plastic enclosure is connected to the control panel to one of the branches of the RS485 serial ports like any serial device following the instructions given in the control panel installation manual respecting their abbreviations So 2 conductors carry t...

Страница 6: ...01731 By alarm IP54 curtain radio frequency detector for outdoor use with dual technology to protect entrances and openings such as doors windows covered terraces corridors and French doors surface mounting powered by 1 3 V CR2 lithium battery supplied 4 Features of the radio interface The function of the radio interface is to receive data from multiple devices and send them to the control panel i...

Страница 7: ... tamper proof protections must be removed to make the protections active 4 3 Function LEDs On the board there are six LEDs and a display that shows the various states of the interface During normal operation the LEDs are off and the display cyclically shows the various associated devices In the event of an alarm and or malfunctioning of a device the interface will immediately display the number of...

Страница 8: ...the addresses previously assigned to other interfaces 01729 or input expansion modules 01709 and 01704 The addresses must be assigned in a sequential manner ie assigning ID 1 to the first device 2 to the second one and so on To address the interfaces carry out the following procedure a Power up the interface the display will show the symbol b Set DIP switch 5 to ON and the display will show Addres...

Страница 9: ...ntification code each single transmission is also interpreted as a survival message For obvious reasons the remote controls are not subject to supervision 6 1 How to program Supervision a Set the DIP switches 2 and 3 to ON and the display will show SU supervision b Press the SELECT button to display the state of supervision c Press the PROG button to deactivate NO or activate yes supervision d At ...

Страница 10: ...ent level 1 LED minimum level d At the end set the DIP switches 1 2 and 3 back to OFF 8 DIP switches and display messages 8 1 Functions of the DIP switches DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4 DIP switch 5 DIP switch 6 function off off off xxx xxx xxx Standard operation on off off xxx xxx xxx Delete contacts and sensors off on off xxx xxx xxx Delete Remote Controls on on off xxx xxx...

Страница 11: ...d to the inter faces 01729 and any input expansion modules 01709 and 01704 that may be present 9 1 Saving a Set the DIP switches 1 and 2 to ON the display will show i Installing Devices b Press the SELECT button to scroll through the free addresses on which to pair the devices c Run the procedure for installing the device refer to its installer sheet d If saving is successful the display will show...

Страница 12: ...nce If the detector has been programmed to use the IN input on separate radio channels go directly to the procedure described in para 9 2 1 for art 01727 1 and in para 9 2 2 for art 01728 If the detector has been programmed to use a single radio channel REED IN on the same channel for art 01727 1 press and release the SELECT push button to confirm the acquisition of the device and the three LEDs w...

Страница 13: ...ters by choosing to set them on separate channels the storage of each of these inputs will occupy a dedicated channel of the interface 01729 therefore according to the associated radio channel it will be assigned to a related zone in the system 9 3 Acquisition of art 01726 and 01731 Below is the general procedure for the acquisition of the detector 01726 the procedure is similar for detec tors 017...

Страница 14: ...confirm deletion and the display will show f Press the SELECT button to continue scrolling through the devices installed in the system g At the end set DIP switch 1 back to OFF 9 5 Total deletion a Set the DIP switch 1 to ON the display will show C Delete Devices b Press the SELECT button and the display will show u All c Press the PROG button for total deletion the display will show Ca Delete d P...

Страница 15: ...instruction sheet Prepare the radio interface for acquiring the device as per points a and b of subsection 9 1 Insert the battery in the remote control if not already inserted Press remote control buttons and together The LEDs inside the remote control will emit a short flash for a moment and will light up steady on the response of the radio interface Then continue from point d 10 3 Selective dele...

Страница 16: ...Controls b Press the SELECT button and the display will show u All c Press the PROG button for total deletion the display will show Ca delete d Press the PROG button to confirm deletion and the display will show e At the end set DIP switch 2 back to OFF By alarm Operations on remote controls ...

Страница 17: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 01729IEN 05 1907 ...

Отзывы: